recirculation INFINITI FX35 2005 Service Manual

Page 438 of 4731

ATC-1
AUTOMATIC AIR CONDITIONER
J AIR CONDITIONER
CONTENTS
C
D E
F
G H
I
K L
M
SECTION AT C
A
B
AT C
Revision: 2005 July 2005 FX
AUTOMATIC AIR CONDITIONER
PRECAUTIONS .......................................................... 5
Precautions for Supplemental Restraint System
(SRS) “AIR BAG” and “SEAT BELT PRE-TEN-
SIONER” ............................................................. ..... 5
Precautions Necessary for Steering Wheel Rotation
After Battery Disconnect ..................................... ..... 5
OPERATION PROCEDURE ............................ ..... 5
Precautions for Procedures without Cowl Top Cover ..... 6
Precautions for Working with HFC-134a (R-134a) ..... 6
CONTAMINATED REFRIGERANT .................. ..... 7
General Refrigerant Precautions ......................... ..... 7
Precautions for Refrigerant Connection .............. ..... 8
ABOUT ONE-TOUCH JOINT ........................... ..... 8
FEATURES OF NEW TYPE REFRIGERANT
CONNECTION ................................................. ... 10
O-RING AND REFRIGERANT CONNECTION .... 11
Precautions for Servicing Compressor ................ ... 13
Precautions for Service Equipment ..................... ... 13
RECOVERY/RECYCLING EQUIPMENT ......... ... 13
ELECTRONIC LEAK DETECTOR ................... ... 13
VACUUM PUMP .............................................. ... 14
MANIFOLD GAUGE SET ................................. ... 14
SERVICE HOSES ............................................ ... 14
SERVICE COUPLERS ..................................... ... 15
REFRIGERANT WEIGHT SCALE ................... ... 15
CHARGING CYLINDER ................................... ... 15
Precautions for Leak Detection Dye .................... ... 16
IDENTIFICATION ............................................. ... 16
IDENTIFICATION LABEL FOR VEHICLE ........ ... 16
PREPARATION ...................................................... ... 17
Special Service Tools .......................................... ... 17
HFC-134a (R-134a) Service Tools and Equipment ... 18
Commercial Service Tools ................................... ... 20
REFRIGERATION SYSTEM .................................. ... 21
Refrigerant Cycle ................................................ ... 21
REFRIGERANT FLOW .................................... ... 21
FREEZE PROTECTION .................................. ... 21
Refrigerant System Protection ............................ ... 21
REFRIGERANT PRESSURE SENSOR .......... ... 21
PRESSURE RELIEF VALVE ............................ ... 21 V-6 Variable Displacement Compressor ..............
... 22
GENERAL INFORMATION .............................. ... 22
DESCRIPTION ................................................. ... 23
Component Layout .............................................. ... 26
LUBRICANT ........................................................... ... 27
Maintenance of Lubricant Quantity in Compressor ... 27
LUBRICANT ..................................................... ... 27
LUBRICANT RETURN OPERATION ............... ... 27
LUBRICANT ADJUSTING PROCEDURE FOR
COMPONENTS REPLACEMENT EXCEPT
COMPRESSOR ............................................... ... 28
LUBRICANT ADJUSTING PROCEDURE FOR
COMPRESSOR REPLACEMENT .................... ... 29
AIR CONDITIONER CONTROL ............................ ... 30
Description of Air Conditioner LAN Control System ... 30
System Construction ........................................... ... 30
OPERATION ..................................................... ... 30
TRANSMISSION DATA AND TRANSMISSION
ORDER ............................................................ ... 31
AIR MIX DOOR CONTROL (AUTOMATIC TEM-
PERATURE CONTROL) .................................. ... 32
FAN SPEED CONTROL ................................... ... 32
INTAKE DOOR CONTROL .............................. ... 32
OUTLET DOOR CONTROL ............................. ... 32
MAGNET CLUTCH CONTROL ........................ ... 33
SELF-DIAGNOSIS SYSTEM ........................... ... 33
Description of Control System ............................. ... 34
Control Operation ................................................ ... 34
DISPLAY SCREEN ........................................... ... 34
AUTO SWITCH ................................................ ... 35
TEMPERATURE SWITCH (POTENTIO TEM-
PERATURE CONTROL) (DRIVER SIDE) ........ ... 35
TEMPERATURE SWITCH (POTENTIO TEM-
PERATURE CONTROL) (PASSENGER SIDE) ... 35
RECIRCULATION (REC) SWITCH .................. ... 35
FRESH (FRE) SWITCH ................................... ... 35
DEFROSTER (DEF) SWITCH .......................... ... 35
REAR WINDOW DEFOGGER SWITCH .......... ... 35
OFF SWITCH ................................................... ... 35
A/C SWITCH .................................................... ... 35

Page 464 of 4731

LUBRICANT ATC-27
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2005 July 2005 FX
LUBRICANTPFP:KLG00
Maintenance of Lubricant Quantity in CompressorAJS00149
The lubricant in the compressor circulates through the system with the refrigerant. Add lubricant to compres-
sor when replacing any component or after a large refrigerant leakage occurred. It is important to maintain the
specified amount.
If lubricant quantity is not maintained properly, the following malfunctions may result:
Lack of lubricant: May lead to a seized compressor.
Excessive lubricant: Inadequate cooling (thermal exchange interference)
LUBRICANT
LUBRICANT RETURN OPERATION
Adjust the lubricant quantity according to the test group shown below.
1. CHECK LUBRICANT RETURN OPERATION
Can lubricant return operation be performed?
A/C system works properly.
There is no evidence of a large amount of lubricant leakage.
CAUTION:
If excessive lubricant leakage is noted, never perform the lubricant return operation.
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
2. PERFORM LUBRICANT RETURN OPERATION, PROCEEDING AS FOLLOWS
1. Start engine, and set the following conditions:
–Engine speed: Idling to 1,200 rpm
–A/C switch: ON
–Blower speed: Max. position
–Temp. control: Optional [Set so that intake air temperature is 25 to 30 °C (77 to 86 °F).]
–Intake position: Recirculation (REC)
2. Perform lubricant return operation for about 10 minutes.
3. Stop engine.
>> GO TO 3.
3. CHECK REPLACEMENT PART
Should the compressor be replaced?
YES >> GO TO AT C - 2 9 , "LUBRICANT ADJUSTING PROCEDURE FOR COMPRESSOR REPLACE-
MENT" .
NO >> GO TO AT C - 2 8 , "
LUBRICANT ADJUSTING PROCEDURE FOR COMPONENTS REPLACE-
MENT EXCEPT COMPRESSOR" .
Name : NISSAN A/C System Oil Type S
Part number : KLH00-PAGS0

Page 467 of 4731

ATC-30
AIR CONDITIONER CONTROL
Revision: 2005 July 2005 FX
AIR CONDITIONER CONTROLPFP:27500
Description of Air Conditioner LAN Control SystemAJS0014A
The LAN (Local Area Network) system consists of unified meter and A/C amp., mode door motor, air mix door
motor and intake door motor.
A configuration of these components is shown in the diagram below.
System ConstructionAJS0014B
A small network is constructed between the unified meter and A/C amp., air mix door motor, mode door motor
and intake door motor. The unified meter and A/C amp. and motors are connected by data transmission lines
and motor power supply lines. The LAN network is built through the ground circuits of each door motor.
Addresses, motor opening angle signals, motor stop signals and error checking messages are all transmitted
through the data transmission lines connecting the unified meter and A/C amp. and each door motor.
The following functions are contained in LCUs built into the air mix door motor, the mode door motor and the
intake door motor.
Address
Motor opening angle signals
Data transmission
Motor stop and drive decision
Opening angle sensor (PBR function)
Comparison
Decision (Unified meter and A/C amp. indicated value and motor opening angle comparison)
OPERATION
The unified meter and A/C amp. receives data from each of the sensors. The unified meter and A/C amp.
sends mode door, air mix door and intake door opening angle data to the mode door motor LCU, air mix door
motor LCU and intake door motor LCU.
The mode door motor, air mix door motor and intake door motor read their respective signals according to the
address signal. Opening angle indication signals received from the unified meter and A/C amp. and each of
the motor position sensors is compared by the LCUs in each motor with the existing decision and opening
angles. Subsequently, HOT/COLD, DEF/VENT and FRESH/RECIRCULATION operation is selected. The new
selection data is returned to the unified meter and A/C amp.
SJIA0262E
RJIA1747E

Page 472 of 4731

AIR CONDITIONER CONTROL ATC-35
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2005 July 2005 FX
AUTO SWITCH
The compressor, intake doors, air mix doors, mode doors and blower speed are automatically controlled
so that the in-vehicle temperature will reach, and be maintained at the set temperature selected by the
operator.
When pressing AUTO switch, air inlet, air outlet, fan speed, and discharge air temperature are automati-
cally controlled.
TEMPERATURE SWITCH (POTENTIO TEMPERATURE CONTROL) (DRIVER SIDE)
The set temperature is increased or decreased with this dial.
TEMPERATURE SWITCH (POTENTIO TEMPERATURE CONTROL) (PASSENGER SIDE)
The set temperature is increased or decreased with this dial.
When the temperature switch is pressed, the dual switch indicator will automatically illuminate.
RECIRCULATION (REC) SWITCH
When REC switch is ON, REC switch indicator turns ON, and air inlet is fixed to REC.
When REC switch is ON and is pressed for approximately 1.5 seconds or longer, REC and FRE switch
indicators blink twice. Then, automatic control mode is entered. Inlet status is displayed even during auto-
matically controlled.
When FRE switch is turned ON, or when compressor is turned from ON to OFF, REC switch is automati-
cally turned OFF (fixed to FRE mode). REC mode can be re-entered by pressing REC switch again.
REC switch is not operated when DEF switch is turned ON, or at the D/F position.
FRESH (FRE) SWITCH
When FRE switch is ON, FRE switch indicator turns ON, and air inlet is fixed to FRE.
When FRE switch is ON and is pressed for approximately 1.5 seconds or longer, REC and FRE switch
indicators blink twice. Then, automatic control mode is entered. Inlet status is displayed even during auto-
matically controlled.
When REC switch is turned ON, FRE switch is automatically turned OFF (fixed to REC mode). FRE mode
can be re-entered by pressing FRE switch again.
DEFROSTER (DEF) SWITCH
Mode doors are set to the defrost position with this switch. Also, intake doors are set to the outside air position,
and compressor turns ON.
REAR WINDOW DEFOGGER SWITCH
When illumination is ON, rear window is defogged.
OFF SWITCH
Compressor and blower are OFF, the intake doors are set to the outside air position, and the mode doors are
set to the foot (75% foot and 25% defrost) position.
A/C SWITCH
Compressor is ON or OFF.
(Pressing the A/C switch when the AUTO switch is ON will turn off the A/C switch and compressor.)
MODE SWITCH
The air discharge outlets is controlled by this switch.
FAN SWITCH
The blower speed is manually controlled with this switch. Seven speeds are available for manual control (as
shown on the display screen).
DUAL SWITCH (WITH LEFT AND RIGHT VENTILATION TEMPERATURE SEPARATELY CON-
TROL SYSTEM)
When the DUAL switch indicator is illuminated, the driver-side outlet and passenger-side outlet, as well as
the setting temperature, can each be set independently.
When the DUAL switch indicator is not illuminated, the driver-side outlet and setting temperature is
applied to both sides.

Page 497 of 4731

ATC-60
TROUBLE DIAGNOSIS
Revision: 2005 July 2005 FX
AUXILIARY MECHANISM: FOOT POSITION SETTING TRIMMER
Wind distribution ratio in FOOT mode can be set.
Operating procedures for this trimmer are as follows:
1. Begin self-diagnosis STEP-5 mode. Refer to AT C - 5 3 , "
Self-diagnosis Function" .
2. Press (fan) UP switch to set system in auxiliary mode.
3. Display shows 61 in auxiliary mechanism. It takes approximately 3 seconds.
4. Press the mode switch as desired.
AUXILIARY MECHANISM: INLET PORT MEMORY FUNCTION
When ignition switch is turned from OFF to ON, inlet port can be set to AUTO or manual.
Operating procedures for this trimmer are as follows:
1. Begin self-diagnosis STEP-5 mode. Refer to AT C - 5 3 , "
Self-diagnosis Function" .
2. Press (fan) UP switch to set system in auxiliary mode.
3. Display shows 61 in auxiliary mechanism. It takes approximately 3 seconds.
4. Press the recirculation (REC) and fresh (FRE) switch as desired.
RJIA1971E
Switch LED status of
REC/FRE switch Setting status Setting changeover method
REC ON Manual REC status is memorized. (Initial setting)
REC SW: ON
OFF AUTO control
FRE ON Manual FRE status is memorized.
FRE SW: ON
OFF AUTO control (Initial setting)

Page 499 of 4731

ATC-62
TROUBLE DIAGNOSIS
Revision: 2005 July 2005 FX
CHECKING INTAKE AIR
1. Press recirculation (REC) switch one time. Recirculation indica-
tor should illuminate.
2. Press fresh (FRE) switch one time. Fresh indicator should illumi- nate.
3. Listen for intake door position change. (Slight change of blower sound can be heard.)
If NG, go to trouble diagnosis procedure for AT C - 7 6 , "
Intake Door
Motor Circuit" .
If OK, continue the check.
NOTE:
Confirm that the compressor clutch is engaged (sound or visual
inspection) and intake door position is at FRESH when the D/F or DEF is selected.
CHECKING TEMPERATURE DECREASE
1. Press temperature (DOWN) switch (driver side) until 18 °C
(60 °F) is displayed.
2. Check for cold air at discharge air outlets.
If NG, go to trouble diagnosis procedure for AT C - 9 1 , "
Insufficient
Cooling" .
If OK, continue the check.
CHECKING TEMPERATURE INCREASE
1. Press temperature (UP) switch (driver side) until 32 °C (90 °F) is
displayed.
2. Check for hot air at discharge air outlets.
If NG, go to trouble diagnosis procedure for ATC-100, "
Insufficient
Heating" .
If OK, continue the check.
CHECK A/C SWITCH
1. Press AUTO switch and A/C switch.
2. A/C switch indicator will turn ON.
Confirm that the compressor clutch engages (sound or visual
inspection).
If NG, go to trouble diagnosis procedure for AT C - 8 4 , "
Magnet Clutch
Circuit" .
If OK, continue the check.
RJIA1978E
RJIA1976E
RJIA1977E
RJIA1975E

Page 508 of 4731

TROUBLE DIAGNOSIS ATC-71
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2005 July 2005 FX
SYSTEM DESCRIPTION
Component Parts
Mode door control system components are:
Unified meter and A/C amp.
Mode door motor (LCU)
A/C LAN system (PBR built-in mode door motor, air mix door motor and intake door motor)
In-vehicle sensor
Ambient sensor
Sunload sensor
Intake sensor
System Operation
The unified meter and A/C amp. receives data from each of the sensors. The unified meter and A/C amp.
sends air mix door, mode door and intake door opening angle data to the air mix door motor LCU, mode door
motor LCU and intake door motor LCU.
The air mix door motor, mode door motor and intake door motor read their respective signals according to the
address signal. Opening angle indication signals received from the unified meter and A/C amp. and each of
the motor position sensors are compared by the LCUs in each door motor with the existing decision and open-
ing angles. Subsequently, HOT/COLD, DEF/VENT and FRESH/RECIRCULATION operation is selected. The
new selection data are returned to the unified meter and A/C amp.
RJIA1777E

Page 511 of 4731

ATC-74
TROUBLE DIAGNOSIS
Revision: 2005 July 2005 FX
SYSTEM DESCRIPTION
Component Parts
Air mix door control system components are:
Unified meter and A/C amp.
Air mix door motor (LCU)
A/C LAN system (PBR built-in mode door motor, air mix door motor and intake door motor)
In-vehicle sensor
Ambient sensor
Sunload sensor
Intake sensor
System Operation
The unified meter and A/C amp. receives data from each of the sensors. The unified meter and A/C amp.
sends air mix door, mode door and intake door motor opening angle data to the air mix door motor LCU, mode
door motor LCU and intake door motor LCU.
The air mix door motor, mode door motor and intake door motor read their respective signals according to the
address signal. Opening angle indication signals received from the unified meter and A/C amp. and each of
the motor position sensors are compared by the LCUs in each door motor with the existing decision and open-
ing angles. Subsequently, HOT/COLD, DEF/VENT and FRESH/RECIRCULATION operation is selected. The
new selection data are returned to the unified meter and A/C amp.
Air Mix Door Control Specification
RJIA1781E
RJIA1782E

Page 532 of 4731

TROUBLE DIAGNOSIS ATC-95
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2005 July 2005 FX
PERFORMANCE CHART
Test Condition
Testing must be performed as follows:
Test Reading
Recirculating-to-discharge Air Temperature Table
Ambient Air Temperature-to-operating Pressure Table
Vehicle condition Indoors or in the shade (in a well-ventilated place)
Doors Closed
Door windows Open
Hood Open
TEMP. Max. COLD
Mode switch (Ventilation) set
Recirculation (REC) switch (Recirculation) set
Fan (blower) speed Max. speed set
Engine speed Idle speed
Operate the air conditioning system for 10 minutes before taking measurements.
Inside air (Recirculating air) at blower assembly inlet Discharge air temperature at center ventilator
° C ( °F)
Relative humidity
% Air temperature
° C ( °F)
50 - 60 20 (68) 11.2 - 13.2 (52 - 56)
25 (77) 12.2 - 14.8 (54 - 59)
30 (86) 15.5 - 18.6 (60 - 65)
35 (95) 21.0 - 24.5 (70 - 76)
40 (104) 28.7 - 32.6 (84 - 91)
60 - 70 20 (68) 13.2 - 15.2 (56 - 59)
25 (77) 14.8 - 17.3 (59 - 63)
30 (86) 18.6 - 21.6 (65 - 71)
35 (95) 24.5 - 28.0 (76 - 82)
40 (104) 32.6 - 36.5 (91 - 98)
Ambient air High-pressure (Discharge side)
kPa (kg/cm
2 , psi) Low-pressure (Suction side)
kPa (kg/cm2 , psi)
Relative humidity
% Air temperature
° C ( °F)
50 - 70 20 (68)
961 - 1,167
(9.8 - 11.9, 139 - 169) 216 - 265
(2.2 - 2.7, 31 - 38)
25 (77) 1,108 - 1,353
(11.3 - 13.8, 161 - 196) 230 - 281
(2.3 - 2.9, 33 - 41)
30 (86) 1,275 - 1,549
(13.0 - 15.8, 185 - 225) 261 - 320
(2.7 - 3.3, 38 - 46)
35 (95) 1,549 - 1,893
(15.8 - 19.3, 225 - 274) 297 - 364
(3.0 - 3.7, 43 - 53)
40 (104) 1,814 - 2,216
(18.5 - 22.6, 263 - 321) 357 - 435
(3.6 - 4.4, 52 - 63)

Page 597 of 4731

ATC-160
REFRIGERANT LINES
Revision: 2005 July 2005 FX
CHECKING PROCEDURE
To prevent inaccurate or false readings, make sure there is no refrigerant vapor, shop chemicals, or cigarette
smoke in the vicinity of the vehicle. Perform the leak test in calm area (low air/wind movement) so that the
leaking refrigerant is not dispersed.
1. Stop engine.
2. Connect a suitable A/C manifold gauge set to the A/C service ports.
3. Check if the A/C refrigerant pressure is at least 345 kPa (3.52 kg/cm
2 , 50 psi) above 16 °C (61 °F). If less
than specification, recover/evacuate and recharge the system with the specified amount of refrigerant.
NOTE:
At temperatures below 16 °C (61 °F), leaks may not be detected since the system may not reach 345 kPa
(3.52 kg/cm
2 , 50 psi).
4. Perform the leak test from the high-pressure side (compressor discharge a to evaporator inlet h) to the low-pressure side [evaporator drain hose i to shaft seal o (VK45DE) or n (VQ35DE)]. Refer to ATC-140,
"Components" . Perform a leak check for the following areas carefully. Clean the component to be
checked and move the leak detected probe completely around the connection/component.
Compressor
Check the fitting of high- and low-pressure flexible hoses, relief valve and shaft seal.
Condenser
Check the fitting of high-pressure flexible hose and pipe, refrigerant pressure sensor.
Liquid tank
Check the refrigerant connection.
Service valves
Check all around the service valves. Ensure service valve caps are secured on the service valves (to pre-
vent leaks).
NOTE:
After removing A/C manifold gauge set from service valves, wipe any residue from valves to prevent any
false readings by leak detector.
Cooling unit (Evaporator)
With engine OFF, turn blower fan on “High” for at least 15 seconds to dissipate any refrigerant trace in the
cooling unit. Wait a minimum of 10 minutes accumulation time (refer to the manufacturer’s recommended
procedure for actual wait time) before inserting the leak detector probe into the drain hose.
Keep the probe inserted for at least 10 seconds. Use caution not to contaminate the probe tip with water
or dirt that may be in the drain hose.
5. If a leak detector detects a leak, verify at least once by blowing compressed air into area of suspected leak, then repeat check as outlined above.
6. Do not stop when one leak is found. Continue to check for additional leaks at all system components. If no leaks are found, perform steps 7-10.
7. Start engine.
8. Set the heater A/C control as follows;
a. A/C switch: ON
b. Mode door position: VENT (Ventilation)
c. Intake position: Recirculation
d. Temperature setting: Max cold
e. Fan speed: High
9. Run engine at 1,500 rpm for at least 2 minutes.
10. Stop engine and perform leak check again following steps 4 through 6 above.
Refrigerant leaks should be checked immediately after stopping
the engine. Begin with the leak detector at the compressor. The
pressure on the high-pressure side will gradually drop after
refrigerant circulation stops and pressure on the low-pressure
side will gradually rise, as shown in the graph. Some leaks are
more easily detected when pressure is high.
SHA839E