air INFINITI FX35 2005 Service Manual

Page 2742 of 4731

IGNITION SIGNAL EC-1349
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
12. CHECK IGNITION COIL GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Check harness continuity between ignition coil terminal 2 and ground. Refer to Wiring Diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 13.
NG >> Repair open circuit or short to power in harness or connectors.
13. CHECK IGNITION COIL OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminals 46, 60, 61, 62, 65, 79, 80, 81 and ignition coil terminal 1. Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 14.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
14. CHECK IGNITION COIL WITH POWER TRANSISTOR
Refer to EC-1349, "
Component Inspection" .
OK or NG
OK >> GO TO 15.
NG >> Replace ignition coil with power transistor.
15. CHECK INTERMITTENT INCIDENT
Refer to EC-854, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>> INSPECTION END
Component InspectionABS00E5S
IGNITION COIL WITH POWER TRANSISTOR
CAUTION:
Do the following procedure in the place where ventilation is good without the combustible.
1. Turn ignition switch OFF.
2. Disconnect ignition coil harness connector.
3. Check resistance between ignition coil terminals as follows.
4. If NG, replace ignition coil with power transistor. If OK, go to next step.
5. Turn ignition switch OFF.
6. Reconnect all harness connectors disconnected. Continuity should exist.
Continuity should exist.
Terminal No. (Polarity) Resistance
Ω [at 25 °C (77 °F)]
1 and 2 Except 0 or ∞
1 and 3 Except 0
2 and 3
PBIB0847E

Page 2744 of 4731

INJECTOR CIRCUIT EC-1351
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
INJECTOR CIRCUITPFP:16600
Component DescriptionABS007WV
The fuel injector is a small, precise solenoid valve. When the ECM
supplies a ground to the injector circuit, the coil in the injector is
energized. The energized coil pulls the ball valve back and allows
fuel to flow through the injector into the intake manifold. The amount
of fuel injected depends upon the injection pulse duration. Pulse
duration is the length of time the injector remains open. The ECM
controls the injection pulse duration based on engine fuel needs.
CONSULT-II Reference Value in Data Monitor ModeABS007WW
Specification data are reference values.
SEF375Z
MONITOR ITEM CONDITION SPECIFICATION
B/FUEL SCHDL See EC-844, "
TROUBLE DIAGNOSIS - SPECIFICATION VALUE" .
INJ PULSE-B1
INJ PULSE-B2
Engine: After warming up
Selector lever: P or N
Air conditioner switch: OFF
No load Idle 2.0 - 3.0 msec
2,000 rpm 1.9 - 2.9 msec

Page 2748 of 4731

INJECTOR CIRCUIT EC-1355
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M82, F102
Harness connectors F21, F201
Harness connectors F41, F221
Fuse block (J/B) connector M1
15A fuse
Harness for open or short between harness connector F21 and fuse
Harness for open or short between harness connector F41 and fuse
Harness for open or short between harness connector F21 and ECM
Harness for open or short between harness connector F41 and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK FUNCTION OF INJECTOR-II
Provide battery voltage between the following terminals, and then
interrupt it. Listen to each injector operating sound.
OK or NG
OK >> INSPECTION END
NG >> GO TO 6.
Cylinder Harness connector terminal
(+) (–)
1
F201 5 3
32
51
76
2
F221 5 3
42
61
86
Operating sound should exist.
PBIB2449E

Page 2749 of 4731

EC-1356
[VK45DE]
INJECTOR CIRCUIT
Revision: 2005 July 2005 FX
6. CHECK SUB-HARNESS CIRCUIT FOR OPEN AND SHORT
1. Disconnect injector harness connectors.
2. Check harness continuity between the following terminals. Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
7. CHECK INJECTOR
Refer to EC-1357, "
Component Inspection" .
OK or NG
OK >> GO TO 8.
NG >> Replace injector.
8. CHECK INTERMITTENT INCIDENT
Refer to EC-854, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>> INSPECTION END
Harness connector terminal Injector terminal
F201 terminal 1
2
F201 terminal 2
F201 terminal 3
F201 terminal 6
F201 terminal 5 1
F221 terminal 1
2
F221 terminal 2
F221 terminal 3
F221 terminal 6
F221 terminal 5 1
Continuity should exist.
PBIB1518E

Page 2754 of 4731

FUEL PUMP CIRCUIT EC-1361
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
3. CHECK FUEL PUMP POWER SUPPLY CIRCUIT-II
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R harness connector E8.
3. Turn ignition switch ON.
4. Check voltage between IPDM E/R terminal 40 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 4.
NG >> GO TO 11.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness for open or short between IPDM E/R and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK FUEL PUMP POWER SUPPLY CIRCUIT-III
1. Turn ignition switch OFF.
2. Reconnect all harness connectors disconnected.
3. Disconnect “fuel level sensor unit and fuel pump” harness con- nector.
4. Turn ignition switch ON.
5. Check voltage between “fuel level sensor unit and fuel pump” terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 9.
NG >> GO TO 6. Voltage: Battery voltage
PBIB1926E
PBIB1507E
Voltage: Battery voltage should exist for 1 sec-
ond after ignition switch is turned ON.
PBIB0795E

Page 2755 of 4731

EC-1362
[VK45DE]
FUEL PUMP CIRCUIT
Revision: 2005 July 2005 FX
6. CHECK 15A FUSE
1. Turn ignition switch OFF.
2. Disconnect 15A fuse.
3. Check 15A fuse.
OK or NG
OK >> GO TO 7.
NG >> Replace fuse.
7. CHECK FUEL PUMP POWER SUPPLY CIRCUIT-IV
1. Disconnect IPDM E/R harness connector E8.
2. Check harness continuity between IPDM E/R terminal 39 and “fuel level sensor unit and fuel pump” termi- nal 1.
Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 11.
NG >> GO TO 8.
8. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E206, B6
Harness for open or short between IPDM E/R and “fuel level sensor unit and fuel pump”
>> Repair harness or connectors.
9. CHECK FUEL PUMP GROUND CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between “fuel level sensor unit and fuel pump” terminal 3 and ground. Refer to Wiring Diagram.
2. Also check harness for short to power.
OK or NG
OK >> GO TO 10.
NG >> Repair open circuit or short to power in harness or connectors.
10. CHECK FUEL PUMP
Refer to EC-1363, "
Component Inspection" .
OK or NG
OK >> GO TO 11.
NG >> Replace fuel pump.
11 . CHECK INTERMITTENT INCIDENT
Refer to EC-854, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
OK or NG
OK >> Replace IPDM E/R.
NG >> Repair or replace harness or connectors. Continuity should exist.
Continuity should exist.

Page 2757 of 4731

EC-1364
[VK45DE]
REFRIGERANT PRESSURE SENSOR
Revision: 2005 July 2005 FX
REFRIGERANT PRESSURE SENSORPFP:92136
Component DescriptionABS007X7
The refrigerant pressure sensor is installed at the condenser of the
air conditioner system. The sensor uses an electrostatic volume
pressure transducer to convert refrigerant pressure to voltage. The
voltage signal is sent to ECM, and ECM controls cooling fan system.
PBIB1492E
PBIB2657E

Page 2759 of 4731

EC-1366
[VK45DE]
REFRIGERANT PRESSURE SENSOR
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureABS007X9
1. CHECK REFRIGERANT PRESSURE SENSOR OVERALL FUNCTION
1. Start engine and warm it up to normal operating temperature.
2. Turn A/C switch and blower switch ON.
3. Check voltage between ECM terminal 70 and ground with CON- SULT-II or tester.
OK or NG
OK >> INSPECTION END
NG >> GO TO 2.
2. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body. Refer to EC-861, "
Ground Inspection" .
OK or NG
OK >> GO TO 3.
NG >> Repair or replace ground connections.
TER-
MINAL NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
49 PU Sensor power supply
(Refrigerant pressure sen-
sor) [Ignition switch: ON]
Approximately 5V
67 B/W Sensor ground [Engine is running]
Warm-up condition
Idle speed Approximately 0V
70 L/R Refrigerant pressure sensor [Engine is running]
Warm-up condition
Both A/C switch and blower fan motor
switch: ON (Compressor operates) 1.0 - 4.0V
Voltage: 1.0 - 4.0V
PBIB1188E
PBIB2195E

Page 2760 of 4731

REFRIGERANT PRESSURE SENSOR EC-1367
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
3. CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Disconnect refrigerant pressure sensor harness connector.
2. Turn ignition switch ON.
3. Check voltage between refrigerant pressure sensor terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E17, F47
Harness for open or short between ECM and refrigerant pressure sensor
>> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between refrigerant pressure sensor terminal 3 and ECM terminal 67. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E17, F47
Harness for open or short between ECM and refrigerant pressure sensor
>> Repair open circuit or short to ground or short to power in harness or connectors.
PBIB1492E
Voltage: Approximately 5V
PBIB0188E
Continuity should exist.

Page 2761 of 4731

EC-1368
[VK45DE]
REFRIGERANT PRESSURE SENSOR
Revision: 2005 July 2005 FX
7. CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between ECM terminal 70 and refrigerant pressure sensor terminal 2. Refer to Wiring Diagram.
2. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 9.
NG >> GO TO 8.
8. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E17, F47
Harness for open or short between ECM and refrigerant pressure sensor
>> Repair open circuit or short to ground or short to power in harness or connectors.
9. CHECK INTERMITTENT INCIDENT
Refer to EC-854, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
OK or NG
OK >> Replace refrigerant pressure sensor.
NG >> Repair or replace.
Removal and InstallationABS007XA
REFRIGERANT PRESSURE SENSOR
Refer to ATC-156, "Removal and Installation of Refrigerant Pressure Sensor" .
Continuity should exist.

Page:   < prev 1-10 ... 1161-1170 1171-1180 1181-1190 1191-1200 1201-1210 1211-1220 1221-1230 1231-1240 1241-1250 ... 1790 next >