relay HONDA CIVIC 1998 6.G Workshop Manual

Page 1949 of 2189

- '99-'00 Models
i-F;;t
L-t'::-i
"d[ft?"l'
UNDER.HOODFUSE/RELAYBOX
UNDER-DASHFUSE/RELAYBOXPHOTO 58
iGi'i'-----'lBEATEA,'/C RE|AY7.5A
".*1.[F*ft"
See PowerDist.ibution,
FUSE 55HEAIERt/toToR
page 10"9.L-*----::--J
BLU
n
$
Se€ PowsrDl8tdbution,pago 1O11.
g€e PowsrDlslribution,pag€ lGg,
ALOWEFmoToRREIAYPHOTO Il1
BIUBLIVYEI
813
OFN/WHT
BLK
2BIK
G402G402
"lSi:lf:::' >-1
-".. i c.u, I--';-lP;!o;i: I---------J
l ,f 3ffJ?il3'o'"o'o*'on
L __ f_---_-_ :::::: - --- r-- -- J
-f-***;
;Iru
I 'rr l-'n BLowER---:-----.l I A lm-o-roC'------------a---E eaoz - I( M rlProraE3PHoro 12s I Y I=----GG-a -
vtEvl 57c440
Se€ Ground
".","i-l'
Ea
JI
6BLOWERMOTORTIIGHRELAYPHO|O 83
UNDER.HOOOFUSE/RELAYBOX
t
!.-
1 HEATER I"-'FI POWERt Battory lgnition Blower I CONTROL I | | rAlHStStOni (brckup) input molor i pAHel I I I pHoro 13e
I ,,o*", _ ffJtt' t PHoro tr7 | tt I
i motor Power ' 'Jback I wr'vzo
I ;_ |! high relay transislor
Ls::s1gl-tt:---J lJ J I
A6
alK
See GroundOistribution,page '14-5.
za
60-1

Page 1950 of 2189

Air Delivery
- '96-'98 Models
SgE PorvstDistrtbLditr,pags I S9.
9 Y C420
BLx,yEL ELK/'(EL I PHora363
I t FUSE 17 I: H€AITN :
! f I9"",' see Powsr !i f otsaibution, i
LJ----':g':'--.i
UNOER-DASHFUSEiRELAYBOXPHOTA 58
a
er.x,ter- [
".*.. ";:.it#?.9.,,
See Dash andConsole Ughts
RECIRCULATIONCONTROLMOTORPHO|O A2
€\
r
I
I
I
I
S6€ IVCComprsssof Controls
a
c723PHOTO 138vtEw 57GBN/IVHT
12
GBN/NED
13
61
\'a

Page 1952 of 2189

Air Delivery
- '99-'00 Models
a
r--T----.I UNDER-HOOD UNDEB-DASH
| ,ry:i.l? IFUSE/RELAY I t::u:E^tt l:usE/RELAyi
- -{-;;; -
I PJ,'.',8.J390 i
-
T;; ;
- - - - -
I H$3,',8
i 1;:t"* ];FPJ", i i m'.u" se€power i "t8L,,
i t i a l'"0 r3l",lli"i:" aL--{..-----J L-J..----5::---:-J
"",":"rfi?ll, '[r;T:1"
-",*"1-J
*-*..l
,n", ".u I lt I
lr !I See Power I See Power Distnbution.I Distribution, U page 1o-9.
,, L::':l------- *Y=l
"*o "."",,t
[
*,:.'.Y%
Irel-
lt
:'l-4riffi
MODECONTROLMOTOR
;L:L{;I{,tt't{ {f
SensorGround grgund
venl
Air mix5Y poientia,reTgrano9 rnrrul
gIouno
RecircSwilcfi switchcommon mput
Recirc S$,itchtED LEDcontrol common
RECIRCULATIONCONTROLMOTORPHOTO 139
CONTROLPANEL
vtEw 76
So€ Roar II Windolv :
a
Htr Ttr =tr ;l *tr :tr *,tr THtr Ttr =tr ;l *tr :tr *tr Ttr
'il
Ti
Battery lgnition Mod€ Mode Mode L4ode Mode l od€(back up) input detrost h€av heat heav vent motorR€circulato Fresh
IJ
Delogger
L------- ---J
HEATERPUSHswtTcHEs
delrost
Air Airmix mixcool hot;;-; J'J - - - J-JL i- 5:- - -
SLK
812
AFN
13
BFN
See GroundDistribution,page 14-5.
c4 t, cl
WHT I ONN
ft++il
c723
F ash/RoclreSwftch
Reclrc.oat LEo
IY
tt
L__l--tGo3,
See RearWindowOetogger
AIR MIXTURECONTROLMOTOR
(
c9 Y cl1
61-2

Page 1954 of 2189

A/C Compressor Controls
- AllModels
cc5)M7
BLU/RED
?
\a
@
&cCOMPRESSORCLUTCHRELAYPHOfO 10
a
! ,acc, : POWERTRATN! arn.^-^,o..^, I or ENGINE
! ii i"i-iiii"v i.,ii.r | fi 3$18.
I A/C request ! (pCM or ECM)I (ACSJ a pHOrO a6L------J vtEw 70
REO
BEO
1
RED
BLU/FEO
2
BLU/FEO
ct31
:"1'!i'------;
Fi:rz, a ='e6-'s8: A|| moders except D1685vtEw 21 '99100: D16Y5 with l\illT'* = 96-'98: All models
ir'iio ," 99. 00: Dt6y5 wth t\4/t Dl6Bb
atcPRESSUREswtTcH
c752
c1
".,n""t 1(
".r-".rf, "tA% "
"."-:,fi tfr,]4.
v
To facing page ('96''98 models)or page 62'2 ( 99-'00 models).
-Yl
-t---------Jc353
c2'14
vtEW21
c209
A,/CCOMPRESSORCLUTCH
COMPRESSORTHERMALPROTECTOR
UNDER-HOODFUSE/RELAYBOXf-T-*-'.T'---l H53.',EPA?' i-l-------
i iflH* !F,?r",, i f6F"'.i:.",",
| tsBi":J;"#il ! a T| | oaoe 1o-9. ! I I See PowerL_J1_j:_-_j ! H Distriburion.e Y c42o i I
pase 1o-1.
***
f ifi"l'
^ see power ! |
62
!(on bracket)

Page 1955 of 2189

- '96-'98 Models
From C214 onfacing page.
v
"**il'ifr"e;
S€e FwvofDistrih$on,pags 10'11.
UNDER.HOODFUSE/RELAYBOX
HEATERco TROLPANEL----1 Dimmino
I Clrcult -
L------J
See AitDelivery'l ctte
lrcI
I
I
I
10
HEATERFANswtTcH
INDICATOR
62-1

Page 1956 of 2189

AiC Compressor Gontrols (cont'd)
- '99-'00 Models
From page 62.
v
I*"-ilii.,"r,
ihtli4
BLUAVHT
15
6LUAVHT
UNDER.HOODFUSE/RELAYBOX
Seg Pow6rDistrlbutiofl,pag€ 'l Gl1-c353PHO|O 8
l[,,*
';.!, "'""
,c,/cSwitch switchcommon itput
a,/cTHERMOSTATOlt below3"C (37"F).
THERMISTOR
(
B11A A8A B'IO |'r--:=---I A/C lgnition B€ttery II request input (backup) :
".j:[ru*,,ry "..;X
{;[
vtEW 57
HEATERCONTROLPANEL
l'lCswitch SwitchLgD IEDcodrol cormonGrouod
See AirD€livery,RgarWindowD€foggar
BIK
cl
ORN
c5
GBN
r,/cOt'llndicatof
HEATERPUSHswrTcHEs
t/cSwltch
S€e AirDelivefy,RearWindowDslogg6f
See GroundDist.ibdion,page 1,1-5.
Y
I(
=ffi;
(
.I UNDER.
I HOODi FUSE/I RELAYI Box
IJ
62-2
PHOfO 125

Page 1957 of 2189

- How the Circuit Works
Battery voltage is supplied through tuse 56 to the
A,/C compressor clutch r€lay contacts at all times.
With the ignition switch in ON (ll), vollage is applied
to the coil of the A,/C compressor clutch relay
through fuse 17. When you push the A,/C switch
ON, and the heater fan switch is in position | , 2, 3,
or 4, a "ground" input is provided to the engine
control module (ECM) or powertrain control module
(PCM) through the l'lC thermostat and the l'lC
pressure switch.
The A,/C compressor clutch relay is grounded by the
engine control module (ECM) or powertrain control
module (PCM). When energized, the A'lC
compressor clutch relay allows battery voltage to
turn on the A,/C comDressor clutch.
The A,/C ON indicator light comes on when the A,/C
system is requested.
A,/C Thermostat
The A'lC thermostat is located on the evaoorator
housing. The A,/C thermostat turns off the A,/C
compressor clutch if the temperature at the
evaporator goes below 3'C (37'F). This prevents
condensation from freezing on the evaporator fins
and blocking the air delivery into the passenger
compartment. The blower motor will keep running
when the sensor turns off the comDressor.
A,/C Pressure Switch
The fuC oressure switch is located in the condenser
outlet line where refrigerant is in a high
temperature/high pressure liquid state. The switch
will sense abnormally high or low pressure, and
open the circuit. This removes ground, and the
compressor will stop running.
Thermal Protectot
The thermal protector, located on the A,/C
compressor, opens and turns the compressor off if it
senses high temperature. Once the compressor
cools, the switch will close and the compressor will
begin running again.
Refer to the Service Manual (Section 22,
Air Conditioning) for specific tests or
troubleshooting procedures.
62-3

Page 1958 of 2189

Fans
- AllModels\,1 |
splicedtogetherinstead of inthe junctionconnector onDl6Y5 models
c211PHOTO 11
FANRELAYPrtofo 10
Se€ I'i CCompre€sorCont ols
1
ALKAED
a
c352
f BLKaEou Y 9,;%,.cFN I vIEw 5e
;
"'
T
";::-:.."-!
Y:. ---::Y h!ii'in"," :
I : ""'I 'is.2o) :
I i,o''ur,ff;, l;l:'l?'* i
I r- - -, |JBEI :
I ; I control | ;
I :L--J :I ' PoWERTRAIN ordu. ' ENGINE CONTROL '' MODULE
: (PCMoTECM) :I PHAfO 86I wEw 7allqA ----.ENGINECOOLANTTEMPERATUREswtrcH BLLPHO|O 33 ?
Ses GrolndDiskibution,oaqe 14.
,I
H
:I
i:
"'*
1_l
c7531
BLU/BLK
ALK2
BLK
RADIATORFANMOTORI
BLK
BLK1
ELK
c753
CONDENSERFANMOTOR
a
* czsr
page 14.
II
FJ'Glot
c211
Gro!nd
T
Se€ GroundOstribution,Pago 14.4"t1 - '96.f98: All models'99-'00: 016Y5 with M/I 01685"2 = '99-'00: Allmodels exceptD16Y5 with M/T and 01685
cof{oENs€R
* czor33123lCVIl
63

Page 1959 of 2189

- '96-'98 Models
Fromunder,hood i-T ig;Eili--l UiB!'* il-;;.;l
Fuse/Relay Box onrac,nspaee | 1"1 seepower i$f" I i tS^* !
V L-I----q,ryli"--Jr'i
L8ry-s:d-J
| 9 X ,cgr,g "" wxr eru I vr'w i."
i-ITy::.;--l Liff" il;;
i llH**"", liEF; i ?r*'I H UlSIrlOUIrOn, I ello'O58 Llv----
From Under-hood ; ( HEATEB
V L-L---q'i.'g;-.1-
'
i-r-g-.'I.-
".,*"'l
::::ll6iirf{ffi.",".,i';
" $r*,,,, *iiiFr- "
---
-
--'''lB;,zfz
Jl[1__::.fif-o B:er.#:r
"f r**"
Gll".-11yorror"-:'L
+asero€
:'j'd",.,
IL---rr--
IF-F;I
!r---*l,h
...
[
-1-'
Seo Pow€rDisaibution,page 10n 1.
UNDER.HOODFUSE/RELAYBOX
HEATERCONTROLPANEL
r------,F-
L ----- -J
--- - -J
,----------J
A/C ONINOICATOR
See AkDelivery
Gatetc
a,icSwltch
-:{l-lit't;;
L€:_jftH+z
"*f
,"" n,ouno
___-i*-]
63-1

Page 1961 of 2189

- How the Circuit Works
Radiator Fan
Voltage is provided at all times to the radiator fan
relay (contacts) through fuse 57. With the ignition
swilch in ON (ll), voltage is provided to the coil of
the relay through luse 17.
The radiator tan relay can be grounded through
either the engine coolant temperature switch or the
engine control module (ECM) or powertrain control
module (PCM).
The engine coolant temperature switch grounds
the radiator fan relay (coil) when the engine
coolant temperature exceeds 199'F (83'C). The
switch opens when coolanl temperature
decreases 3'- 8'C.
Condenser Fan
Voltage is provided at all times to the condenser fan
relay (contacts) through fuse 56. With the ignition
switch in ON (ll), voltage is provided to the coil of
the relay through fuse 17. When you push the A'lC
switch and put the heater fan switch in 1, 2,3, o( 4
position, the ly'C thermostat comes on, the
condenser fan relay energizes, and the condenser
fan motor runs.
A,/C Thermostat
The A,/C thermostat is located on the evaporator
housing. The A,/C thermostat tums off the A/C
compressor clutch if the temperature at the
evaporator goes below 3'C (37'F). This prevents
condensation from freezing on the evaporator fins
and blocking the air delivery into the passenger
compartment. lf the temperature goes below 3'C
(37"F) tuming off the Ay'C thermostat, ground will be
removed from the condenser fan relay. This will
deenergize the relay and remove voltage from the
condenser fan motor causing the fan to stop running.
Reter to the Service Manual (Section 23, Eleckical)
for specific tests or troubleshooting procedures.
63-3

Page:   < prev 1-10 ... 261-270 271-280 281-290 291-300 301-310 311-320 321-330 331-340 341-350 ... 410 next >