drain Citroen C3 2004 1.G Owner's Manual

Page 440 of 523

Downloaded from www.Manualslib.com manuals search engine 436
BRAKES
B3FP15XC
BLEEDING AND FILLING THE BRAKING SYSTEM
Tools.
[1]
Generic bleeding apparatus: «LURO» or similar.
Bleeding,refilling.
Draining.
Drain the brake fluid reservoir (1)to the maximum (if necessary, use a clean syringe).
Disconnect the connector (4).
Uncouple the pipe (2).
Unscrew the shaft (3).
Remove the reservoir (1).
Empty the brake fluid reservoir (1).
Clean the brake fluid reservoir (1).
Refit:
The brake fluid reservoir
(1).
The shaft (3).
Couple the pipe (2).
Reconnect the connector (4).
Filling the braking system.WARNING:Use only those hydraulic fluids that are approved and recommended.
Fill the brake fluid reservoir (1).
Bleeding the braking system.WARNING:During the bleeding operation, take care to maintain the level of brake fluid in the reser
voir and to top it up, using only brake fluid that is clean and clear.
C3 C3 PLURIEL

Page 462 of 523

Downloaded from www.Manualslib.com manuals search engine 458
BRAKESBLEEDING THE BRAKESXSARA PICASSO
Tools.Bleeding equipment of type «LURO» or similar.IMPERATIVE: For bleeding the secondary circuit, use ELIT, LEXIA or PROXIA diagnostic tools.
Draining.
Drain the brake fluid reservoir as empty as possible using a syringe.
Disconnect the brake fluid warning lamp connector.Retrieve the brake fluid reservoir from its supply pipes by pulling upwards.
Finish emptying the reservoir of brake fluid.
Clean the brake fluid reservoir.
Refit the brake fluid reservoir.
Reconnect the brake fluid warning lamp connector.
Filling.Refill the reservoir with brake fluid.WARNING:Use only the recommended hydraulic fluids.
Bleeding.
NOTE:Two technicians are required.
IMPERATIVE:During bleed operations, ensure that the level of brake fluid is maintained in the
reservoir and top it up, use only new brake fluid.
Bleed each wheel cylinder, proceeding in the following order:
Rear right hand wheel.
Front left hand wheel.
Rear left hand wheel.
Front right hand wheel.

Page 488 of 523

Downloaded from www.Manualslib.com manuals search engine 484
ELECTRICAL
SYSTEM
C5HP073C
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Clickfit connector removing/fitting tool
Ø Inch
V ehicle
XSARA
XSARA
PICASSOTT
BP
HP5/8Black
8005T.A
3/8Red
8005T.C Ring colour Tool kit 4164T
Tightening torques (m.daN).
Unions
Steel/Steel
Aluminium/Steel Ø Pipes
1,7 ±0,3
1,3 ± 0,3 M 06
3,8 ± 0,3
2 ± 0,2
M 08
4 ± 0,3
2,5 ± 0,3 M 10
NOTE:Tighten the union to the recommended torque using a retaining spanner whenever possible.
NOTE:For operations concerning draining, drying (empty), checking and recharging of a system:refer to BRE 0290.
WARNING: For R 134.a quantities (see table on preceding page:483).
Aircon compressor fixings.
ESSENTIAL: Tighten the front part of the compressor(timing belt end), before the rear part of the compressor.

Page 500 of 523

Downloaded from www.Manualslib.com manuals search engine 496
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Compressor lubricant
ESSENTIAL: The compressor lubricant is extremely hygroscopic; always use FRESH oil.
Checking the compressor oil level
There are three specific cases:
1/
Repairs to a system without leaks.2/Slow leak.3/Fast leak.
1/ Repairing a system without leaks.
a)Using draining/recovery equipment not fitted with an oil decanter.
Drain the system as slowly as possible via the LOW PRESSUREvalve, so as not to lose any oil.
No more oil should be added when filling the system with
R 134.a fluid.
b) Using draining/filling equipment fitted with an oil decanter. Drain the R 134.afluid from the system in accordance with the instructions in the equipment handbook.
Measure the amount of oil recovered.
Add the same amount of
NEWoil when filling the system with R 134.afluid.
c) Replacing a compressor. Remove the old compressor, drain it and measure the oil quantity.
Drain the new compressor (supplied full), so that the same amount of NEWoil is left in the compressor as was in the old compressor.
No more oil should be added when filling the system with R 134.afluid.
AIRCONAIRCON

Page 501 of 523

Downloaded from www.Manualslib.com manuals search engine 497
AIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Checking the compressor oil level (Continued)
2/ Slow leak.
Slow leaks do not lead to oil loss, therefore the same procedure should be followed as if there was no leak at all.
3/ Fast leak.
This type of leak causes both oil loss as well as allowing air to enter the system.
It is therefore necessary to:
Replace the dehydrator.
Drain as much oil as possible
(when replacing the faulty component).
Either before or during filling of the system with
R 134.afluid, introduce 80 ccof NEWoil into the system.