Engine Citroen C3 2004 1.G Workshop Manual

Page 501 of 523

Downloaded from www.Manualslib.com manuals search engine 497
AIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Checking the compressor oil level (Continued)
2/ Slow leak.
Slow leaks do not lead to oil loss, therefore the same procedure should be followed as if there was no leak at all.
3/ Fast leak.
This type of leak causes both oil loss as well as allowing air to enter the system.
It is therefore necessary to:
Replace the dehydrator.
Drain as much oil as possible
(when replacing the faulty component).
Either before or during filling of the system with
R 134.afluid, introduce 80 ccof NEWoil into the system.

Page 502 of 523

Downloaded from www.Manualslib.com manuals search engine 498
AIRCONAIRCON
AIR CONDITIONING SYSTEM R 134.a
Testing procedure
Conditions inside the vehicle.
Positions of the air conditioning controls:
Maximum cold.
Maximum blower power.
Air distribution on
«ventilation»with the air vents open.
Position the air inlet flap to outside air.
WARNING:For RFTA (1), disconnect the air inlet motor connector, first
ensuring that it is in the outside air position.
(1) RFTA= Fully automatic air conditioning.
Test procedure.When all these conditions are met, proceed in the following order:
Measure the temperature in the workshop approx. one metre in front of
the vehicle’s air inlet grille.
Start the engine
(without the air conditioning, or the blower, operating)and wait for the cooling fan slow speed to trigger (should the engine tem
perature not rise sufficiently, it is permissable to increase the engine
speed to 2000 rpm)
.
Once it is sufficiently hot in the engine compartment, return the engine
to idle and commence the test.Switch on the air conditioning and adjust the engine speed to
2500 rpm.
In an ambient temperature of 40°C, the engine speed will be brought
down to 2000 rpm, in order for the pressure safety threshold to cut off the
compressor.
For further temperatures/pressures: see Tables and Graphs on following
pages
221, 222 and 226.
After
3 minutesof operation, note down the following 3 parameters:
The temperature of the blown air coming out of the 2 central air vents
(take the average).
The high pressure, via the intermediary of the clickfit union (at the
pressure reducer inlet).
The low pressure, via the intermediary of the clickfit union (at the pressure
reducer outlet).NOTE:The low and high pressures are absolute pressures.
When measuring the blown air temperatures, avoid any contact between
the thermocouple and the air vents.
At the conclusion of the test involving vehicles with
«RFTA»
ALL TYPES

Page 503 of 523

Downloaded from www.Manualslib.com manuals search engine 499
AIRCON
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM C3 C3 PLURIEL KFV
CHECKING TEMPERATURES (Continued)
Vehicle using R134.a fluid
(Compressor with variable capacity)
Ambient temperature in °C
Temperature
at the central
air vents
in °CEngines
V ehicle
C3
C3 PlurielKFV
22 ± 2 17,6 ± 2 14,4 ± 2 11,5 ± 2 7,6 ± 2 7,2 ± 2
NFU18,5 ± 2 15 ± 2 12,5 ± 2 10 ± 2 8,5 ± 2 6,5 ± 2
8HX 8HW22 ± 2 17,6 ± 2 14,4 ± 2 11,5 ± 2 7,6 ± 2 7,2 ± 2
TU18 ±217 ±214,5 ±211 ± 2 8,5 ± 2
8 ±2
EW19 ± 2 18 ± 2 15 ± 2 12 ± 2 10 ± 2
DW15 ±215,5 ±211 ± 2 9 ± 2 7 ± 2 5 ± 2
All types22 ±3 16 ± 3 12,5 ± 3 10 ± 3 8 ± 3 6,5 ± 3
XSARA
XSARA
PICASSO40 35 30 25 20 15

Page 504 of 523

Downloaded from www.Manualslib.com manuals search engine 500
26 ± 2 23,2 ± 2 21 ± 2 19,2 ± 2 15,3 ± 2 15 ± 2
4,3 ±2 3,4 ± 2 3,1 ± 2 2,8 ± 2 2,7 ± 2
25,2 ±223,6 ± 2 21,4 ± 2 20 ± 2 17,6 ± 2 14,5 ± 2
3,5 ± 2 3 ± 2 2,8 ± 2 2,5 ± 2 2,4 ± 2
26,2 ± 2 23,2 ± 2 21 ± 2 19,2 ± 2 15,3 ± 2 15 ± 2
4,3 ± 2 3,4 ± 2 3,1 ± 2 2,8 ± 2 2,7 ± 2
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM
Checking pressures
Tools. 1
charging station. 2thermometers.
Once the preliminary conditions, vehicle equipment and checks havebeen fulfilled
(see table). After the air conditioning has been on for
three minutes, record the following parameters: The temperature of the air coming from the central vents
(see table).
The High Pressure. The Low Pressure.
Compare the values recorded with the table below, or the graphs.
Ambient temperature in °C40 35 30 25 20 15
VehiclesEngines
C3
C3
C3 PlurielKFV
NFUHigh pressure (Bars)
Low pressure (Bars)
Low pressure (Bars)
High pressure (Bars)
Low pressure (Bars)8HX 8HWVehicle using R134.a fluid
(Compressor with variable capacity)
High pressure (Bars)
AIRCONAIRCON
C3 C3 PLURIEL XSARA XSARA PICASSO KFV

Page 505 of 523

Downloaded from www.Manualslib.com manuals search engine 501
AIRCON
23 ± 2 22,5 ± 2 20 ± 2 17 ± 2 15,5 ± 2 14,5 ± 2
3,8 ± 0,2 3,6 ± 0,2 3,5 ± 0,2 3,1 ± 0,2 3 ± 0,2 2,9 ± 0,2
24,5 ±221,5 ±2 18,5 ± 2 17 ± 2 15,5 ± 2
4 ±0,2 3,8 ± 0,2 3,5 ± 0,2 3,2 ± 0,2 3 ± 0,2
21,5 ± 2 22,5 ± 2 20 ± 2 18 ± 2 16,5 ± 2 15,6 ± 2
3,2 ±0,23,3 ±0,23 ±0,22,8 ± 0,2 2,6 ± 0,2
25,5 ±320,5 ±318 ± 3 20 ± 3 13,5 ± 3 11 ± 3
4 ±0,33,5 ± 0,3 3 ± 0,3
25 ± 3 22,5 ± 3 20 ± 3 17 ± 3 15 ± 3
4 ±0,33,5 ± 0,3 3 ± 0,3
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM
Checking pressures
Tools. 1
charging station. 2thermometers.
Once the preliminary conditions, vehicle equipment and checks havebeen fulfilled
(see table). After the air conditioning has been on for
three minutes, record the following parameters: The temperature of the air coming from the central vents
(see table).
The High Pressure. The Low Pressure.
Compare the values recorded with the table below, or the graphs.
Ambient temperature in °C40 35 30 25 20 15
VehiclesEngines
XSARA
XSARA
PICASSOTU
EW
High pressure (Bars)
Low pressure (Bars)
Low pressure (Bars)
High pressure (Bars)
Low pressure (Bars)DWVehicle using R134.a fluid
(Compressor with variable capacity)
High pressure (Bars)
XSARA XSARA PICASSO
High pressure (Bars)
Low pressure (Bars)
High pressure (Bars)
Low pressure (Bars)
TU
EW
DW

Page 506 of 523

Downloaded from www.Manualslib.com manuals search engine 502
AIRCONAIRCON
(1)High pressure valve.
(2)Low pressure valve.
(3)Pressostat.
(4)Filter.
Tightening torques (m.daN).
(a) : 0,6
(b) : 0,6
(c) : 0,6
(d) : 0,6
(e):0,6
(f) : 0,7
C5HP19UP
C2AIR CONDITIONING SYSTEM R 134.a

Page 507 of 523

Downloaded from www.Manualslib.com manuals search engine 503
AIRCON
AIR CONDITIONING SYSTEM R 134.a
(1)High pressure valve.
(2) Low pressure valve.
(3) Filter.
(4)Pressostat.
Tightening torques (m.daN).
(a) : 0,6
(b) : 0,6
(c) : 0,6
(d) : 0,6
(e):0,6
(f) : 0,6
C5HP17SP
C3 C3 PLURIEL

Page 508 of 523

Downloaded from www.Manualslib.com manuals search engine 504
AIRCONAIRCON
AIR CONDITIONING SYSTEM R 134.a
Checks on the air conditioning circuit
C5HP1A5D
Key.
T/P
= Average temperature (°C)at the air vents/
high pressure (Bars).
P= Low pressure (Bars).
Te= Exterior temperature (C°).
HP= Pressure at compressor outlet (Bars).
BP= Pressure at compressor inlet (Bars).
TA = Average temperature (°C)of air blown from the
central vents.
C3 C3 PLURIEL BVA KFV

Page 509 of 523

Downloaded from www.Manualslib.com manuals search engine 505
AIRCON
AIR CONDITIONING SYSTEM R 134.a
Checks on the air conditioning circuit
C5HP18GD
Key.
T/P
= Average temperature(°C ) at the air vents/
high pressure(Bars).
P = Low pressure(Bars).
TE = Exterior temperature(C°).
HP = Pressure at compressor outlet(Bars).
BP = Pressure at compressor inlet(Bars).
TA = Average temperature(°C) of air blown from
the central vents.
C3 C3 PLURIEL NFV

Page 510 of 523

Downloaded from www.Manualslib.com manuals search engine 506
ELECTRICAL
SYSTEM
AIR CONDITIONING SYSTEM R 134.a
Checks on the air conditioning circuit
C5HP1A8D
Key.
T/P
= Average temperature(°C ) at the air vents/
high pressure(Bars).
P
= Low pressure(Bars).
TE = Exterior temperature(C°).
HP = Pressure at compressor outlet (Bars).
BP = Pressure at compressor inlet(Bars).
TA = Average temperature(°C) of air blown from
the central vents.
C3 C3 PLURIEL BV MECANIQUE 8HX 8HW