load capacity Citroen C2 2004 1.G Service Manual

Page 503 of 523

Downloaded from www.Manualslib.com manuals search engine 499
AIRCON
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM C3 C3 PLURIEL KFV
CHECKING TEMPERATURES (Continued)
Vehicle using R134.a fluid
(Compressor with variable capacity)
Ambient temperature in °C
Temperature
at the central
air vents
in °CEngines
V ehicle
C3
C3 PlurielKFV
22 ± 2 17,6 ± 2 14,4 ± 2 11,5 ± 2 7,6 ± 2 7,2 ± 2
NFU18,5 ± 2 15 ± 2 12,5 ± 2 10 ± 2 8,5 ± 2 6,5 ± 2
8HX 8HW22 ± 2 17,6 ± 2 14,4 ± 2 11,5 ± 2 7,6 ± 2 7,2 ± 2
TU18 ±217 ±214,5 ±211 ± 2 8,5 ± 2
8 ±2
EW19 ± 2 18 ± 2 15 ± 2 12 ± 2 10 ± 2
DW15 ±215,5 ±211 ± 2 9 ± 2 7 ± 2 5 ± 2
All types22 ±3 16 ± 3 12,5 ± 3 10 ± 3 8 ± 3 6,5 ± 3
XSARA
XSARA
PICASSO40 35 30 25 20 15

Page 504 of 523

Downloaded from www.Manualslib.com manuals search engine 500
26 ± 2 23,2 ± 2 21 ± 2 19,2 ± 2 15,3 ± 2 15 ± 2
4,3 ±2 3,4 ± 2 3,1 ± 2 2,8 ± 2 2,7 ± 2
25,2 ±223,6 ± 2 21,4 ± 2 20 ± 2 17,6 ± 2 14,5 ± 2
3,5 ± 2 3 ± 2 2,8 ± 2 2,5 ± 2 2,4 ± 2
26,2 ± 2 23,2 ± 2 21 ± 2 19,2 ± 2 15,3 ± 2 15 ± 2
4,3 ± 2 3,4 ± 2 3,1 ± 2 2,8 ± 2 2,7 ± 2
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM
Checking pressures
Tools. 1
charging station. 2thermometers.
Once the preliminary conditions, vehicle equipment and checks havebeen fulfilled
(see table). After the air conditioning has been on for
three minutes, record the following parameters: The temperature of the air coming from the central vents
(see table).
The High Pressure. The Low Pressure.
Compare the values recorded with the table below, or the graphs.
Ambient temperature in °C40 35 30 25 20 15
VehiclesEngines
C3
C3
C3 PlurielKFV
NFUHigh pressure (Bars)
Low pressure (Bars)
Low pressure (Bars)
High pressure (Bars)
Low pressure (Bars)8HX 8HWVehicle using R134.a fluid
(Compressor with variable capacity)
High pressure (Bars)
AIRCONAIRCON
C3 C3 PLURIEL XSARA XSARA PICASSO KFV

Page 505 of 523

Downloaded from www.Manualslib.com manuals search engine 501
AIRCON
23 ± 2 22,5 ± 2 20 ± 2 17 ± 2 15,5 ± 2 14,5 ± 2
3,8 ± 0,2 3,6 ± 0,2 3,5 ± 0,2 3,1 ± 0,2 3 ± 0,2 2,9 ± 0,2
24,5 ±221,5 ±2 18,5 ± 2 17 ± 2 15,5 ± 2
4 ±0,2 3,8 ± 0,2 3,5 ± 0,2 3,2 ± 0,2 3 ± 0,2
21,5 ± 2 22,5 ± 2 20 ± 2 18 ± 2 16,5 ± 2 15,6 ± 2
3,2 ±0,23,3 ±0,23 ±0,22,8 ± 0,2 2,6 ± 0,2
25,5 ±320,5 ±318 ± 3 20 ± 3 13,5 ± 3 11 ± 3
4 ±0,33,5 ± 0,3 3 ± 0,3
25 ± 3 22,5 ± 3 20 ± 3 17 ± 3 15 ± 3
4 ±0,33,5 ± 0,3 3 ± 0,3
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM
Checking pressures
Tools. 1
charging station. 2thermometers.
Once the preliminary conditions, vehicle equipment and checks havebeen fulfilled
(see table). After the air conditioning has been on for
three minutes, record the following parameters: The temperature of the air coming from the central vents
(see table).
The High Pressure. The Low Pressure.
Compare the values recorded with the table below, or the graphs.
Ambient temperature in °C40 35 30 25 20 15
VehiclesEngines
XSARA
XSARA
PICASSOTU
EW
High pressure (Bars)
Low pressure (Bars)
Low pressure (Bars)
High pressure (Bars)
Low pressure (Bars)DWVehicle using R134.a fluid
(Compressor with variable capacity)
High pressure (Bars)
XSARA XSARA PICASSO
High pressure (Bars)
Low pressure (Bars)
High pressure (Bars)
Low pressure (Bars)
TU
EW
DW

Page 512 of 523

Downloaded from www.Manualslib.com manuals search engine 508
Plan of air conditioning system.
Solution:
1/ «EATON»
, with «EUROCLIM»compressor and buffer capacity (quadrilobe
seals)
.
(1)High pressure valve.
(2)Low pressure valve.
(3)Buffer capacity.
Tightening torques (m.daN).
(a):0,8
(b):4 ±0,4
(c) : 0,8
A
Right hand drive.
XSARA RFNAIR CONDITIONING SYSTEM R 134.a
C5HP17WP
AIRCONAIRCON

Page 515 of 523

Downloaded from www.Manualslib.com manuals search engine 511
AIRCON
Plan of air conditioning system.
Three solutions:1) «MANULLI»
, with «NON EUROCLIM»compressor (Oring seals).
2)«EATON», with «EUROCLIM»compressor and buffer capacity (quadrilobe seals).
3) «EATON», with «NON EUROCLIM»compressor and buffer capacity (Oring seals).
(1)High pressure valve.
(2)Low pressure valve.
(3)Buffer capacity.
Tightening torques (m.daN).
(a) : 0,8
(b): 4 ± 0,4
(c):0,8
A
Right hand drive.
XSARA WJY RHY
AIR CONDITIONING SYSTEM R 134.a
C5HP17XP

Page 517 of 523

Downloaded from www.Manualslib.com manuals search engine 513
AIRCON
Plan of air conditioning system.
Three solutions :
1) «MANULLI»
, with «NON EUROCLIM»compressor (Oring seals).
2) «EATON», with «EUROCLIM»compressor and buffer capacity (quadrilobe seals).
3) «EATON», with «NON EUROCLIM»compressor and buffer capacity (Oring seals).
(1)High pressure valve
(2)Low pressure valve
(3)Buffer capacity.
Tightening torques (m.daN).
(a) : 0,8
(b):4 ± 0,4
(c):0,8
A
Right hand drive.
XSARA RHZ
AIR CONDITIONING SYSTEM R 134.a
C5HP17YP

Page:   < prev 1-10 ... 11-20 21-30 31-40 41-50