Start button HYUNDAI IONIQ 5 2022 Owners Manual

Page 21 of 663

Foreword / Starting your Electric vehicle
1-16
1. Connect to the power outlet located
in bottom of the rear seat with the
Vehicle Stop/Start button in the ON
position.
ONE1Q011089
2. Use the smart key to unlock the power
outlet cover.
ONE1Q011090N
3. Check the operation status through
the front indicator of the power outlet.
- Blue: Standby
- Red: No power supply even the
power outlet is connected
- Green: Normal power supply
through the normal connection of
the power outlet.
Information
When the used power is exceeded due to
overload, the use of V2L is stopped and
the “V2L function is stopped due to excess
power“ message appears in the cluster.
Disconnect the electronic product to reset
the V2L and follow as below.
-After removing the outdoor V2L
connector, it can be used again by
reconnecting it.
-When using only indoor V2L with the
vehicle ON, if V2L is terminated due
to overload, it can be used only after
restarting.
Information
[V2L discharging mode will shut off if
the vehicle is off using indoor V2L on
the vehicle state of ON.
[Opening the charging door or
connecting the V2L connector to the
charging inlet, the V2L discharging
mode will shut off. If you want to
use the indoor and outdoor V2L
simultaneously, firstly connect the V2L
connector to the charging inlet and use
the indoor V2L.
CAUTION
[Be well-informed of the manual to
prevent accidents.
[The V2L discharging mode is
blocked automatically in case of
overheating. (When the discharging
mode is blocked, check whether
the V2L connector or power plug
is contaminated, worn, corroded
or broken or the home appliance
capacity is over 16 A. If the
temperature falls to proper level
after it is left unattended, you can
use it again. Use proper home
appliances.)

Page 32 of 663

01
1-27
Scheduled Charging
(if equipped)
[You can set-up a charging
schedule for your vehicle using the
Infotainment system or Blue Link
application.
Refer to the infotainment system
manual or the Blue Link application
for detailed information about setting
scheduled charging.
[Scheduled charging can only be
done when using a AC charger or
the portable charger (ICCB: In-Cable
Control Box).
ONE1Q011039
[When scheduled charging is set
and the AC charger or the portable
charger (ICCB: In-Cable Control
Box) is connected for charging, the
indicator lamp blinks from the first
level to the last for about 3 minutes
to indicate that scheduled charging
is set.
[When scheduled charging is set,
charging is not initiated immediately
when the AC charger or portable
charger (ICCB: In-Cable Control
Box) is connected. When immediate
charging is required, press the
charging door open button in the
smart key for 2 seconds or deactivate
the scheduled charge setting with
the infotainment system or Blue Link
application.
Refer to “AC Charge (Station) or Trickle
Charge” for details about connecting
the AC charger and the portable charger
(ICCB: In-Cable Control Box).
When the Charging Connector Is
Locked
Always
lockLock
while
chargingDo not
lock
Before
chargingOX X
While
chargingOO X
Finished
chargingOX X
[‘Always lock’ mode :
The connector locks when the
charging connector is plugged into
the charging inlet. The connector is
locked until all doors are unlocked by
the driver. This mode can be used to
prevent charging cable theft.
- If the charging connector is
unlocked when all doors are
unlocked, but the charging cable
is not disconnected within 15 sec-
onds, the connector will be auto-
matically locked again.
- If the charging connector is
unlocked when all doors are
unlocked, but all doors are locked
again, immediately, the connector
will be automatically locked again.
[‘Lock while charging’ mode :
The connector locks when charg- ing
starts. The connector unlocks when
charging is complete. This mode can
be used when charging in a public
charging station.
[‘Do not lock’ mode :
The connector unlocks regardless of
the state of charging.
Press the charging connector release
button, disconnect the connector.
Be careful to theft of the charging
cable.
SCHEDULED CHARGING

Page 37 of 663

Foreword / Starting your Electric vehicle
1-32
6. Connect the charging plug to the
electric outlet at a AC charging station
to start charging.
ONE1Q011041
7. Check if the charging connector
indicator light () of the high
voltage battery in the instrument
cluster is turned ON. Charging is not
active when the charging connector
indicator light (
) is OFF.
When the charging connector and
charging plug are not connected
properly, reconnect the charging
cable to charge.
Information
[(YHQWKRXJKFKDUJLQJLVSRVVLEOHZLWK
the Start/Stop button in the ON/START
position, for you safety, start charging
when the Start/Stop button is in the
OFF position and the vehicle shifted to
P (Park). After charging has started,
you can use electrical components such
as the radio by pressing the Start/Stop
button to the ACC or ON position.
[During AC charging, the radio
reception may be bad.
[During charging, the gear cannot be
shifted from P (Park) to any other gear.
ONE1Q011058E
8. After charging has started, the
estimated charging time is displayed
on the instrument cluster for about 1
minute.
If you open the driver seat door while
charging, the estimated charging time
is also displayed on the instrument
cluster for about 1 minute. When
scheduled charging or scheduled
air conditioner/heater is set, the
estimated charging time is displayed
as “--” .
Information
Depending on the condition and durability
of the high voltage battery, charger
specifications, and ambient temperature,
the time required for charging the battery
may vary.

Page 40 of 663

01
1-35
ONE1Q011041
6. Check if the charging connector
indicator light () of the high voltage
battery in the instrument cluster is
turned ON. Charging connector is not
active when the charging connector
indicator light (
) is OFF.
When the charging connector is not
connected properly, reconnect the
charging cable to charge it again.
During cold weather, DC charging
may not be available to prevent high
voltage battery degradation.
Information
To control the temperature of the high
voltage battery while charging or when
the battery temperature is high, the air
conditioner is used to cool down the
battery. It may generate noise or vibration
from operation of the air conditioner
compressor and cooling fan, but it is a
normal condition when charging the high
voltage battery. Also, the air conditioner’s
performance may be degraded due to
operation of the cooling system to charge
the high voltage battery. This is a normal
condition.
Information
(YHQWKRXJKFKDUJLQJLVSRVVLEOHZLWK
the Start/Stop button in the ON/START
position, for you safety, start charging
when the Start/Stop button is in the
OFF position and the vehicle shifted to P
(Park). After charging has started, you
can use electrical components such as the
radio by pressing the Start/Stop button to
the ACC or ON position.
During charging, the gear cannot be
shifted from P (Park) to any other gear.
ONE1Q011059E
7. After charging has started, the
estimated charging time is displayed
on the instrument cluster for about 1
minute.
If you open the driver seat door while
charging, the estimated charging time
is also displayed on the instrument
cluster for about 1 minute.

Page 42 of 663

01
1-37
How to Set the Charge Level of the
Portable Charger
ONE1041060N
1. Check the rated current of the electric
outlet prior to connecting the plug to
the outlet.
2. Connect the plug to a household
electric outlet.
3. Check the display window on the
control box.
ONX4EPHQ011024L
4. Press the button (1) on the front of
the control box for 2 to 8 seconds
to adjust the charge level. (Refer to
charging cable type and example for
setting the charge level.)
5. The charge level on the display
window of the control box changes
every time you press the button (1).
6. When setting the charge level is
complete, start charging according to
the portable charge procedure.

Page 46 of 663

01
1-41
Information
To control the temperature of the high
voltage battery while charging, the air
conditioner is used to cool down the
battery. It may generate noise or vibration
from operation of the air conditioner
compressor and cooling fan, but it is a
normal condition when charging the high
voltage battery. Also, the air conditioner’s
performance may be degraded due to
operation of the cooling system to charge
the high voltage battery. This is a normal
condition.
Information
(YHQWKRXJKFKDUJLQJLVSRVVLEOHZLWK
the Start/Stop button in the ON/START
position, for you safety, start charging
when the Start/Stop button is in the
OFF position and the vehicle shifted to P
(Park). After charging has started, you
can use electrical components such as the
radio by pressing the Start/Stop button to
the START or ON position.
During charging, the gear cannot be
shifted from P (Park) to any other gear.
ONE1Q011058E
10. After charging has started, the
estimated charging time is displayed
on the instrument cluster for about 1
minute.
If you open the driver seat door while
charging, the estimated charging time
is also displayed on the instrument
cluster for about 1 minute. When
scheduled charging or scheduled
air conditioner/heater is set, the
estimated charging time is displayed
as “--” .
Information
Depending on the condition and durability
of the high voltage battery, charger
specifications, and ambient temperature,
the time required for charging the battery
may vary.
Checking Charging Status
When charging the high voltage battery,
the charge level can be checked from
outside the vehicle.
For more details, refer to ‘Charge
Indicator Lamp for Electric Vehicle’ in
this chapter.

Page 49 of 663

Foreword / Starting your Electric vehicle
1-44
Indicator Details
CHARGE
LEVEL
12 A
10 A
8 A
6 A
The charging current changes whenever the
button (1) is pressed for less than 1 sec with the
charger plugged into an electrical outlet but
not the vehicle.* The control box
ONX4EPHQ011024L

Page 51 of 663

Foreword / Starting your Electric vehicle
1-46
ONX4EPHQ011009L
Plugged into vehicle (POWER Green ON,
FAULT Red Blink)
[Diagnostic device failure
[Current leakage
[Abnormal temperature
Contact an authorized HYUNDAI dealer.
ONX4EPHQ011010L
[Leakage current failure (POWER Green
ON, FAULT Red Blink)
[After disconnecting and reconnecting
the power plug, press and release the
button for 2 seconds or longer to clear
the error.
Contact an authorized HYUNDAI dealer.
ONX4EPHQ011011L
Power saving mode
[7-segment display is turned off if there
is no status change for more than 1
minute.

Page 55 of 663

Foreword / Starting your Electric vehicle
1-50
DRIVING ELECTRIC VEHICLE
How to Start the Vehicle
1. Holding the smart key, sit in the
driver’s seat.
2. Fasten the seat belt before starting
the vehicle.
3. Make sure to engage the parking
brake.
4. Turn OFF all electrical devices.
5. Make sure to depress and hold the
brake pedal.
6. While depressing the brake pedal,
shift to P (Park).
7. Depress and hold the brake pedal
while pressing the Start/Stop button.
ONE1Q011047
8. When the “” indicator is ON,
you can drive the vehicle.
When the “
” indicator is OFF,
you cannot drive the vehicle. Start the
vehicle again.
9. Depress and hold the brake pedal and
shift to the desired position.
Information
While the charging cable is connected, the
gear cannot be shift from P (Park) to any
other gear for safety reasons.10. Release the parking brake and slowly
release the brake pedal. Check if the
vehicle slowly moves forward, then
depress the accelerator pedal.
How to Stop the Vehicle
1. Hold down the brake pedal while the
vehicle is parked.
2. While depressing the brake pedal,
shift to P (Park).
3. While depressing the brake pedal,
engage the parking brake.
4. While depressing the brake pedal,
press the Start/Stop button and turn
off the vehicle.
ONE1Q011048
5. Check if the “” indicator is
turned OFF on the instrument cluster.
When the “
” indicator is ON
and the gear is in a position other than
P (Park), the driver can accidently
depress the accelerator pedal, causing
the vehicle to move unexpectedly.

Page 61 of 663

Foreword / Starting your Electric vehicle
1-56
WARNING
ONE1051278N
When the function is activating the
indicator lamp will illuminate and high
voltage electricity will be flowing in the
vehicle. Do not touch the high voltage
electric wire (orange), connector, and
all electric components and devices.
This may cause electric shock and lead
to injuries. Also, do not modify your
vehicle in any way. This may affect your
vehicle performance and lead to an
accident.
Warning and Indicator Lights
(related to electric vehicle)
Ready indicator
This indicator illuminates:
When the vehicle is ready to be driven.
- ON : Normal driving is possible.
- OFF : Normal driving is not possible,
or a problem has occurred.
- Blinking : Emergency driving.
When the ready indicator goes OFF
or blinks, there is a problem with the
system. In this case, have your vehicle
inspected by an authorized HYUNDAI
dealer.
Service Warning Light
This warning light illuminates:
[When the Start/Stop button is in the
ON position.
- It illuminates for approximately 3
seconds and then goes off.
[When there is a problem with related
parts of the electric vehicle control
system, such as sensors, etc.
When the warning light illuminates while
driving, or does not go OFF after starting
the vehicle, have your vehicle inspected
by an authorized HYUNDAI dealer.

Page:   1-10 11-20 21-30 31-40 41-50 ... 120 next >