cap Citroen BERLINGO 2004 1.G Repair Manual

Page 505 of 523

Downloaded from www.Manualslib.com manuals search engine 501
AIRCON
23 ± 2 22,5 ± 2 20 ± 2 17 ± 2 15,5 ± 2 14,5 ± 2
3,8 ± 0,2 3,6 ± 0,2 3,5 ± 0,2 3,1 ± 0,2 3 ± 0,2 2,9 ± 0,2
24,5 ±221,5 ±2 18,5 ± 2 17 ± 2 15,5 ± 2
4 ±0,2 3,8 ± 0,2 3,5 ± 0,2 3,2 ± 0,2 3 ± 0,2
21,5 ± 2 22,5 ± 2 20 ± 2 18 ± 2 16,5 ± 2 15,6 ± 2
3,2 ±0,23,3 ±0,23 ±0,22,8 ± 0,2 2,6 ± 0,2
25,5 ±320,5 ±318 ± 3 20 ± 3 13,5 ± 3 11 ± 3
4 ±0,33,5 ± 0,3 3 ± 0,3
25 ± 3 22,5 ± 3 20 ± 3 17 ± 3 15 ± 3
4 ±0,33,5 ± 0,3 3 ± 0,3
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM
Checking pressures
Tools. 1
charging station. 2thermometers.
Once the preliminary conditions, vehicle equipment and checks havebeen fulfilled
(see table). After the air conditioning has been on for
three minutes, record the following parameters: The temperature of the air coming from the central vents
(see table).
The High Pressure. The Low Pressure.
Compare the values recorded with the table below, or the graphs.
Ambient temperature in °C40 35 30 25 20 15
VehiclesEngines
XSARA
XSARA
PICASSOTU
EW
High pressure (Bars)
Low pressure (Bars)
Low pressure (Bars)
High pressure (Bars)
Low pressure (Bars)DWVehicle using R134.a fluid
(Compressor with variable capacity)
High pressure (Bars)
XSARA XSARA PICASSO
High pressure (Bars)
Low pressure (Bars)
High pressure (Bars)
Low pressure (Bars)
TU
EW
DW

Page 512 of 523

Downloaded from www.Manualslib.com manuals search engine 508
Plan of air conditioning system.
Solution:
1/ «EATON»
, with «EUROCLIM»compressor and buffer capacity (quadrilobe
seals)
.
(1)High pressure valve.
(2)Low pressure valve.
(3)Buffer capacity.
Tightening torques (m.daN).
(a):0,8
(b):4 ±0,4
(c) : 0,8
A
Right hand drive.
XSARA RFNAIR CONDITIONING SYSTEM R 134.a
C5HP17WP
AIRCONAIRCON

Page 515 of 523

Downloaded from www.Manualslib.com manuals search engine 511
AIRCON
Plan of air conditioning system.
Three solutions:1) «MANULLI»
, with «NON EUROCLIM»compressor (Oring seals).
2)«EATON», with «EUROCLIM»compressor and buffer capacity (quadrilobe seals).
3) «EATON», with «NON EUROCLIM»compressor and buffer capacity (Oring seals).
(1)High pressure valve.
(2)Low pressure valve.
(3)Buffer capacity.
Tightening torques (m.daN).
(a) : 0,8
(b): 4 ± 0,4
(c):0,8
A
Right hand drive.
XSARA WJY RHY
AIR CONDITIONING SYSTEM R 134.a
C5HP17XP

Page 517 of 523

Downloaded from www.Manualslib.com manuals search engine 513
AIRCON
Plan of air conditioning system.
Three solutions :
1) «MANULLI»
, with «NON EUROCLIM»compressor (Oring seals).
2) «EATON», with «EUROCLIM»compressor and buffer capacity (quadrilobe seals).
3) «EATON», with «NON EUROCLIM»compressor and buffer capacity (Oring seals).
(1)High pressure valve
(2)Low pressure valve
(3)Buffer capacity.
Tightening torques (m.daN).
(a) : 0,8
(b):4 ± 0,4
(c):0,8
A
Right hand drive.
XSARA RHZ
AIR CONDITIONING SYSTEM R 134.a
C5HP17YP