engine AUDI A8 1999 D2 / 1.G AHA ATQ Engines Valve Gear User Guide
Page 37 of 62
15-31
Camshafts and camshaft adjusters,
removing and installing
Removing
- Remove engine cover (arrows).
Cylinder head installed Lock carrier in service position page 13
-1
- Remove ribbed belt page 13
-8 .
- Remove toothed belt page 13
-12
.
Left-side cylinder head - Remove noise insulation panel (arrows).
- Unbolt engine coolant expansion tank from bracket and lay aside.
- Remove crankshaft housing ventilation line from valve cover.
Pa
ge 37 of 62 Valve
gear, servicin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE03.15.1
Page 46 of 62
15-40
CAUTION!
After installing new hydraulic lifters, the
engine must not be started for approx. 30
minutes. The hydraulic valve lifters have to
settle (otherwise valves will strike the
pistons).
After installing the valvetrain and lifters,
carefully rotate the crankshaft by hand at
least 2 full revolutions before starting to be
sure that valves do not strike the pistons.
Sealing contact surfaces between bearing cap and cylinder head.
- Carefully apply a small amount of sealant D 454 300 A2 at four end
points of sealing surfaces on cylinder head (arrows) using small screw
driver.
- Install cylinder head cover.
- Install toothed belt page 13
-15
.
- Remove ribbed belt page 13
-8 .
Pa
ge 46 of 62 Valve
gear, servicin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE03.15.1
Page 51 of 62
15-45
Hydraulic valve lifters, checking
CAUTION!
After installing new hydraulic valve lifters the
engine must not be started for about 30
minutes. The hydraulic valve lifters must
settle (otherwise valves will strike pistons).
Then turn crankshaft two full revolutions by
hand before starting.
Notes:
Only replace hydraulic valve lifters in complete
sets. Hydraulic valve lifters cannot be adjusted
or repaired.
Irregular valve noise when starting engine is
normal.
- Start engine and let run until coolant
temperature reaches at least 80 C.
- Increase RPM to 2500 for about 2 minutes. If
necessary, test drive vehicle.
If hydraulic valve lifters are still loud, locate faulty
valve lifter as follows:
- Remove cylinder head cover.
Pa
ge 51 of 62 Valve
gear, servicin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE03.15.1
Page 60 of 62
15-52
Valve guides, checking
When servicing engines or cylinder heads with
leaking valves, refacing or replacing valve seats
and valves is not sufficient. Valve guides must be
checked for wear. This is especially important for
engines with high mileage.
Wear limit - Insert valve into guide.
Valve shaft edge must seal with guide. Due to differences in valve stem
diameter, make sure only intake valves are used to check intake
guides, and only exhaust valves are used to check exhaust guides.
- Measure axial play.Intake valve guide
Exhaust valve guide
0.8 mm (0.031 in.) 0.8 mm (0.031 in.) - If wear limit is exceeded, replace cylinder head.
Pa
ge 60 of 62 Valve
gear, servicin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE03.15.1