display AUDI A8 2000 D2 / 1.G ATQ Engine Oxygen Sensor Control Checking

Page 33 of 63

24-103


Display fields

1 2 3 4
Display group 043: Oxygen sensor aging, oxygen sensor behind catalytic converter (bank 1)
Display xxxx/min
xxx C
x.xxx V
---
Indicated Engine speed
(RPM) Exhaust
temperature Voltage of oxygen sensor
behind catalytic converter,
bank 1 Diagnostic condition
Functional
range 630 to 6800
RPM 70 to 850 C
0.100 to 1.000 volts Test OFF
Test ON
B1-S2 OK
B1-S2 not OK
Specified
value 1800 to 2400
RPM above 380 C 0.100 to 1.000 volts B1-S2 OK
Notes



If specified value is not obtained
Check oxygen sensor heater Page
24
-116

If specified value B1-S2 OK" is obtained:

- Press -C- button.

- Press buttons -0-, -4- and -4- to select "display
group number 044" and press -Q- button to
confirm input.
Pa
ge 33 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3

Page 34 of 63

System in Basic Setting 44
1
2
3
4

When indicated on display:
- Check specified value in display field 4 after indication "Test ON"
appears:
Pa
ge 34 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3

Page 35 of 63

24-104


Display fields

1 2 3 4
Display group 044: Oxygen sensor aging, oxygen sensor behind catalytic converter (bank 2)
Display xxxx/min
xxx C
x.xxx V
---
Indicated Engine speed
(RPM) Exhaust
temperature Voltage of oxygen sensor
behind catalytic converter,
bank 2 Diagnostic condition
Functional
range 670 to 6800
RPM 70 to 850 C
0.100 to 1.000 volts Test OFF
Test ON
B2-S2 OK
B2-S2 not OK
Specified
value 1800 to 2400
RPM above 380 C 0.100 to 1.000 volts B2-S2 OK
Notes



If specified value is not obtained
Check oxygen sensor heater Page
24
-116

If specified value B2-S2 OK" is obtained:

- Press -C- button.
Pa
ge 35 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3

Page 36 of 63

24-105

Checking oxygen sensor control behind
catalytic converter

- Perform a test drive of approx. 10 minutes.

WARNING!

Observe safety precautions to reduce the risk
of accidents during road test Page 24
-1 .

- Let engine continue to run at idle.Basic Setting
Q
Input displa
y group number XXX

When indicated on display:
- Press buttons -0-, -3- and -7- to select "display group number 037" and
press -Q- button to confirm input.
System in Basic Setting 37
1
2
3
4

When indicated on display:
- Check oxygen sensor voltage in display field 2.
- Check dwell time between oxygen sensor 1 before catalytic converter
and oxygen sensor 2 behind catalytic converter in display field 3 and
diagnostic result in display field 4.
Pa
ge 36 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3

Page 37 of 63

24-106


Display fields

1 2 3 4
Display group 037: Diagnostic, oxygen sensor control system (bank 1)
Display xxx % x.xxx volts
xxx ms
---
Indicated Engine
load Oxygen sensor voltage
behind catalytic
converter, bank 1 Oxygen sensor correction
value between oxygen sensor
1 and oxygen sensor 2, bank 1 Diagnostic condition
Functional
range 12.0 to
100.0 % 0.100 to 1.000 V
-800 to 800 ms
Test OFF
Test ON
System OK
System not OK
Specified
value 12.0 to
26.0 % 0.100 to 1.000 V
-800 to 800 ms System OK
Notes
If specified value is not
obtained: Evaluation
display field 2
Page 24
-109

If specified value is not
obtained Page 24
-110

If "System not OK" is displayed:
Check Diagnostic Trouble Code
(DTC) memory Page 01
-15

or continuation Page 24
-110

Note for display field 3:
The oxygen sensor control behind catalytic converter overrules the oxygen sensor control before catalytic converter. It
corrects slight changes in the mixture (i.e. toward rich or lean) due to the oxygen sensor before catalytic converter by holding
oxygen sensor control before catalytic converter at its higher or lower point for a specific time (dwell time). If this time is in the
positive range (i.e. 50 ms), mixture is shifted in the -enrich- direction. If this time is in the negative range (i.e. -50 ms), mixture
Pa
ge 37 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3

Page 39 of 63

24-107

- Press -C- button.

- Press buttons -0-, -3- and -8- to select "display
group number 038" and press -Q- button to
confirm input. System in Basic Setting 38
1
2
3
4

When indicated on display:
Note:
The test in display group 038 is activated simultaneously with the test in
display group 037 Therefore the test result is indicated immediately after
display group 038 is selected. - Check specified value in display field 4.
Pa
ge 39 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3

Page 40 of 63

24-108


Display fields

1 2 3 4
Display group 038: Diagnostic of oxygen sensor control system (Bank 2)
Display xxx % x.xxx V xxx ms
---
Indicated Engine
load Oxygen sensor voltage
behind catalytic converter,
bank 2 Oxygen sensor correction
value between oxygen sensor
2 and oxygen sensor 2, bank
1 Diagnostic condition
Functional
range 12.0 to
100.0 % 0.100 to 1.000 V -800 to 800 ms
System OK
System not OK
Specified
value 12.0 to
26.0 % 0.100 to 1.000 V -800 to 800 ms System OK
Notes
If specified value is not
obtained: Evaluation
display field 2 Page 24
-
109

If specified value is not
obtained Page 24
-110

If "SYST not OK" is displayed:
Check Diagnostic Trouble Code
(DTC) memory Page 01
-15

or continuation
Page 24
-110

Note for display field 3:
The oxygen sensor control behind catalytic converter overrules the oxygen sensor control before catalytic converter. It
corrects slight changes in the mixture (i.e. toward rich or lean) due to the oxygen sensor before catalytic converter by holding
oxygen sensor control before catalytic converter at its higher or lower point for a specific time (dwell time). If this time is in the
positive range (i.e. 50 ms), mixture is shifted in the -enrich- direction. If this time is in the negative range (i.e. -50 ms), mixture
is shifted in the -lean- direction.
Pa
ge 40 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3

Page 41 of 63

24-109
Evaluation of display group 037 and 038 Display field: 2
Possible cause
Corrective action
constant
about 0.450 V
Open circuit in wire 4 between oxygen sensor
and control module - Check primary voltage Page 24
-111


Open circuit in wire 3 between oxygen sensor
and control module
larger than
1.000 V Short circuit to B+ in wire 4 between oxygen
sensor and control module - Check oxygen sensor wiring and oxygen sensor
behind catalytic converter Page 24
-112

smaller than
0.150 V
Short circuit to Ground (GND) in wire 4 between
oxygen sensor and control module
Pa
ge 41 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3

Page 42 of 63

24-110

If specified value in display group 037 and
038 display field 3 or 4 is not obtained:

- Search for leaking air at exhaust system or
catalytic converter (check screw clamps and
exhaust system for damage).

- Check if possibly the oxygen sensors behind
catalytic converter of cylinder bank 1 and 2 have
been switched, in case of extremely different
values (e.g. +500 ms, - 500 ms) of display fields
3 (oxygen sensor correction value) in the
measuring value blocks 037 and 038.
If none of the listed causes applies:

- Replace respective oxygen sensor -before-
catalytic converter
Pa
ge 42 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3

Page 50 of 63

24-117

Note:
The heating circuit of the oxygen sensor is
monitored by On Board Diagnostic (OBD),
Check DTC memory Page 01
-15
.

- Connect VAS5051 tester or VAG1551 scan tool
and select the control module for engine
electronics using "address word" 01 Page 01
-
9 .

Engine must run at idle for this.Rapid data transfer
HELP
Select function XX

When indicated on display:
- Press buttons -0- and -8- to select "Read Measuring Value Block" and
press -Q- button to confirm input.
Read Measurin
g Value Block
Q
Input displa
y group number XXX

When indicated on display:
- Press buttons -0-, -4- and -1- to select "display group number 041" and
press -Q- button to confirm input.
Read Measuring Value Block 41
1
2
3
4

When indicated on display:
Note:
Increasing engine speed accelerates the obtaining of specified values. - Check specified values in display fields 1 and 3.
Pa
ge 50 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3

Page:   < prev 1-10 11-20 21-30 31-40 next >