ground INFINITI FX35 2004 Service Manual
Page 1747 of 4449
EC-406
[VQ35DE]
DTC P1065 ECM POWER SUPPLY
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureABS006T1
1. CHECK ECM POWER SUPPLY
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check voltage between ECM terminal 121 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M41, E211
20A fuse
IPDM E/R harness connector E8
Harness for open or short between ECM and IPDM E/R
>> Repair open circuit or short to ground in harness or connectors.
3. CHECK INTERMITTENT INCIDENT
Refer to EC-135, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness or connectors.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
121 R/WPower supply for ECM
(Back-up)[Ignition switch OFF]BATTERY VOLTAGE
(11 - 14V)
Voltage: Battery voltage
MBIB0026E
Page 1751 of 4449
EC-410
[VQ35DE]
DTC P1111, P1136 IVT CONTROL SOLENOID VALVE
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
11 B RIntake valve timing control
solenoid valve (bank 1)[Engine is running]
Warm-up condition
Idle speedBATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Warm-up condition
When revving engine up to 2,500 rpm
quickly7 - 12V
PBIB1790E
Page 1753 of 4449
EC-412
[VQ35DE]
DTC P1111, P1136 IVT CONTROL SOLENOID VALVE
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnostic ProcedureABS006T7
1. CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect intake valve timing control solenoid valve harness connector.
3. Turn ignition switch ON.
4. Check voltage between intake valve timing control solenoid
valve terminal 2 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
10 ORIntake valve timing control
solenoid valve (bank 2)[Engine is running]
Warm-up condition
Idle speedBATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Warm-up condition
When revving engine up to 2,500 rpm
quickly7 - 12V
PBIB1790E
Voltage: Battery voltage
PBIB1562E
PBIB0192E
Page 1754 of 4449
DTC P1111, P1136 IVT CONTROL SOLENOID VALVE
EC-413
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
2. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E19, F49
Harness connectors F10, F211
IPDM E/R harness connector E7
Harness for open or short between intake valve timing control solenoid valve and IPDM E/R
>> Repair harness or connectors.
3. CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR
OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 11 (bank 1) or 10 (bank 2) and intake valve timing con-
trol solenoid valve terminal 1. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F211, F10
Harness for open and short between ECM and intake valve timing control solenoid valve
>> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE
Refer to EC-414, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace intake valve timing control solenoid valve.
6. CHECK INTERMITTENT INCIDENT
Refer to EC-135, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
For wiring diagram, refer to EC-303
for CKP sensor (POS), EC-309 and EC-311 for CMP sensor (PHASE).
>>INSPECTION END Continuity should exist.
Page 1755 of 4449
EC-414
[VQ35DE]
DTC P1111, P1136 IVT CONTROL SOLENOID VALVE
Revision: 2004 November 2004 FX35/FX45
Component InspectionABS006T8
INTAKE VALVE TIMING CONTROL SOLENOID VALVE
1. Disconnect intake valve timing control solenoid valve harness connector.
2. Check resistance between intake valve timing control solenoid
valve terminals as follows.
Removal and InstallationABS006T9
INTAKE VALVE TIMING CONTROL SOLENOID VALVE
Refer to EM-63, "TIMING CHAIN" .
Terminals Resistance
1 and 2 7.0 - 7.5Ω at 20°C (68°F)
1 or 2 and ground∞Ω
(Continuity should not exist)
PBIB0193E
Page 1760 of 4449
DTC P1122 ELECTRIC THROTTLE CONTROL FUNCTION
EC-419
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureABS00CHM
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF
2. Loosen and retighten ground three screws on the body. Refer to EC-141, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
3RThrottle control motor relay
power supply[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
4L/WThrottle control motor
(Close)[Ignition switch: ON]
Engine stopped
Shift lever: D
Accelerator pedal: Released0 - 14V
5L/BThrottle control motor
(Open)[Ignition switch: ON]
Engine stopped
Shift lever: D
Accelerator pedal: Fully depressed0 - 14V
104 L/OR Throttle control motor relay[Ignition switch: OFF]BATTERY VOLTAGE
(11 - 14V)
[Ignition switch: ON]0 - 1.0V
PBIB1104E
PBIB1105E
PBIB2195E
Page 1761 of 4449
EC-420
[VQ35DE]
DTC P1122 ELECTRIC THROTTLE CONTROL FUNCTION
Revision: 2004 November 2004 FX35/FX45
2. CHECK THROTTLE CONTROL MOTOR RELAY INPUT SIGNAL CIRCUIT-I
1. Check voltage between ECM terminal 3 and ground under the
following conditions with CONSULT-II or tester.
OK or NG
OK >> GO TO 10.
NG >> GO TO 3.
3. CHECK THROTTLE CONTROL MOTOR RELAY INPUT SIGNAL CIRCUIT-II
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Disconnect IPDM E/R harness connector E8.
4. Check continuity between ECM terminal 3 and IPDM E/R terminal 42.
Refer to Wiring Diagram.
5. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E19, F49
Harness for open or short between ECM and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK THROTTLE CONTROL MOTOR RELAY POWER SUPPLY CIRCUIT-I
1. Reconnect all harness connectors disconnected.
2. Turn ignition switch OFF.
3. Check voltage between ECM terminal 104 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 9.
NG >> GO TO 6.
Ignition switch Voltage
OFF Approximately 0V
ONBattery voltage
(11 - 14V)
MBIB0028E
Continuity should exist.
Voltage: Battery voltage
PBIB1171E
Page 1762 of 4449
DTC P1122 ELECTRIC THROTTLE CONTROL FUNCTION
EC-421
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
6. CHECK THROTTLE CONTROL MOTOR RELAY POWER SUPPLY CIRCUIT-II
1. Disconnect ECM harness connector.
2. Disconnect IPDM E/R harness connector E9.
3. Check continuity between ECM terminal 104 and IPDM E/R terminal 47.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 8.
NG >> GO TO 7.
7. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness for open or short between ECM and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
8. CHECK FUSE
1. Disconnect 15A fuse.
2. Check 15A fuse for blown.
OK or NG
OK >> GO TO 9.
NG >> Replace 15A fuse.
9. CHECK INTERMITTENT INCIDENT
Refer to EC-135, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
OK or NG
OK >> Replace IPDM E/R. Refer to PG-18, "IPDM E/R (INTELLIGENT POWER DISTRIBUTION MOD-
ULE ENGINE ROOM)" .
NG >> Repair or replace harness or connectors.
10. CHECK THROTTLE CONTROL MOTOR OUTPUT SIGNAL CIRCUIT FOR OPEN OR SHORT
1. Turn ignition switch OFF.
2. Disconnect electric throttle control actuator harness connector.
3. Disconnect ECM harness connector.
4. Check harness continuity between the following terminals.
Refer to Wiring Diagram.
5. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 11.
NG >> Repair or replace.Continuity should exist.
Electric throttle control
actuator terminalECM terminal Continuity
35 Should not exist
4 Should exist
65 Should exist
4 Should not exist
PBIB1557E
Page 1767 of 4449
EC-426
[VQ35DE]
DTC P1124, P1126 THROTTLE CONTROL MOTOR RELAY
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureABS006TQ
1. CHECK THROTTLE CONTROL MOTOR RELAY POWER SUPPLY CIRCUIT-I
1. Turn ignition switch OFF.
2. Check voltage between ECM terminal 104 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 2.
2. CHECK THROTTLE CONTROL MOTOR RELAY POWER SUPPLY CIRCUIT-II
1. Disconnect ECM harness connector.
2. Disconnect IPDM E/R harness connector E9.
3. Check continuity between ECM terminal 104 and IPDM E/R terminal 47.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
3. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness for open or short between ECM and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
3RThrottle control motor relay
power supply[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
104 L/OR Throttle control motor relay[Ignition switch: OFF]BATTERY VOLTAGE
(11 - 14V)
[Ignition switch: ON]0 - 1.0V
Voltage: Battery voltage
PBIB1171E
Continuity should exist.
Page 1768 of 4449
DTC P1124, P1126 THROTTLE CONTROL MOTOR RELAY
EC-427
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
4. CHECK FUSE
1. Disconnect 15A fuse.
2. Check 15A fuse for blown.
OK or NG
OK >> GO TO 8.
NG >> Replace 15A fuse.
5. CHECK THROTTLE CONTROL MOTOR RELAY INPUT SIGNAL CIRCUIT-I
1. Check voltage between ECM terminal 3 and ground under the
following conditions with CONSULT-II or tester.
OK or NG
OK >> GO TO 8.
NG >> GO TO 6.
6. CHECK THROTTLE CONTROL MOTOR RELAY INPUT SIGNAL CIRCUIT-II
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Disconnect IPDM E/R harness connector E8.
4. Check continuity between ECM terminal 3 and IPDM E/R terminal 42.
Refer to Wiring Diagram.
5. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 8.
NG >> GO TO 7.
7. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E19, F49
Harness for open or short between ECM and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
8. CHECK INTERMITTENT INCIDENT
Refer to EC-135, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
OK or NG
OK >> Replace IPDM E/R. Refer to PG-18, "IPDM E/R (INTELLIGENT POWER DISTRIBUTION MOD-
ULE ENGINE ROOM)" .
NG >> Repair or replace harness or connectors.
Ignition switch Voltage
OFF Approximately 0V
ONBattery voltage
(11 - 14V)
MBIB0028E
Continuity should exist.