Cooling - Radiator with electronic fan assemblyRadiator with electronic fan assemblyReplacement1. Discharge coolant (see Page 73).
2. Disassemble radiator water inlet hose [64000062].
3. Disassemble radiator water outlet hose [64000063].
4. Disassemble No.1 oil cooler inlet pipe (auto gear).
5. Disassemble No.1 oil cooler outlet pipe (auto gear).
6. Disassemble fixing clips of 2 wire harnesses from fan cover.
7. Remove mounting bracket assembly on radiator [64000058].
8. Remove radiator together with electronic fan assembly [64000057].
9. Remove electronic fan together with fan cover assembly [64000060].(a) Screw off fixed nuts connecting electronic fan together with fan cover assembly with radiator.
(b) Uncouple fan motor joint.
(c) Remove 2 bolts of fan.
(d) Remove fan motor at the same time.10. Replace and install as sequences opposite to the above.
11. Refill engine coolant (see Page 73).
12. Check there is leakage with coolant (see Page 66).
72

Page 84 of 419

CoolantReplacement1. Discharge engine coolant.Warning: when the temperature of engine and radiator is high, do not remove radiator cap to
avoid being scalded, because coolant and steam will spurt under high pressure.
(a) Remove radiator cap.
(b) Open radiator drain valve and engine drain valve.Cooling - Coolant2. Refill engine coolant.(a) Lock 2 drain valves and pour coolant into radiator until it is full.
Hints:Press radiator water inlet hose and outlet hose with hands several times.If coolant level is too low, please refill coolant again.
(b) Screw down radiator cap.
(c) Pour coolant into expansion tank until the level is up to “FULL” mark line.
(d) Run engine with vehicle warning up until thermostat valve is opened.
Hint:During vehicle warning up, press radiator water inlet hose and outlet hose with hands
several times.
(e) Engine flames out until coolant temperature falls to “cold”. Then open radiator cap and check coolant
level.
(f) If coolant level is too low, please perform the above steps again.
(g) If coolant level is not too low, please adjust expansion tank coolant level.3. Check there is leakage with coolant.(a) Refill engine coolant to radiator, and install radiator cap tester.
(b) Pressurize radiator to 118kPa, and check there is leakage.73Engine drain valve
Radiator drain valve Radiator cap
Drain pipe

Page 224 of 419

Air conditioner--Air conditioning system
Air conditioner
Air conditioning system
Note
1. Do not dispose Refrigerant in sealed space or near
flame.
2. Wear glasses to protect your eyes.
3. Do not let liquid Refrigerant contact with your eyes
or skin.
If liquid Refrigerant contacts with your eyes or skin:
(a) Wash the contacted part with much water.
Warning: do not knead your eyes or skin.
(b) Spread clean Vaseline on your skin.
(c) Go to doctor or hospital for special cure.
4. Forbid heating it or making it expose the flame.
5. Forbid dropping the Refrigerant tank or shake it
intensively.
6. Do not operate compressor when Refrigerant is lack.
If the Refrigerant in cooling system is lack, it will incur com-
pressor burned out for lacking lubrication. So it is necessary
to avoid.
7. Do not open the high pressure valve of filling instru-
ment package when compressor is working.
If opening the valve at this time, Refrigerant will flow back into
refrigerant tank to incur the tank will break. So only the low
pressure valve could be opened or closed.
8. Do not fill Refrigerant too much.
Too much refrigerant will make many problems such as lack
cooling degree, oil consumption, too hot engine and so on.
Inspection on automobile
1. Check the No.1 pressure switch.
(a) Control for electromagnetic clutch:
Check the function of pressure switch.
(1) Assembly filling instrument package.
(2) Connect the anode lead of OUM meter to No. 4 termi-
nal and connect cathode lead to No. 1 terminal.
(3) Liking that shown in figure. When refrigerant pressure
is changed, check the conduction between terminals.
wrong correct
Low-pressure
sideHigh-pressure
side
Not
conductionCon-
duction
Not
conduction
 213 

Page 225 of 419

Air conditioner--Air conditioning system
If resistance does not accord with the regulation, it is necessary to change heat sensitive resistance.
If the function does not accord with the regulation, it is
necessary to change pressure switch.
(b) Control for cooling fan:
Check the function of pressure switch.
(1) Connect the anode lead of OUM meter to No. 2 termi-
nal and connect cathode lead to No. 3 terminal.
(2) Liking that shown in left figure. When refrigerant pres-
sure is changed, check the conduction between
terminals.
If the function does not accord with the regulation, it is
necessary to change pressure switch.
Inspection
11
111..
...No.1 thermal resistor
(a) Check the resistance between No.1 terminal and No.2 ter-
minal of No.1 heat sensitive resistance at different
temperatures, liking that shown in figure.
Conduc-
tion Not conduc-
tion
 214 
Resistance:
--
---22
22255
555--
---11
11155
555--
---55
55555
55511
11155
55522
22255
55533
33355
55544
44455
55555
55555
55566
66655
55577
77755
55588
88855
555
11
11155
555
11
11100
00088
88866
66644
44422
222
22
22200
000
Resistance
Temperature

Page 227 of 419

(1) Refrigerant system with normal function.
Meter reading
Low pressure end:
0.15-0.25Mpa
High pressure end:
1.37-1.57Mpa
(2) Water in cooling system.
Air conditioner--Refrigerant
When cooling system is
working, the pressure in low
pressure end changes to
vacuum or normal periodically.Water vapor enters refrigerant
system, and freezes on the ex-
pansion valve, the system
stops cycle in short time, when
ice melts, it returns to normal
again.(1)Change the condenser.
(2)Remove water in pipeline
with method of taking out
vacuum repeatedly.
(3)Fill applicable new
refrigerant.zDryer locates at full humidity
state.
zWater vapor of refrigerant
freezes on the outlet orifice
of expansion valve to ob-
stacle freezing cycle.
Phenomenon Possible reason Diagnose Method
(3) Lack refrigerant
Situation: too cold periodically, then lose cooling degree.
zThe pressure of high and low
pressure end is low.
zThere is air bubble on
window.
zRefrigerant leaks.Some part of refrigerant system
leaks.(1)Check it with leakage
measurer, if necessary, re-
pair it.
(2)Fill refrigerant to applicable
quantity.
(3)If meter pressure reading is
0, after checking and repair-
ing leaking position, take out
vacuum.
zRefrigerant in system lacks.
zCooling degree is not
enough.
Phenomenon Possible reason Diagnose Method
State: lack refrigerant
 216 

Page 228 of 419

Air conditioner--Refrigerant
zThe pressure of high and low
pressure end is low.
zThe pipeline from condenser
to expansion valve frosts.
zRefrigerant flow in adjuster
is obstructed by impurity.zChange the condenser.zAdjuster is obstructed.
Phenomenon Possible reason Diagnose Method
State: cooling degree is not enough(4) Refrigerant cycle is poor
(5) Refrigerant does not have any cycle.
zLow pressure side is
vacuum, and pressure at
high pressure side is low.
zThe pipeline of front and
rear end of expansion
valve or adjuster frosts or
dews.
zRefrigerant flow in cool-
ing system is obstructed
by water vapor or dust.
zRefrigerant flow is ob-
structed by expansion
valve.(1)Check the expansion
valve.
(2)Remove the dirt in ex-
pansion valve with high
pressure air.
(3)Change condenser.
(4)Take out vacuum and fill
applicable refrigerant.
(5)If this is caused by ex-
pansion valve leakage,
change the valve. Refrigerant does not flow.
Phenomenon Possible reason Diagnose Method
State: not cool (sometime cool)
 217 

Page 229 of 419

Air conditioner--Refrigerant
zThe pressure of high and
low pressure end is high.
zThere is no bubble on
window when engine
speed decreases.
zToo much refrigerant in
system incurs this.
zHeat dispersion of con-
denser is bad.(1)Clean the condenser.
(2)Check the function of
cooling fan.
(3)If those two items above
are normal, check the re-
frigerant quantity. Fill
applicable refrigerant.
zFilled refrigerant is too
much.
zHeat dispersion of con-
denser is bad¡ú¡ú
¡ú¡ú
¡úheat dis-
persion sheet of con-
denser is obstructed or fan
engine has malfunction.
Phenomenon Possible reason Diagnose Method
State: cooling degree is not enough.
zThe pressure of high and
low pressure end is high.
zPipeline of low pressure
end is too hot to contact.
zThere is bubble on
window.Air enters cooling system. (1)Check whether the Re-
frigerant oil is too dirt or
lack.
(2)Take our vacuum and fill
new refrigerant.
zThere is air in cooling
system.
zIt does not take out
vacuum completely.
Phenomenon Possible reason Diagnose Method
State: cooling degree is not enough.(6) Refrigerant is too much or the radiating fin of condenser is bad
(7) Air enters cooling system
Note: i f cooling system is
opened, and it does not
take out vacuum when
filling refrigerant, this
state will happen.
 218 

Page 230 of 419

Air conditioner--Refrigerant
zThe pressure of high and low
pressure end is high.
zPipeline of low pressure end
frosts or dews heavily.Expansion valve has
malfunction.Check the expansion valve. zRefrigerant in low pressure
pipeline is too much.
zOpen degree of expansion
valve is too big.
Phenomenon Possible reason Diagnose Method
State: cooling degree is not enough
zThe pressure of low pressure
end is too high.
zThe pressure of high pres-
sure end is too low.There is inner leakage in
compressor.Repair or change the
compressor. zCompressor is bad.
zExpansion valve leaks or
sliding part is damaged.
Phenomenon Possible reason Diagnose Method
State: not cool(8) Expansion valve is bad
(9) Not cool
 219 

Page 232 of 419

Change
1. Reclaim HFC-134a (R134a)
(a) Turn A/C switch to ON.
(b) Keep the engine speed at 1000 rpm, and rotate cooling compressor for 5 to 6 minutes to make
refrigerant cycle, this could collect the Refrigerant oil in each part in cooling compressor as possible.
(c) Extinguish the engine.
(d) Drain the refrigerant.
2. Fill refrigerant
(a) Use vacuum pump to take out vacuum.
(b) Fill the refrigerant HFC-134a (R134a)
Standard quantity: 660 ± 10g
3. Heat the engine
4. Check whether the refrigerant leaks.
Air conditioner--Refrigerant
 221 
Bubble
disappearing
pointToo much filling refrigerant Increase 100g Filling quantity of refrigerant
Pressure at
the high
pressure side
Refrigerant quantity
Auxiliary condenser system
Applicable
filling scope

Page 244 of 419

57. Assemble control cable of air mixing flow choke
(manual air conditioner).
(a) Connect control cable of air mixing flow choke to air condi-
tioner control assembly.
(b) Set up drag arm at “MAX>COOL” position.
(c) Assemble inner pull cable terminal to control lever.
(d) Press down lightly the fixed clamp of pull cable by the ar-
row direction in left figure, then assemble exterior pull cable
to fixed clamp.
Air conditioner--Air conditioner central heating core assembly
Connection Clearance Wrong
 233 
Hint:Operate temperature control lever, check whether the control lever keep silent and does
not return at the position of “MAX.COOL” and “MAX.HOT”.
(e) Disassemble control cable of air mixing flow choke from air conditioner control assembly.
58. Assemble upper panel assembly.
59. Assemble air conditioner control assembly.
60. Assemble helix cable.
61. Assemble steering wheel.
62. Check whether the steering wheel position is right.
63. Check horn button assembly.
64. Assemble horn button assembly.
65. Check SRS warning light.
66. Assemble refrigerant No.1 low pressure hose.
(a) Spread Refrigerant oil on new O-shape loop and assemble
it on hose.
(b) Assemble refrigerant No.1 low pressure hose and fixed
clamp.
Hint:After installation, check the fixed situation of
pipeline fixed clamp claw.
67. Assemble refrigerant liquid pipe A.
(a) Spread Refrigerant oil on new O-shape loop and assemble it on hose.
(b) Assemble refrigerant liquid pipe A and fixed clamp.
Hint: After installation, check the fixed situation of pipeline fixed clamp claw.
68. Add cooling water.
69. Heat the engine.
70. Check whether the cooling water leaks.
71. Fill the refrigerant, regulated quantity: 660 ± 10g.
72. Check whether the refrigerant leaks.