ABS DACIA SUPERNOVA 2004 Workshop Manual
Page 408 of 933
AIR CONDITIONING
62
62 - 1
GENERALITIES
GENERALITIES
The purpose of the a ir conditioning unit i s to produce a decrease of t he temperature in the
passengers compartment a nd to obtain a l ower value t emperature compared to the external
environment one, reducing in the same time the air moisture.
MAINTENANCE
For a vehicle equipped with air conditioning, it is recommended a frequent checking of the
refrigerating agent level. During the year it is recommended:
- the checking of the refrigerant fluid filling;
- the cleaning and the air-blowing of the condenser and the cooling radiator fins;
- the checking of the condensation removal pipe on order not to be clogged.
For important leakage repair, for any components replacement (compressor, condenser, etc)
and if moisture was noticed in t he air conditioning circuit, the dryer filter tank is to be replaced
and the unit draining is to be performed. The same is valid also in case the conditioning circuit
remains open without protection covers more than 10 minutes.
IMP ORTANT
Duri ng winter, it is recommended the frequent start of the system, in order to pro-
long the lifetime of the compressor and of the whole system.
The vehicle equipped with an air conditioning system shall be not exposed for more
than 20 minutes i n painting c abin where there are temperatures higher than 80 °C.
It is obligatory the use of the refrigerating agent and compressor oil type prescribed
by the manufacturer. It is absolutely forbidden to perform welding on the elements of the air condition
circ uits. The filling of the air conditioning system can be pe rformed only by m eans of charging
units and observing the instructions of the manufacturer. For mechanical or body
operations it is recommended pi ping protection in order to avoid their disconnection
by accident. Avoid the drip of the oil compressor on the painted vehicle body.
For component replacement implying the circuit draining, it is absolutely necessary
the use of new parts and of a special oil for compressor.
vnx.su
Page 412 of 933
AIR CONDITIONING
62
62 - 5
Basically, the air conditioning unit is formed of a closed circuit, composed by the following main
elem ents:
- ev aporator
- compre ssor
- c ondenser
- thermo static expansion valve
- conn ection pipes.
The evaporator is the component that ex t racts the heat from the passengers compartment and
is generally placed in the passengers compartment. In order to cool the passengers compartment
the hot air must be absorbed, the heat extracted and the “cooled” air redistributed. The hot air is
pa ssing through the evaporator to who is giving part of the temperature reducing so, its own
temperature. The cooled air is so conveyed in the passengers compartment, progressively reducing
the temperature.
In the same time, the refrigerant fluid which goes into the evaporator, is absorbing the heat, from
ai r pa ssing through the evaporator and at the same temperature, is transforming it from liquid into
va pors. At the evaporator exit, the refrigerant fluid is in vapor condition.
The evaporator is placed in the climate control unit and is protected by cases.
EVAPORATOR
EVAPORATOR CASES ASSEMBLY REPLACEMENT
DISMOUNTING
Disconnect the battery.
Drain the refrigerant circuit.
Dismount the sealing gaskets on the climate box outliner.
Dismount the thermostatic expansion valve.
Dismount the climate case locking plate.
Di sconnect the pipes evaporator – compressor and evaporator – tank filter.
Dismount the evaporator cases attachment nuts, on the right side.
Release the evaporator cases.
Replace the assembly .
vnx.su
Page 414 of 933
AIR CONDITIONING
62
62 - 7
The compressor is absorbing the vapors coming from the evaporator at low pressure and
temperature, is compressing them and convey the gas at high temperature and pressure. The refrigerant fluid in high pressure and temperature vapor condition is entering in the second
he at exchanger, which by condensation is transmitting the heat to the external environmental.
At the exit from the condenser, the refrigerant fl uid is in liquid condition, at a high pressure and temperature.
Type of compressor: SD 7Y15
Compressor oil : PAG SP 10 or SP20, volume –135 cmc.
Refrigerant: HFC 134 a, quantity of refrigerant : 0.590 kg
C OMPRESSOR REPLACEMENT
DISMOUNTING
Disconnect the battery.
Drain the refrigerant circuit.
Disconnect the compressor’s connection.
Disconnect the pipes from the compressor.
Dismount the belt tensioning screw and release the belt.
Dismount the compressor attachment screws.
Dismount the compressor.
Replace the compressor.
REMOUNTING
Perform in the reverse order the dismounting operations.
T ension the belt and tighten at the required moment the tightening attachment screw.
Fill the refrigerant circuit and check the good operation of the climate control system.
COMPRESSOR
vnx.su
Page 416 of 933
AIR CONDITIONING
62
62 - 9
PRESSURE CONTROLLER
(low pressure, high pressure, medium pressure, in accordance
with the specification) or pressure capture
- low pressure – disconnect when the pressure in the low pressure circuit is lower than
1,96 +/-0,2 bar , reestablishing at a higher pressure than 2,16 +/- 0,2 bar; - higher pressure – disconnect when the pressure in the high pressure circuit is higher than
31,4 +/-2 bar , reestablishing at a higher pre ssure than 25,5 +/-2 bar; - medium pre ssure - start s the bl ower on t he second level speed, when t he pressure i s
higher than 17,7+/-1bar and stops the blower at a lower pressure 13,7+/- 1,2.
Thermostatic expansion valve allows the reduction of the refrigerant liquid pressure which is
coming from t he condenser, passing through the tank filter and i s continuously adjusting the
refrigerant flow from the evaporator, to reach the compressor in vapor condition. PRESSURE CONTROLLER
The good operation of the air conditioning unit is ensured by a dryer filter tank that ha s the
purpose to protect the unit. The filter’s purpose is to absorb the eventually solid particles found
in the oil and refrigerant liquid circulation.
The interception is needed as they might block the operation of the thermostatic expansion
valve or may produce the compressor mobile parts worn or gripping.
DETECTION OF REFRIGERANT F LUID LEAKAGE
In order to detect the refrigerant liquid leakage, it is used a detector, calibrated to detect
leakage of 9gr. /year.
vnx.su
Page 417 of 933
AIR CONDITIONING
62
62 - 10
DRY
ER FILTER TANK
The dryer filter tank has a triple function in the air conditioning unit:
- filtering the refrigerant fluid from the unit;
- absorbing the moisture from the unit;
- it is a buffer storage tank of refrigerant fluid.
DRY ER FILTER TANK
REMOUNTING
Perform the dismounting operations in the reverse order.
Fill the refrigerant circuit, check the leakage and the good operation of the unit.
AT TENT ION
Do not mount dryer fi lter tanks that do not have protection covers. DRY
ER FILTER TANK REPLACEMENT
DISMOUNTING
Disconnect the battery.
Drain the refrigerant circuit.
Dismount the piping and protect the threads.
Disconnect the connector of the air conditioning pressure controller.
Dismount the receiver tank filter from the collar support.
Replace the tank filter.
vnx.su
Page 437 of 933
71
INTRENAL BODY TRIM
72 - 12
DISMOUNTING
Detach the attachment clips
(1) of the noise
absorbent pad (2) on the cowl panel.
Release the noise absorbent pad.
REMOUNTING
Per f o r m in the reverse order the
dismounting operations. C
OWL PANEL NOISE ABSORBENT
vnx.su
Page 502 of 933
82A
HORN - ENGINE IMMOBILISER
82A - 35
A
LP6. BLOCKING/UNLOCKING DOORS NOT OPERATING
RECOMMENDATION Check with the CLIP tester the absence of the failures.
If there are memorised failures, these must be removed.
Are the doors blocking mechanisms correctly
operating ?Repair the damaged mechanisms.No
Check the continuity a nd the isolation related to the ground
of the wiring between :
E.C.U . d ecoder pin B8 actuators
Pin B9 doors
Is the wiring in good condition?
Fix the wiring.No
Check the continuity a nd the isolation related
to the ground of the wiring between
E.C.U .pin B8 switch
d ecoder pin B9 blocking doors
Is the wiring in good condition?
Repair.
Di sconnect the E.C.U. decoder, then supply
the wiring connector with +12 V at pin B9 and
the ground at the pin B8, than versa (+ 12 V at
pin B8 and the ground at pin B9).
Ar e the actuators bl ocking/unlocking the
doors?
Damaged actuators.
Replace them.
Replace the E.C.U. decoder, then perform the “E.C.U. decoder replacement
procedure”. No
Yes
Yes
No
YesYes
AFTER REPAIRING Perform a conformity
checking.
Check the operation of the anti starting system.
DIAGNOSTIC
vnx.su
Page 503 of 933
82A
HORN - ENGINE IMMOBILISER
82A - 36
A
LP7. UNLOCKING DOORS NOT OPERATING BY RF REMOTE CONTROL
RECOMMENDATION Check the absence of failures with the CLIP tester.
If there are memorised failures, these must be repaired.
Are the states 11G and 11D ACTIVE when
the RF remote control is activated?S ee the treatment states 11G and
1 1D cf. Chapter “Diagnostic”.No
Check the fuse F15 ( up to 01.06.2001) or
F 07 (after 01.06.2001).
Is it good?
Replace the fuse.No
Yes
Yes
Activate the doors’ locking switch from t he
dashboard.
Are the doors blocking/ unlocking ? S
ee the treatment of the failure
“Doors blocking contact” and the
state 14 G cf. Chapter “Diagnostic”.
S ee ALP 6.
Yes
No
AFTER REPAIRING Perform a conformity checking.
Check the operation of the anti starting system.
DIAGNOSTIC
vnx.su
Page 504 of 933
82A
HORN - ENGINE IMMOBILISER
82A - 37
A
LP8. TURNING LIGHTS DO NOT SWITCH ON AT THE BLOCKING /
UNLOCKING OF THE DOORS
RECOMMENDATION Check the absence of the failures with the CLIP tester.
If there are failures, fix them first.
Check if the synchronisatio n of the RF remote control and the E.C.U. decoder has been performed .
Are the turning lights functioning normally at the activation of the signalling switch ?
Check the continuity and the isolation related to
the ground and the +12 V of the electric layout:
E.C.U. decoder FLASH relay
Pin B3 pole 2
Is it correct?
Repair the signalli ng system.
Check t he fuse F03 and F04.
Fix the electric layout.
Check the fuse F15 ( up to 01.06.2001) or
F 07 (after 01.06.2001).
Is it good?Replace the fuse.
Disconnect the FLASH relay. Supply with
+ 12, the pole 4 of the relay. Are the l eft
turning lights turning on? Supply with +12 V
the pole 5 of the signal relay.
Are the right turning lights turning on?
Repair the electric layout from
poles 4 and 5 of the FLASH relay.
Replace the FLASH relay.
AFTER REPAIRING Perform a conformity checking.
Check the operation of the anti starting system.
No
No
No
Yes
Yes
Yes
Yes No
DIAGNOSTIC
vnx.su
Page 505 of 933
82A
HORN - ENGINE IMMOBILISER
82A - 38
No
AFTER REPAIRING Perform a conformity
checking.
Check the operation of the anti starting system.
A LP9. THE CEILING LAMP DOES NOT SWITCH ON AT THE BLO CKING /
UNLOCKING OF THE DOORS OR IT REMAINS PERMANENTLY TURNED ON.
RECOMMENDATION Check the absence of failures with the CLIP tester.
If there are memorised failures, fix them first.
Check if t he doors are locked?
Has the ceiling lamp turned on? The ceiling lamp was in the
position “p
ermanently
lighting”. Normal
operation.Yes Yes
Unlock the doors with the RF remote control.
The ceiling is in the position “dome lighting”
Has the ceiling lamp turned on?
Check the isolation of the wiring
related to the ground on the line pinA1.
decoder ceiling
After 15 seconds, the ceiling lamp will
turn off.
Normal operation.
Was the E.C.U. decoder confi gured “With
dome ceiling ”?Configure the E.C.U. decoder with
the CLIP tester.
Check the continuity on the line
E. C.U. decoder pin A1 ceiling
Is the line good?Repair .
Check the ceiling lamp bulb.
No
No
No
Yes
Yes Yes
No
DIAGNOSTIC