air INFINITI FX35 2005 Service Manual
Page 2724 of 4731
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS) EC-1331
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)PFP:14956
DescriptionABS007WK
SYSTEM DESCRIPTION
*: The ECM determines the start signal status by the signals of engine speed and battery voltage.
When the engine is running at low or medium speed, the power valve is fully closed. Under this condition, the
effective suction port length is equivalent to the total length of the intake manifold collector's suction port
including the intake valve. This long suction port provides increased air intake which results in improved suc-
tion efficiency and higher torque generation.
The surge tank and one-way valve are provided. When engine is running at high speed, the ECM sends the
signal to the VIAS control solenoid valve. This signal introduces the intake manifold vacuum into the power
valve actuator and therefore opens the power valve to two suction passages together in the collector.
Under this condition, the effective port length is equivalent to the length of the suction port provided indepen-
dently for each cylinder. This shortened port length results in enhanced engine output with reduced suction
resistance under high speeds.
The power valve is always open regardless of the engine speed when gear position is in N or P.
Sensor Input signal to ECM ECM function Actuator
Crankshaft position sensor (POS)
Camshaft position sensor (PHASE) Engine speed*
VIAS control VIAS control solenoid valve
Mass air flow sensor Amount of intake air
Throttle position sensor Throttle position
Accelerator pedal position sensor Accelerator pedal position
Battery Battery voltage*
Engine coolant temperature sensor Engine coolant temperature
PBIB1876E
Page 2725 of 4731
EC-1332
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2005 July 2005 FX
COMPONENT DESCRIPTION
Power Valve
The power valve is installed in intake manifold collector and used to
control the suction passage of the variable induction air control sys-
tem. It is set in the fully closed or fully opened position by the power
valve actuator operated by the vacuum stored in the surge tank. The
vacuum in the surge tank is controlled by the VIAS control solenoid
valve.
VIAS Control Solenoid Valve
The VIAS control solenoid valve cuts the intake manifold vacuum
signal for power valve control. It responds to ON/OFF signals from
the ECM. When the solenoid is off, the vacuum signal from the
intake manifold is cut. When the ECM sends an ON signal the coil
pulls the plunger downward and feeds the vacuum signal to the
power valve actuator.
CONSULT-II Reference Value in Data Monitor ModeABS007WL
PBIB1498E
PBIB1498E
MONITOR ITEM CONDITION SPECIFICATION
VIAS S/V
Engine speed: Idle Selector lever: P or N
and/or
Engine speed: More than 5,000 rpm ON
Except above OFF
Page 2726 of 4731
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS) EC-1333
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Wiring DiagramABS007WM
TBWM0849E
Page 2727 of 4731
EC-1334
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureABS007WN
1. CHECK OVERALL FUNCTION
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Perform “VIAS SOL VALVE” in “ACTIVE TEST” mode with CONSULT-II.
3. Turn VIAS control solenoid valve ON and OFF, and make sure that power valve actuator rod moves.
Without CONSULT-II
1. Lift up the vehicle.
2. Start engine and warm it up to normal operating temperature.
3. Make sure that power valve actuator rod moves when changing the gear position to N and D alternately.
OK or NG
OK >> INSPECTION END
NG (With CONSULT-II)>>GO TO 2.
NG (Without CONSULT-II)>>GO TO 3.
TER-
MINAL NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
29 GY VIAS control solenoid valve [Engine is running]
Selector lever: P or N
0 - 1.0V
[Engine is running]
Selector lever: D BATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Engine speed: Above 5,000 rpm 0 - 1.0V
PBIB0171E
PBIB0172E
Page 2728 of 4731
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS) EC-1335
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
2. CHECK VACUUM EXISTENCE
With CONSULT-II
1. Stop engine and disconnect vacuum hose connected to power valve actuator.
2. Start engine and let it idle.
3. Perform “VIAS SOL VALVE” in “ACTIVE TEST” mode with CONSULT-II.
4. Turn VIAS control solenoid valve ON and OFF, and check vacuum existence under the following condi- tions.
OK or NG
OK >> Repair or replace power valve actuator.
NG >> GO TO 4.
3. CHECK VACUUM EXISTENCE
Without CONSULT-II
1. Stop engine and disconnect vacuum hose connected to power valve actuator.
2. Disconnect VIAS control solenoid valve harness connector.
3. Start engine and let it idle.
4. Apply 12V of direct current between VIAS control solenoid valve terminals 1 and 2.
5. Check vacuum existence under the following conditions.
OK or NG
OK >> Repair or replace power valve actuator.
NG >> GO TO 4.
VIAS SOL VALVE Vacuum
ON Should exist.
OFF Should not exist.
PBIB0174E
Condition Vacuum
12V direct current supply Should exist.
No supply Should not exist.
PBIB0175E
Page 2729 of 4731
EC-1336
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2005 July 2005 FX
4. CHECK VACUUM HOSE
1. Stop engine.
2. Check hoses and tubes between intake manifold and power valve actuator for crack, clogging, improper connection or dis-
connection. Refer to EC-810, "
Vacuum Hose Drawing" .
OK or NG
OK >> GO TO 5.
NG >> Repair hoses or tubes.
5. CHECK VACUUM TANK
Refer to EC-1337, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace vacuum tank.
6. CHECK VIAS CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect VIAS control solenoid valve harness connector.
3. Turn ignition switch ON.
4. Check voltage between terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 8.
NG >> GO TO 7.
SEF109L
PBIB1498E
Voltage: Battery voltage
PBIB0173E
Page 2730 of 4731
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS) EC-1337
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
7. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness connectors M82, F102
IPDM E/R connector E7
10A fuse
Harness continuity between IPDM E/R and VIAS control solenoid valve
>> Repair open circuit or short to ground or short to power in harness or connectors.
8. CHECK VIAS CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 29 and VIAS control solenoid valve terminal 2. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 9.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
9. CHECK VIAS CONTROL SOLENOID VALVE
Refer to EC-1337, "
Component Inspection" .
OK or NG
OK >> GO TO 10.
NG >> Replace VIAS control solenoid valve.
10. CHECK INTERMITTENT INCIDENT
Refer to EC-854, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>> INSPECTION END
Component InspectionABS007WO
VIAS CONTROL SOLENOID VALVE
With CONSULT-II
1. Reconnect harness connectors disconnected.
2. Turn ignition switch ON.
3. Perform “VIAS SOL VALVE” in “ACTIVE TEST” mode.
4. Check air passage continuity and operation delay time under the following conditions.
Operation takes less than 1 second. Continuity should exist.
Condition
VIAS SOL VALVE Air passage continuity
between A and B Air passage continuity
between A and C
ON Yes No
OFF No Yes
PBIB0177E
Page 2731 of 4731
EC-1338
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2005 July 2005 FX
Without CONSULT-II
Check air passage continuity and operation delay time under the fol-
lowing conditions.
Operation takes less than 1 second.
VACUUM TANK
1. Disconnect vacuum hose connected to vacuum tank.
2. Connect a vacuum pump to the port A of vacuum tank.
3. Apply vacuum and make sure that vacuum exists at the port B.
Removal and InstallationABS007WP
VIAS CONTROL SOLENOID VALVE
Refer to EM-178, "INTAKE MANIFOLD" .
Condition Air passage continuity
between A and B Air passage continuity
between A and C
12V direct current supply
between terminals 1 and 2 Ye s N o
No supply No Yes
MEC488B
PBIB0846E
Page 2740 of 4731
IGNITION SIGNAL EC-1347
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
5. CHECK IGNITION COIL POWER SUPPLY CIRCUIT-II
1. Turn ignition switch OFF.
2. Disconnect condenser harness connector.
3. Turn ignition switch ON.
4. Check voltage between condenser terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 8.
NG >> GO TO 6.
6. CHECK IGNITION COIL POWER SUPPLY CIRCUIT-III
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R harness connector E7.
3. Check harness continuity between IPDM E/R terminal 17 and condenser terminal 1. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> Go to EC-855, "POWER SUPPLY AND GROUND CIRCUIT" .
NG >> GO TO 7.
7. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E19, F49
Harness for open or short between IPDM E/R and condenser
>> Repair open circuit or short to ground or short to power in harness or connectors.
PBIB1532E
Voltage: Battery voltage
PBIB0624E
Continuity should exist.
Page 2741 of 4731
EC-1348
[VK45DE]
IGNITION SIGNAL
Revision: 2005 July 2005 FX
8. CHECK CONDENSER GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Check harness continuity between condenser terminal 2 and ground. Refer to Wiring Diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 9.
NG >> Repair open circuit or short to power in harness or connectors.
9. CHECK CONDENSER
Refer to EC-1349, "
Component Inspection"
OK or NG
OK >> GO TO 10.
NG >> Replace condenser.
10. CHECK IGNITION COIL POWER SUPPLY CIRCUIT-V
1. Reconnect all harness connectors disconnected.
2. Disconnect ignition coil harness connector.
3. Turn ignition switch ON.
4. Check voltage between ignition coil terminal 3 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 12.
NG >> GO TO 11.
11 . DETECT MALFUNCTIONING PART
Check the following.
Harness connector F49
Harness for open or short between ignition coil and harness connector F49
>> Repair or replace harness or connectors.
Continuity should exist.
Voltage: Battery voltage
PBIB1516E
PBIB0138E