air condition GREAT WALL SO COOL 2006 Owner's Manual

Page 349 of 484

BE-71
Cab wire harness

1 right front turn lamp
2 outdoor temperature sensor
3 right lever-shaped lamp
4 front fog lamp
5 horn
6 accumulator wire of 220V
7 electromagnetic fan
8 temperature control switch
9 protective box II
10 turn signal lamp on right side
11 brush motor
12 plug of engine wire harness
13 wire harness at right rear door
14 plug of frame wire harness
15 door lamp switch
16 wire harness at right front door
17 door lamp
18 right external electric rear vision mirror
19 protective box III
20 indoor temperature sensor
21 right loudspeaker22 speed-adjusting resistance
23 air blower
24 grounding wire
25 A/C switch
26 controlling element
27 ashtray lamp
28 receiver wire
29 cigarette lighter
30 cigarette lighter
31 rear sound box wire
32 amplifying plate of air-conditioner
33 grounding wire
34 heat-sensitive resistance
35 dual flasher switch
36 fog lamp switch
37 temperature indicator
38 combined switch shell lamp
39 combined switch
40 ignition switch
41 combination instrument A
42 combination instrument B43 parking brake switch
44 brake switch
45 left loudspeaker
46 control case of central control lock
47 grounding wire
48 grounding wire
49 voltage regulator
50 brake liquid level alarming device
51 protective box I
52 plug of wire harness at left rear door
53 door lamp
54 door lamp switch
55 ceiling lamp
56 lamp for reading
57 door lamp
58 door lamp switch
59 backup radar screen
60 right rear loudspeaker
61 highly-mounted stop lamp
62 left rear loudspeaker
1
2
34
5 6
789 10111213
14
15
16
17
18
19
20
2122
23
2425
26
27
28
29 30313233
34
35
36
373839
40
41
4243
4445
4647
48
4950
5152 53
54
55
56
5758 59
60
61
62
Body Electric SystemWire Harness Distribution

Page 350 of 484

BE-72
pi=ph
1 grounding wire
2 wire harness at right front door
3 warm air motor
4 wire harness at right front door
5 control case of central control lock
6 heat-sensitive resistance
7 speed-adjusting resistance
8 connected to housing wire harness
9 connected to housing wire harness
10 A/C switch
11 air-volume switch
12 ashtray luminous lamp
13 ECU
14 receiver
15 rear loudspeaker
16 cigarette lighter
17 cigarette lighter grounding wire
18 cigarette lighter luminous lamp
19 fog lamp switch
20 dual flasher switch21 luminous lamp on air-conditioner panel
22 combined switch
23 instrument
24 instrument
25 stop lamp switch
26 connected to roof wire harness
27 connected to housing wire harness
28 connected to housing wire harness
29 connected to housing wire harness
30 connected to wire harness at left front door
31 connected to wire harness at left front door
32 connected to wire harness at left front door
33 protective box I
34 grounding wire
35 wire harness at left front door
36 connected to wire harness at left rear door
37 parking brake switch
38 connected to wire harness at right rear door
39 right front door lamp switch
40 connected to chassis wire harness
1
2
3
4
5
6
7
8
910
11
12
13 14
1516
17
18 19
20
21
2223
24
25
26
27
28
2930
31
32
33
343536 37 38
39
Cab Wire harness (continued)
40
Body Electric SystemWire Harness Distribution

Page 351 of 484

BE-73
SY SJ
1 grounding wire
2 wire harness at right front door
3 warm air motor
4 connected to wire harness at right front door
5 control case of central control lock
6 electric aerial
7 heat-sensitive resistance
8 speed-adjusting resistance
9 connected to housing wire harness
10 connected to housing wire harness
11 A/C switch
12 air-volume switch
13 ashtray luminous lamp
14 grounding wire
15 ECU
16 CD device
17 CD device
18 cigarette lighter
19 cigarette lighter grounding wire
20 cigarette lighter luminous lamp
21 combined switch
22 fog lamp switch
23 dual flasher switch
24 rear defroster switch
25 rear brush switch
26 rear washer switch27 combination instrument
28 combination instrument
29 stop lamp switch
30 roof wire harness
31 connected to housing wire harness
32 connected to housing wire harness
33 connected to housing wire harness
34 connected to wire harness at left front door
35 connected to wire harness at left front door
36 connected to wire harness at left front door
37 protective box
38 rear defrost relay
39 connected to wire harness of rear air-conditioner
40 grounding wire
41 parking brake switch
42 connected to chassis wire harness
43 wire harness at right rear door
44 right front door lamp switch
45 right rear loudspeaker
46 rear washer motor
47 connected to wire harness at tail door
48 left front door lamp switch
49 wire harness at left rear door
50 left rear loudspeaker
51 standby power seat
1
2
3
4
5
6
7
8
9
101112
13
14
15
1617
181920
21 22232425262728
29
30
31
32
3334
35
36
37
38
39
4041 4243 444546
47
48495051
Cab wire harness (continued)
Body Electric SystemWire Harness Distribution

Page 358 of 484

BE-80
Wire harness at tail door and of rear air-conditioner
SY SJ
wire harness of rear
air-conditionerwire harness
of rear brush
1
2
3456
7
8V 10 1112 13
NQ
Only the vehicle with SY model has the wire harness of rear air-conditioner shown in above-mentioned wire harness.
1 rear A/C switch
2 connected to cab wire harness
3 rear air-conditioning relay
4 grounding wire
5 temperature control switch
6 electromagnetic valve
7 temperature controller8 speed-adjusting resistance
9 license lamp
10 license lamp
11 rear brusher motor
12 defroster
13 defroster
14 connected to cab wire harness
Body Electric SystemWire Harness Distribution

Page 364 of 484

AC-1
Page
Introduction ................................................................. AC-2
Electric circuit diagram of air-conditioning system ...... AC-4
System constitutes ...................................................... AC-8
General introduction .................................................... AC-9
Troubleshooting .......................................................... AC-10
Inspection for refrigerant quantity ................................ AC-11
Compressor ................................................................. AC-12
Liquid container ........................................................... AC-14
Condenser ................................................................... AC-15
Cooling device ............................................................. AC-16
Refrigerant pipeline ..................................................... AC-20
AC
Air-conditioning System

Page 365 of 484

AC-2Air Conditioning SystemIntroduction
In case the liquid refrigerant enters into the eye or touches the
skin, the following measures shall be taken:
Wash the part where is touched by the refrigerant with a
great deal of water.
Coat the skin with the clean Vaseline.
See the doctor or go to the hospital for treatment; and
Do not try to cure it yourself.
General Introduction
1. Take notice when handling refrigerant General Introduction
(a) Do not handling with refrigerant in the closed room or
near to open fire.
(b) Safety goggles shall be worn when handling
(c) Be careful to avoid the liquid refrigerant from entering
into your eye or touching you skin.
waterair
dust
ÅçåÇÉåëÉêplug
2. Take notice when changing the parts of refrigerant pipes:
(a) The refrigerant shall be exhausted gradually before
changing.
(b) The dismantled parts shall be covered with plug right
away so as to prevent the water or dust from entering into
the system.
(c) Do not store the condenser or liquid tank under the
condition that the plug has been uncovered. and
(d) Refrigerant shall be exhausted before installing the new
condenser, because the refrigerant, if not exhausted, will
eject out in gaseous form with the lubricant oil when the
plug is moved away.
3. Take notice when fastening the connection parts:
(a) Spread a little lubricant oil at the matching position of the
O-type ring to fasten the connection and avoid of gaseous
refrigerant leakage.
(b) Fasten the nut with two spanners so as to avoid of the pipe
deformation.

Page 366 of 484

AC-3Air Conditioning SystemIntroduction
(c) Tighten the O-ring matching position or the threaded position
to the specified moment.
4. Take notice when connecting measuring meter at branch pipes:
(a) Connect the end of filling hose with high speed joint to the
filling valve of compressor.
(b) Letter D marked on the compressor near the auxiliary valve
represents the side of high voltage while S means the side of
low voltage, which shall be looked out when connecting the hose.
(c) Fasten the bolts by hand, and
(d) In order to prevent the hose from loosing, lubricant oil shall not
be spread at the connection position.
Remarks: after connecting the measuring meter on branch pipes to
the refrigerant container (repairing tank), the air in the hose shall be
exhausted up.
5. Take notice when vacuumizing:
After vacuumizing for 20 min, maintain the container at certain
pressure to ensure that all air in it is exhausted up, and another
inspection shall be made to see whether there is leakage.
6. Take notice when handling with the refrigerant container
(repairing tank):
(a) Do not heat it.
(b) Store the container at the place where temperature is under 40
(c) In case of heating the repairing tank with hot water, care shall
be paid to the valves at the top of tank, do not dip them into the
water, or the water will penetrate into the cooling system.
(d) The empty repairing tank is forbidden to reuse.
8. Take notice when using the high-pressure air cylinder type
inspecting device:
(a) In case the open fire is used, it is the first to ensure before using
there is no flammable material around.
(b) Be careful because toxic gas will be produced when the
gaseous refrigerant meets with the open fire. 7. Take notice in the A/C operation or when adding the liquid
refrigerant:
(a) In case the gaseous refrigerant in the cooling system is
insufficient, which can lead to the compressor burns out, and
such accidents shall be avoided.
(b) If the valve on the side of high pressure is uncovered, the
refrigerant will flow in the reverse direction, which may lead
to the break of the repairing tank, therefore, only valves on the
side of low pressure are allowed to open or closed.
(c) If the repair tank is laid in reverse direction, and the refrigerant
is added in liquid status, the liquid refrigerant will be
compressed, which may lead to failure of the compressor,
therefore, refrigerant shall be inflated in the gaseous status.
(d) Be careful not over-inflate the gaseous refrigerant, otherwise,
such failures as insufficient cooling, increase of oil consuming
or over heat of engine will be followed.
under 40
incorrect
correct
measuring meter of branch pipe
loose over-fastened
A/C operation

Page 367 of 484

AC-4Electric Circuit Diagram of AirConditioning System
Electric circuit diagram of air-conditioning system (continued)
Dr
fuseA/C switch pressure switch
engine wire
harness
air blower
speed-adjusting
module
wind speed switch M2 2
2
2 2
2
2
O 24 4 4 4
4
Q 4
44 3 3
3
3 3 3 3
3
P 5 5
5
5 5 5
5
R 1
1
N 1
1
1
1
N6
6 6
6
6
S 7
7
TU 8
8 9
9 10
10 11 12 13
ignition switch pressure switchA/C switchspeed adjusting
module of air blower
socket connectors of engine wire harnesswind speed switch
lk ^`` p q
fuse ignition switchair-conditioning relayfuse
battery

Page 368 of 484

AC-5Electric Circuit Diagram of AirConditioning System
SF
ST
fusethree-state pressure switch
cold-hot
servomotor circular
servomotor mode
servomotor main air-conditioning
control panel
speed
adjusting
module
air blower
b`r
power resistor
water
valve
Mjjj
M
ACCON
+12V 5
R R 5
5 5 5 5
5
5 PP
P P 3
3
3 3 3 3
3
3
3 1
111
1
1
1 N
N N
1
2 2 2 2
2
22 O O OO
4
44 4
4 4 4Q
Q
Q Q
4
6 6
6 6 6
6S S 6
S6
7
7
7 8
88 9
9
9 10
1010
1111
12
13 14 15 16 17 18 1920
20 21 22 23 2423
ignition switch modular air-door motor cold-hot air-door motor air-in motor
three-stage
pressure switch speed adjusting
modul air conditioning
ignition switchsmall light relay
fusefuse electronic fan
water temperature relay
fuse
compressor relayelectromagnetic
fan relay
compressor clutch
24
Electric circuit diagram of air-conditioning system (continued)
battery
18
5
17
16
3
15
19
14
22
1
13

Page 369 of 484

AC-6Air-Conditioning System(Electric Circuit Diagram)
S
SL SK SJ
fuse
air-conditioning
request relay
connect with ECUfuseECU
^``lkpq
4
5
1
2
45 6
32
36 54
21
1
2 1
32
ignition switch speed adjusting module
air blower A/C SWITCH pressure switch
1 2 3 4
5 6 7 81 2 3
4 5 61 2 3
4 5 6
1
2 1
2 3 1
2
compressor
electromagnetic fan relay compressor relay
pressure switch fuse
fuse
electromagnetic fan
air-conditioning
request relay
A/Cswitch
blower
air-volume switch
speed-adjusting resistance
heat-sensitive resistance blower relay
charging indicating lamp
ignition switch
air-volume switch Electric circuit diagram of air-conditioning system (continued)
battery
ECU

Page:   < prev 1-10 11-20 21-30 31-40 41-50 next >