LUBRICANTPFP:KLG00
Maintenance of Lubricant Quantity in CompressorAJS00149
The lubricant in the compressor circulates through the system with the refrigerant. Add lubricant to compres-
sor when replacing any component or after a large refrigerant leakage occurred. It is important to maintain the
specified amount.
If lubricant quantity is not maintained properly, the following malfunctions may result:
Lack of lubricant: May lead to a seized compressor.
Excessive lubricant: Inadequate cooling (thermal exchange interference)
LUBRICANT
LUBRICANT RETURN OPERATION
Adjust the lubricant quantity according to the test group shown below.
1. CHECK LUBRICANT RETURN OPERATION
Can lubricant return operation be performed?
A/C system works properly.
There is no evidence of a large amount of lubricant leakage.
CAUTION:
If excessive lubricant leakage is noted, never perform the lubricant return operation.
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
2. PERFORM LUBRICANT RETURN OPERATION, PROCEEDING AS FOLLOWS
1. Start engine, and set the following conditions:
–Engine speed: Idling to 1,200 rpm
–A/C switch: ON
–Blower speed: Max. position
–Temp. control: Optional [Set so that intake air temperature is 25 to 30 °C (77 to 86 °F).]
–Intake position: Recirculation (REC)
2. Perform lubricant return operation for about 10 minutes.
3. Stop engine.
>> GO TO 3.
3. CHECK REPLACEMENT PART
Should the compressor be replaced?
YES >> GO TO AT C - 2 9 , "LUBRICANT ADJUSTING PROCEDURE FOR COMPRESSOR REPLACE-
MENT" .
NO >> GO TO AT C - 2 8 , "
LUBRICANT ADJUSTING PROCEDURE FOR COMPONENTS REPLACE-
MENT EXCEPT COMPRESSOR" .
Name : NISSAN A/C System Oil Type S
Part number : KLH00-PAGS0
Page 467 of 4731
ATC-30
AIR CONDITIONER CONTROL
Revision: 2005 July 2005 FX
AIR CONDITIONER CONTROLPFP:27500
Description of Air Conditioner LAN Control SystemAJS0014A
The LAN (Local Area Network) system consists of unified meter and A/C amp., mode door motor, air mix door
motor and intake door motor.
A configuration of these components is shown in the diagram below.
System ConstructionAJS0014B
A small network is constructed between the unified meter and A/C amp., air mix door motor, mode door motor
and intake door motor. The unified meter and A/C amp. and motors are connected by data transmission lines
and motor power supply lines. The LAN network is built through the ground circuits of each door motor.
Addresses, motor opening angle signals, motor stop signals and error checking messages are all transmitted
through the data transmission lines connecting the unified meter and A/C amp. and each door motor.
The following functions are contained in LCUs built into the air mix door motor, the mode door motor and the
intake door motor.
Address
Motor opening angle signals
Data transmission
Motor stop and drive decision
Opening angle sensor (PBR function)
Comparison
Decision (Unified meter and A/C amp. indicated value and motor opening angle comparison)
OPERATION
The unified meter and A/C amp. receives data from each of the sensors. The unified meter and A/C amp.
sends mode door, air mix door and intake door opening angle data to the mode door motor LCU, air mix door
motor LCU and intake door motor LCU.
The mode door motor, air mix door motor and intake door motor read their respective signals according to the
address signal. Opening angle indication signals received from the unified meter and A/C amp. and each of
the motor position sensors is compared by the LCUs in each motor with the existing decision and opening
angles. Subsequently, HOT/COLD, DEF/VENT and FRESH/RECIRCULATION operation is selected. The new
selection data is returned to the unified meter and A/C amp.
SJIA0262E
RJIA1747E
Page 468 of 4731
AIR CONDITIONER CONTROL ATC-31
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2005 July 2005 FX
TRANSMISSION DATA AND TRANSMISSION ORDER
Unified meter and A/C amp. data is transmitted consecutively to each of the door motors following the form
shown in figure below.
Start:
Initial compulsory signal sent to each of the door motors.
Address:
Data sent from the unified meter and A/C amp. are selected according to data-based decisions made by the
air mix door motor, mode door motor and intake door motor.
If the addresses are identical, the opening angle data and error check signals are received by the door motor
LCUs. The LCUs then make the appropriate error decision. If the opening angle data have no error, door con-
trol begins.
If an error exists, the received data are rejected and corrected data received. Finally, door control is based
upon the corrected opening angle data.
Opening Angle:
Data that shows the indicated door opening angle of each door motor.
Error Check:
Procedure by which sent and received data is checked for errors. Error data are then compiled. The error
check prevents corrupted data from being used by the air mix door motor, the mode door motor and the intake
door motor. Error data can be related to the following symptoms.
Malfunction of electrical frequency
Poor electrical connections
Signal leakage from transmission lines
Signal level fluctuation
RJIA1748E
Page 469 of 4731
ATC-32
AIR CONDITIONER CONTROL
Revision: 2005 July 2005 FX
Stop Signal:
At the end of each transmission, a stop operation, in-operation, or internal malfunction message is delivered to
the unified meter and A/C amp. This completes one data transmission and control cycle.
AIR MIX DOOR CONTROL (AUTOMATIC TEMPERATURE CONTROL)
The air mix door is automatically controlled so that in-vehicle temperature is maintained at a predetermined
value by the temperature setting, ambient temperature, in-vehicle temperature and amount of sunload.
FAN SPEED CONTROL
Blower speed is automatically controlled by the temperature setting, ambient temperature, in-vehicle tempera-
ture, intake temperature, amount of sunload and air mix door position.
With pressing AUTO switch, the blower motor starts to gradually increase air flow volume.
When engine coolant temperature is low, the blower motor operation is delayed to prevent cool air from flow-
ing.
INTAKE DOOR CONTROL
The intake doors are automatically controlled by the temperature setting, ambient temperature, in-vehicle tem-
perature, intake temperature, amount of sunload and ON-OFF operation of the compressor.
OUTLET DOOR CONTROL
The outlet door is automatically controlled by the temperature setting, ambient temperature, in-vehicle temper-
ature, intake temperature and amount of sunload.
RJIA1749E
Page 470 of 4731
AIR CONDITIONER CONTROL ATC-33
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2005 July 2005 FX
MAGNET CLUTCH CONTROL
When A/C switch or DEF switch is pressed, unified meter and A/C amp. inputs compressor ON signal to BCM.
BCM sends compressor ON signal to ECM, via CAN communication line.
ECM judges whether compressor can be turned ON, based on each sensor status (refrigerant-pressure sen-
sor signal, throttle angle, etc.). If it judges compressor can be turned ON, it sends compressor ON signal to
IPDM E/R, via CAN communication line.
Upon receipt of compressor ON signal from ECM, IPDM E/R turns air conditioner relay ON to operate com-
pressor.
When sending compressor ON signal to IPDM E/R via CAN communication line, ECM simultaneously sends
compressor feedback signal to unified meter and A/C amp. via CAN communication line.
Unified meter and A/C amp., then, uses input compressor feedback signal to control air inlet.
SELF-DIAGNOSIS SYSTEM
The self-diagnosis system is built into the unified meter and A/C amp. to quickly locate the cause of symp-
toms.
RJIA1957E
Page 471 of 4731
ATC-34
AIR CONDITIONER CONTROL
Revision: 2005 July 2005 FX
Description of Control SystemAJS0014C
The control system consists of input sensors, switches, the unified meter and A/C amp. (microcomputer) and
outputs. The relationship of these components is shown in the figure below:
Control OperationAJS0014D
DISPLAY SCREEN
Displays the operational status of the system.
RJIA1958E
RJIA1959E
Page 472 of 4731
AIR CONDITIONER CONTROL ATC-35
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2005 July 2005 FX
AUTO SWITCH
The compressor, intake doors, air mix doors, mode doors and blower speed are automatically controlled
so that the in-vehicle temperature will reach, and be maintained at the set temperature selected by the
operator.
When pressing AUTO switch, air inlet, air outlet, fan speed, and discharge air temperature are automati-
cally controlled.
TEMPERATURE SWITCH (POTENTIO TEMPERATURE CONTROL) (DRIVER SIDE)
The set temperature is increased or decreased with this dial.
TEMPERATURE SWITCH (POTENTIO TEMPERATURE CONTROL) (PASSENGER SIDE)
The set temperature is increased or decreased with this dial.
When the temperature switch is pressed, the dual switch indicator will automatically illuminate.
RECIRCULATION (REC) SWITCH
When REC switch is ON, REC switch indicator turns ON, and air inlet is fixed to REC.
When REC switch is ON and is pressed for approximately 1.5 seconds or longer, REC and FRE switch
indicators blink twice. Then, automatic control mode is entered. Inlet status is displayed even during auto-
matically controlled.
When FRE switch is turned ON, or when compressor is turned from ON to OFF, REC switch is automati-
cally turned OFF (fixed to FRE mode). REC mode can be re-entered by pressing REC switch again.
REC switch is not operated when DEF switch is turned ON, or at the D/F position.
FRESH (FRE) SWITCH
When FRE switch is ON, FRE switch indicator turns ON, and air inlet is fixed to FRE.
When FRE switch is ON and is pressed for approximately 1.5 seconds or longer, REC and FRE switch
indicators blink twice. Then, automatic control mode is entered. Inlet status is displayed even during auto-
matically controlled.
When REC switch is turned ON, FRE switch is automatically turned OFF (fixed to REC mode). FRE mode
can be re-entered by pressing FRE switch again.
DEFROSTER (DEF) SWITCH
Mode doors are set to the defrost position with this switch. Also, intake doors are set to the outside air position,
and compressor turns ON.
REAR WINDOW DEFOGGER SWITCH
When illumination is ON, rear window is defogged.
OFF SWITCH
Compressor and blower are OFF, the intake doors are set to the outside air position, and the mode doors are
set to the foot (75% foot and 25% defrost) position.
A/C SWITCH
Compressor is ON or OFF.
(Pressing the A/C switch when the AUTO switch is ON will turn off the A/C switch and compressor.)
MODE SWITCH
The air discharge outlets is controlled by this switch.
FAN SWITCH
The blower speed is manually controlled with this switch. Seven speeds are available for manual control (as
shown on the display screen).
DUAL SWITCH (WITH LEFT AND RIGHT VENTILATION TEMPERATURE SEPARATELY CON-
TROL SYSTEM)
When the DUAL switch indicator is illuminated, the driver-side outlet and passenger-side outlet, as well as
the setting temperature, can each be set independently.
When the DUAL switch indicator is not illuminated, the driver-side outlet and setting temperature is
applied to both sides.
Page 473 of 4731
ATC-36
AIR CONDITIONER CONTROL
Revision: 2005 July 2005 FX
Fail-safe FunctionAJS0014E
If a communication error exists between unified meter and A/C amp. and A/C and AV switch for 30 sec-
onds or longer, air conditioner is controlled under following conditions:
–Compressor: ON
–Air outlet: AUTO
–Air inlet: FRE (Fresh)
–Blower fan speed: AUTO
–Set temperature: Setting before communication error occurs
Page 474 of 4731
AIR CONDITIONER CONTROL ATC-37
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2005 July 2005 FX
Discharge Air FlowAJS0014F
RJIA1960E
Page 475 of 4731
ATC-38
AIR CONDITIONER CONTROL
Revision: 2005 July 2005 FX
System DescriptionAJS0014G
SWITCHES AND THEIR CONTROL FUNCTION
RJIA1961E
RJIA1962E