Valve Citroen BERLINGO 2004 1.G Workshop Manual

Page 516 of 523

Downloaded from www.Manualslib.com manuals search engine 512
Plan of air conditioning system.
Two solutions:
1/ «MANULLI»
, with «NON EUROCLIM»compressor (Oring seals).
2/ «EATON», with «EUROCLIM»compressor (quadrilobe seals).
(1)High pressure valve.
(2)Low pressure valve.
(3)Pressostat.
(4)Dryer.
Tightening torques (m.daN).
(a) : 0,8
(b):4 ± 0,4
(c):0,8
A
Right hand drive.
XSARA WJY RHYAIR CONDITIONING SYSTEM R 134.a
C5HP16TP
AIRCONAIRCON

Page 517 of 523

Downloaded from www.Manualslib.com manuals search engine 513
AIRCON
Plan of air conditioning system.
Three solutions :
1) «MANULLI»
, with «NON EUROCLIM»compressor (Oring seals).
2) «EATON», with «EUROCLIM»compressor and buffer capacity (quadrilobe seals).
3) «EATON», with «NON EUROCLIM»compressor and buffer capacity (Oring seals).
(1)High pressure valve
(2)Low pressure valve
(3)Buffer capacity.
Tightening torques (m.daN).
(a) : 0,8
(b):4 ± 0,4
(c):0,8
A
Right hand drive.
XSARA RHZ
AIR CONDITIONING SYSTEM R 134.a
C5HP17YP

Page 518 of 523

Downloaded from www.Manualslib.com manuals search engine 514
AIRCONAIRCON
Plan of air conditioning system.
Two solutions:
1/ «MANULLI»
, with «NON EUROCLIM»compressor (Oring seals).
2/ «EATON», with «EUROCLIM» compressor (quadrilobe seals).
(1)High pressure valve.
(2)Low pressure valve.
(3)Pressostat.
(4)Dryer.
Tightening torques (m.daN).
(a) : 0,8
(b):4 ± 0,4
(c):0,8
A
Right hand drive.
AIR CONDITIONING SYSTEM R 134.a
C5HP16UP
XSARA RHZ

Page 519 of 523

Downloaded from www.Manualslib.com manuals search engine 515
AIRCON
(1)High pressure valve
(2)Low pressure valve
(3)High pressure clickfit union (tool 8005-T.C)
(4)Low pressure clickfit union (tool 8005-T.A)
(5)Pressostat.: 1,8 ± 0,6 m.daN
(6)
Filtering/drying cartridge plug
Tightening torques (m.daN).
(a) : 0,8.± 0,1
(b) : 0,5.± 0,1(c):1,4 ± 0,2
(d):2,5 ±0,25
XSARA PICASSO NFV AIR CONDITIONING SYSTEM R 134.a
C5HP13PP

Page 520 of 523

Downloaded from www.Manualslib.com manuals search engine 516
AIRCONAIRCON
(1)High pressure valve
(2)Low pressure valve
(3)High pressure clickfit union (tool 8005-T.C)
(4)Low pressure clickfit union (tool 8005-T.A)
(5)Pressostat : 1,8 ± 0,6 m.daN
(6)
Filtering/drying cartridge plug
Tightening torques (m.daN).
(a) : 0,8.± 0,1
(b) : 0,5.± 0,1
(c) : 1,4 ± 0,2
HP/LP
compressor flange fixing:2,5 ±0,25
XSARA PICASSO 6FZ
AIR CONDITIONING SYSTEM R 134.a
C5HP13QP

Page 522 of 523

Downloaded from www.Manualslib.com manuals search engine 518
AIRCONAIRCON
(1)High pressure valve
(2) Low pressure valve
(3)High pressure clickfit union(tool 8005-T.C)
(4) Low pressure clickfit union (tool 8005-T.A)
(5)Pressostat : 1,8 ± 0,6 m.daN
(6)
Filtering/drying cartridge plug
Tightening torques (m.daN).
(a) : 0,8.± 0,1
(b) : 0,5.± 0,1
(c) : 1,4 ± 0,2
HP/LP
compressor flange fixing:4,2 ±0,15
XSARA PICASSO RHY RHZ
AIR CONDITIONING SYSTEM R 134.a
C5HP13RP

Page:   < prev 1-10 ... 71-80 81-90 91-100 101-110 111-120