lights BMW X5 2002 E53 Central Body Electronics User Guide
Page 61 of 64
GENERAL FUNCTIONS OF ZKE III
CONSUMER CUT OFF
The interior lights are connected to the consumer cut out circuit. These consumers are con-
nected to KL 30 and can remain on if one of the control switches are left on. This would
prevent the ZKE from going into the sleep mode. However, the consumer cut off will switch
Kl 30, to the interior lighting, off after 16 minutes.
OVERLOAD PROTECTION
The seat and steering column motors are provided operating power through the consumer
cutoff / overload protection relay module as on the E38. The consumer cutoff signal from
the GM signals the relay to maintain operating power to the consumers.
If an overload condition exists, the relay module detects the increase in amperage and
opens the relay. The relay module is located in the electrical carrier forward of the glove
box.