stop start BMW X5 2005 E53 M54 Engine Workshop Manual
Page 33 of 48
33
M54engMS43/ST036/6/20000
NOTE: With extremely hot oil temperatures Vanos is deactivated (Power loss). If the oil is
too thick (wrong viscosity) a fault could be set.
When the engine is started, the camshafts are in the “failsafe” position (deactivated). The
intake camshaft is in the RETARDED position - held by oil pressure from the sprung open
solenoid. The exhaust camshaft is in the ADVANCED position - held by a preload spring in
the actuator and oil pressure from the sprung open solenoid.
After 50 RPM (2-5 seconds) from engine start, the ECM is monitoring the exact camshaft
position.
The ECM positions the camshafts based on engine RPM and the throttle position signal.
From that point the camshaft timing will be varied based on intake air and coolant temper-
atures.
The double VANOS system is “fully variable”. When the ECM detects the camshafts are in
the optimum positions, the solenoids are modulated (approximately 100-220 Hz) maintain-
ing oil pressure on both sides of the actuators to hold the camshaft timing.
CAUTION:
The VANOS MUST
be removed and installed exactly as described in the Repair
Instructions!
NOTE: If the VANOS camshaft system goes to the failsafe mode (deactivated) there will be
a noticeable loss of power. This will be like driving with retarded ignition or starting from a
stop in third gear.
KL 15 KL 15
MS42.0
SOLENOID
OIL TEMP.
SENSOR TWO POSITION PISTON HOUSING
WITH INTERNAL/EXTERNAL
HELICAL GEAR CUP TWO POSITION PISTON
HOUSING WITH
INTERNAL/EXTERNAL
HELICAL GEAR CUP
ENGINE
OIL SUPPLY VENT VENT
SOLENOID
SENSOR SENSOR
MS42
ECMEXHAUST
INTAKE
MS42.0
ECM
MS 43.0
MS 43.0
MS 43.0