remove evaporator Citroen C4 2005 2.G Workshop Manual
Page 447 of 462
Downloaded from www.Manualslib.com manuals search engine 441
AIR
CONDITIONING
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM
Interpretation of the measurements.
«m»:High pressure.«s»: Over-heating (SC).
«n»:High temperature.«t»:Ambient air temperature.
«p»:Under-cooling (SR).«u»:Blown air temperature.
«q»:Low pressure.«v»:Humidity.
«r»: Low temperature.«w»: Temperature T3.
Over-heating (SC).
The over-heating represents the difference between the aircon fluid temperature at the evaporator outlet
and the evaporation temperature.
The over-heating gives the quantity of aircon fluid (in the liquid state) in the air conditioning circuit
Values for over-heating (SC).
Values «s» Origins Solutions
2° < SC < 15°CCorrect quantity
SC > 15°CLack of aircon fluid in the cooling circuitAdd some
aircon fluid
SC < 2°CExcess aircon fluid in the cooling circuitRemove some
aircon fluid
Blown air temperature «u».
The blown air temperature should be between 2°Cand 10°C.
E5AP2FBC
Angl.-t2-page428-456-2005 9/01/06 10:25 Page 441