elect Citroen BERLINGO 2004 1.G Owners Manual

Page 485 of 523

Downloaded from www.Manualslib.com manuals search engine 481
ELECTRICAL
SYSTEM
CHARGING CIRCUIT ALTERNATOR WITH MONOFUNCTION REGULATOR
MINIMUM OUTPUTS (in A)
Alternator
speed
1800 rpm 11
27 39 46 61 73 89 108
2000 rpm 1234 46 54 68 80 105 123
3000 rpm 1347 60 68.5 84 100 139 164
4000 rpm 1455 65 75 92 110 145 176
6000 rpm15616978.5 96 120 151 183
8000 rpm 1663 70 80 97 123 157 188
15000 rpm1764738297124157188
Min.outputClass
6789121518
Alternator speed
1800 rpm
49 50 52 57 58 60 61
2000 rpm48 49 51 54 55 57 60
3000 rpm45464851525456
4000 rpm43 44 46 48 50 52 53
6000 rpm3940 42 43 48 50 50
8000 rpm26373940454848
15000 rpm24252729343838
Class
6789121518MINIMUM YIELDS (in %)

Page 486 of 523

Downloaded from www.Manualslib.com manuals search engine 482
ELECTRICAL
SYSTEMNAGARES 960411P
CARTIER 735068
NAGARES 960411P
CARTIER 735068
NAGARES 960411P
NAGARES 960411P
CARTIER 735068
NAGARES 960411P
NAGARES 960411P
CARTIER 735068
CARTIER 735068
NAGARES 960411P
CARTIER 735068
NAGARES 960411P
CARTIER 735068
NAGARES 960411P NGK YE04
NGK YE04
NGK YE04
BERU 0 100 226 371
CHAMPION CH 185
NGK YE04
CHAMPION CH170
CHAMPION CH 170
CHAMPION CH 170
PREHEATING AND STARTING SYSTEMSTOUS TYPES
Vehicles models
Preheater plugs Preheater control unitPre/Post heating (pre-heating duration at 20°C)
C2
C3
XSARA
PICASSO1.4 HDi
1.4 HDi
1.4 HDi 16V
1.9 D
1.4 HDi
2.0 HDi
2.0 HDi
2.0 HDi8HX
8HW
8HX
8HV
8HY
WJY
8HZ
RHY
RHZ
RHY
Controlled by the diesel injection ECU.
10s / 150s
Controlled by the diesel injection ECU.

Page 488 of 523

Downloaded from www.Manualslib.com manuals search engine 484
ELECTRICAL
SYSTEM
C5HP073C
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Clickfit connector removing/fitting tool
Ø Inch
V ehicle
XSARA
XSARA
PICASSOTT
BP
HP5/8Black
8005T.A
3/8Red
8005T.C Ring colour Tool kit 4164T
Tightening torques (m.daN).
Unions
Steel/Steel
Aluminium/Steel Ø Pipes
1,7 ±0,3
1,3 ± 0,3 M 06
3,8 ± 0,3
2 ± 0,2
M 08
4 ± 0,3
2,5 ± 0,3 M 10
NOTE:Tighten the union to the recommended torque using a retaining spanner whenever possible.
NOTE:For operations concerning draining, drying (empty), checking and recharging of a system:refer to BRE 0290.
WARNING: For R 134.a quantities (see table on preceding page:483).
Aircon compressor fixings.
ESSENTIAL: Tighten the front part of the compressor(timing belt end), before the rear part of the compressor.

Page 490 of 523

Downloaded from www.Manualslib.com manuals search engine 486
ELECTRICAL
SYSTEM
MANULLI calibrated seal (3).
Direction of fitting of the seal (3).
Before fitting the seal, amply lubricate the seal with air conditioningcompressor oil
(SP10). The condenser
(5)has a cylinder (6)incorporating the function of aircon
fluid reservoir and with integral filtering cartridge.The inlet
(7)and the outlet (8)of the condenser (5)are equipped with
new seals (3) (MANULLI).
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Seals (MANULLI seal)
Condenser (MANULLI seal)
C5HP18VDC5HP18XD
C2 C3 XSARA PICASSO

Page 492 of 523

Downloaded from www.Manualslib.com manuals search engine 488
ELECTRICAL
SYSTEM
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Pollen filter
Note:
The pollen filter is located in the engine compartment on the RH side.
Removing.
To remove:
Pull on the tab of the plastic cover (1), at «a».
Tilt the flap
(2).
Remove the pollen filter
(3).
Refitting.
Proceed in reverse order.
C4AP1BRCC4AP1BSCC4AP1BTC
C2

Page 493 of 523

Downloaded from www.Manualslib.com manuals search engine 489
ELECTRICAL
SYSTEM
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Pollen filter
Note:
The pollen filter is located in the engine compartment on the RH side.
Removing.
Remove:
The three screws (1).
The plastic cover (2).
Tilt the flap
(3).
Remove the pollen filter
(4).
Refitting.
Proceed in reverse order.
C4AP169CC4AP16ACC4AP16BC
C3 C3 PLURIEL

Page 510 of 523

Downloaded from www.Manualslib.com manuals search engine 506
ELECTRICAL
SYSTEM
AIR CONDITIONING SYSTEM R 134.a
Checks on the air conditioning circuit
C5HP1A8D
Key.
T/P
= Average temperature(°C ) at the air vents/
high pressure(Bars).
P
= Low pressure(Bars).
TE = Exterior temperature(C°).
HP = Pressure at compressor outlet (Bars).
BP = Pressure at compressor inlet(Bars).
TA = Average temperature(°C) of air blown from
the central vents.
C3 C3 PLURIEL BV MECANIQUE 8HX 8HW

Page 511 of 523

Downloaded from www.Manualslib.com manuals search engine 507
ELECTRICAL
SYSTEM
Plan of air conditioning system.
Two solutions:
1/ «MANULLI»
, with «NON EUROCLIM» compressor (Oring seals).
2/
«EATON», with «EUROCLIM»compressor (quadrilobe seals).
(1)High pressure valve.
(2)Low pressure valve.
(3)Pressostat.
(4)Dryer.
Tightening torques (m.daN).
(a): 0,8
(b):4 ± 0,4
(c) : 0,8
A
Right hand drive.
XSARA KFW NFU TU TT AIR CONDITIONING SYSTEM R 134.a
C5HP16RP