too low Citroen C3 2004 1.G Repair Manual

Page 442 of 523

Downloaded from www.Manualslib.com manuals search engine 438
BRAKES
B3FP160C
BLEEDING AND FILLING THE BRAKING SYSTEM (Continued)
With the bleeding apparatus.
Connect the bleeding apparatus [1]on the brake fluid reservoir (1).
Adjust the apparatus pressure to
2 Bars.
For each circuit:
Connect a transparent tube onto the bleed screw, submerge the other end of the tube in a clean container.
Open the bleed screw, wait until the fluid is flowing out without air bubbles.
Close the bleed screw.
Remove the bleeding apparatus
[1].
Check the brake fluid level
(should be between «MINI»level and «MAXI»level).
Fill if necessary with the approved and recommended synthetic brake fluid.
Without the bleeding apparatus.
NOTE:Two operators are necessary.
For each circuit:
Apply the brake pedal to place the circuit under pressure.
Connect a transparent tube onto the bleed screw, submerge the other end of the tube in a clean container. Open the bleed screw, wait until the fluid is flowing out without air bubbles.
Close the bleed screw.
Remove the tool
[1].
NOTE:Recommence the process a second time if that is necessary.
Check the brake fluid level
(should be between «MINI»level and «MAXI»level).
Fill if necessary with the approved and recommended synthetic brake fluid.
C3 C3 PLURIEL

Page 462 of 523

Downloaded from www.Manualslib.com manuals search engine 458
BRAKESBLEEDING THE BRAKESXSARA PICASSO
Tools.Bleeding equipment of type «LURO» or similar.IMPERATIVE: For bleeding the secondary circuit, use ELIT, LEXIA or PROXIA diagnostic tools.
Draining.
Drain the brake fluid reservoir as empty as possible using a syringe.
Disconnect the brake fluid warning lamp connector.Retrieve the brake fluid reservoir from its supply pipes by pulling upwards.
Finish emptying the reservoir of brake fluid.
Clean the brake fluid reservoir.
Refit the brake fluid reservoir.
Reconnect the brake fluid warning lamp connector.
Filling.Refill the reservoir with brake fluid.WARNING:Use only the recommended hydraulic fluids.
Bleeding.
NOTE:Two technicians are required.
IMPERATIVE:During bleed operations, ensure that the level of brake fluid is maintained in the
reservoir and top it up, use only new brake fluid.
Bleed each wheel cylinder, proceeding in the following order:
Rear right hand wheel.
Front left hand wheel.
Rear left hand wheel.
Front right hand wheel.

Page 504 of 523

Downloaded from www.Manualslib.com manuals search engine 500
26 ± 2 23,2 ± 2 21 ± 2 19,2 ± 2 15,3 ± 2 15 ± 2
4,3 ±2 3,4 ± 2 3,1 ± 2 2,8 ± 2 2,7 ± 2
25,2 ±223,6 ± 2 21,4 ± 2 20 ± 2 17,6 ± 2 14,5 ± 2
3,5 ± 2 3 ± 2 2,8 ± 2 2,5 ± 2 2,4 ± 2
26,2 ± 2 23,2 ± 2 21 ± 2 19,2 ± 2 15,3 ± 2 15 ± 2
4,3 ± 2 3,4 ± 2 3,1 ± 2 2,8 ± 2 2,7 ± 2
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM
Checking pressures
Tools. 1
charging station. 2thermometers.
Once the preliminary conditions, vehicle equipment and checks havebeen fulfilled
(see table). After the air conditioning has been on for
three minutes, record the following parameters: The temperature of the air coming from the central vents
(see table).
The High Pressure. The Low Pressure.
Compare the values recorded with the table below, or the graphs.
Ambient temperature in °C40 35 30 25 20 15
VehiclesEngines
C3
C3
C3 PlurielKFV
NFUHigh pressure (Bars)
Low pressure (Bars)
Low pressure (Bars)
High pressure (Bars)
Low pressure (Bars)8HX 8HWVehicle using R134.a fluid
(Compressor with variable capacity)
High pressure (Bars)
AIRCONAIRCON
C3 C3 PLURIEL XSARA XSARA PICASSO KFV

Page 505 of 523

Downloaded from www.Manualslib.com manuals search engine 501
AIRCON
23 ± 2 22,5 ± 2 20 ± 2 17 ± 2 15,5 ± 2 14,5 ± 2
3,8 ± 0,2 3,6 ± 0,2 3,5 ± 0,2 3,1 ± 0,2 3 ± 0,2 2,9 ± 0,2
24,5 ±221,5 ±2 18,5 ± 2 17 ± 2 15,5 ± 2
4 ±0,2 3,8 ± 0,2 3,5 ± 0,2 3,2 ± 0,2 3 ± 0,2
21,5 ± 2 22,5 ± 2 20 ± 2 18 ± 2 16,5 ± 2 15,6 ± 2
3,2 ±0,23,3 ±0,23 ±0,22,8 ± 0,2 2,6 ± 0,2
25,5 ±320,5 ±318 ± 3 20 ± 3 13,5 ± 3 11 ± 3
4 ±0,33,5 ± 0,3 3 ± 0,3
25 ± 3 22,5 ± 3 20 ± 3 17 ± 3 15 ± 3
4 ±0,33,5 ± 0,3 3 ± 0,3
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM
Checking pressures
Tools. 1
charging station. 2thermometers.
Once the preliminary conditions, vehicle equipment and checks havebeen fulfilled
(see table). After the air conditioning has been on for
three minutes, record the following parameters: The temperature of the air coming from the central vents
(see table).
The High Pressure. The Low Pressure.
Compare the values recorded with the table below, or the graphs.
Ambient temperature in °C40 35 30 25 20 15
VehiclesEngines
XSARA
XSARA
PICASSOTU
EW
High pressure (Bars)
Low pressure (Bars)
Low pressure (Bars)
High pressure (Bars)
Low pressure (Bars)DWVehicle using R134.a fluid
(Compressor with variable capacity)
High pressure (Bars)
XSARA XSARA PICASSO
High pressure (Bars)
Low pressure (Bars)
High pressure (Bars)
Low pressure (Bars)
TU
EW
DW

Page 519 of 523

Downloaded from www.Manualslib.com manuals search engine 515
AIRCON
(1)High pressure valve
(2)Low pressure valve
(3)High pressure clickfit union (tool 8005-T.C)
(4)Low pressure clickfit union (tool 8005-T.A)
(5)Pressostat.: 1,8 ± 0,6 m.daN
(6)
Filtering/drying cartridge plug
Tightening torques (m.daN).
(a) : 0,8.± 0,1
(b) : 0,5.± 0,1(c):1,4 ± 0,2
(d):2,5 ±0,25
XSARA PICASSO NFV AIR CONDITIONING SYSTEM R 134.a
C5HP13PP

Page 520 of 523

Downloaded from www.Manualslib.com manuals search engine 516
AIRCONAIRCON
(1)High pressure valve
(2)Low pressure valve
(3)High pressure clickfit union (tool 8005-T.C)
(4)Low pressure clickfit union (tool 8005-T.A)
(5)Pressostat : 1,8 ± 0,6 m.daN
(6)
Filtering/drying cartridge plug
Tightening torques (m.daN).
(a) : 0,8.± 0,1
(b) : 0,5.± 0,1
(c) : 1,4 ± 0,2
HP/LP
compressor flange fixing:2,5 ±0,25
XSARA PICASSO 6FZ
AIR CONDITIONING SYSTEM R 134.a
C5HP13QP

Page 522 of 523

Downloaded from www.Manualslib.com manuals search engine 518
AIRCONAIRCON
(1)High pressure valve
(2) Low pressure valve
(3)High pressure clickfit union(tool 8005-T.C)
(4) Low pressure clickfit union (tool 8005-T.A)
(5)Pressostat : 1,8 ± 0,6 m.daN
(6)
Filtering/drying cartridge plug
Tightening torques (m.daN).
(a) : 0,8.± 0,1
(b) : 0,5.± 0,1
(c) : 1,4 ± 0,2
HP/LP
compressor flange fixing:4,2 ±0,15
XSARA PICASSO RHY RHZ
AIR CONDITIONING SYSTEM R 134.a
C5HP13RP