sensor GREAT WALL SO COOL 2006 Owner's Manual

Page 363 of 484

BE-85
SF
1 fuel level sensor
2 electric fuel pump
3 connected to cab wire harness
1
2
3
Chassis Wire Harness (continued)
Body Electric SystemWire Harness Distribution

Page 382 of 484

AC-19Air-Conditioning SystemRefrigeration Device
inspectionofevaporator
1. Check the radiating ribs of evaporator to see whether there is
block.
If the radiating rib is blocked, clean it with the compressed air.
Notice: do not wash the evaporator with water.
2. Check the joint to see whether there is crack or scrape.
Make reparation as requirement.
Mount the evaporator parts:
(a) Connect the expansion valve to the entrance joint of evaporator
and screw up the nuts.
Remark: Carefulness should be put on the O-ring seal.
(b) Mount the bracket on the suction pipe with thermal sensor;
(c) Connect the liquid pipe to the entrance joint of expansion
valve and screw up nuts.
(d) Mount the lower cluster housing on evaporator.
(e) Mount the upper cluster housing;
(f) Mount the four screws;
(g) Mount the two clipes;
(h) Mount the HP/LP pressure rubber washer; and
(i) Connect the plugging elements;
1. Mount the refrigeration device.
Mount the refrigeration device with three nuts.
2. Connect the plugging elements;
3. Mount the right glove box (SY rear air-conditioner: mount the
interior trim panel at left rear side).
4. Mount the insulation ring on the inlet and outlet joints;
5. Connect the liquid pipe to the outlet joint of refrigeration device;
Tightening moment(see page AC-8)
6. Connect the suction pipe to the outlet joint of refrigeration pipe;
Tightening moment(see page AC-8)
7. Connect the cathode lead to the storage cell.
8. Vacuumize the air-conditioning system:
Vacuumizing time:
Dr SL SK SF SJvacuumize for 20min and maintain the
pressure for 30min
SY: vacuumize for 30min and maintain the pressure for
another 30min.
9. Inflate the refrigerant in the air-conditioning system and
check to see whether there is air leakage;
Refrigerant quantity:
Dr(600-650)g
SL7000g
SK SJ5600g
SF(700-720)g
SY8500g
expansion valveHP pipe LP pipe