sensor INFINITI FX35 2006 Service Manual
Page 4255 of 4462
SUPPLEMENTAL RESTRAINT SYSTEM (SRS) SRS-7
C
D E
F
G
I
J
K L
M A
B
SRS
Revision: 2006 December 2006 FX35/FX45
Occupant Classification System (OCS)NHS0009O
The occupant classification system identifies different size occupants, out of position occupants, and detects if
child seat is present in the front passenger seat. The occupant classification system receives inputs from the
occupant classification sensor (located inside the passenger seat cushion assembly) and belt tension sensor
(part of the passenger front seat belt assembly and located at the belt anchor location). Depending on classifi-
cation of passenger, the occupant classification system sends a signal to the diagnosis sensor unit. The diag-
nosis sensor unit uses this signal to determine full, partial, or non deployment of passenger front air bag in the
event of a collision. Depending on the signal received, the diagnosis sensor unit can disable the passenger
front air bag completely.
NOTE:
In case of customer concern, CONSULT-ll can be used to confirm the passenger air bag status (readiness).
Passenger Air Bag Status Condition NHS0009P
NOTE:
Passenger does not meet Ocuupant classification System specifications for passenger air bag activation.
Component Parts of Occupant Classification System NHS0009Q
Front Passenger Seat
(Condition) PASS AIR BAG OFF Indicator
(Status) Passenger Air Bag Status
(Readiness) CONSULT-ll Display
Seat occupied OFF Active (enabled) ON
seat occupiedNOTE ON Deactivated (disabled) OFF
Seat empty OFF Deactivated (disabled) OFF
PHIA1334E
1. Occupant classification system con-
trol unit 2.
Occupant classification system sen-
sor 3. Bladder
4. Front passenger air bag OFF indica-
tor (Cutoff telltaile)
Page 4258 of 4462
SRS-10
TROUBLE DIAGNOSIS
Revision: 2006 December 2006 FX35/FX45
Component Parts LocationNHS0007B
PHIA1335E
1. Driver air bag module 2. Front passenger air bag module 3. Spiral cable
4. Front side air bag module 5. Diagnosis sensor unit 6. Side air bag (Satellite) sensors
7. Seat belt pre-tensioners 8. Seat belt buckle switch 9. Side curtain air bag module
10. Crash zone sensor 11. Occupant classification system sen-
sor 12.Occupant classification system con-
trol unit
Page 4265 of 4462
TROUBLE DIAGNOSIS SRS-17
C
D E
F
G
I
J
K L
M A
B
SRS
Revision: 2006 December 2006 FX35/FX45
CONSULT-II FunctionNHS0007E
DIAGNOSIS MODE FOR CONSULT-II
“SELF-DIAG [CURRENT]”
A current self-diagnostic results (also indicated by the number of warning lamp flashes in the Diagnosis
mode) is displayed on the CONSULT-II screen in real time. This refers to a malfunctioning part requiring
repairs.
“SELF-DIAG [PAST]”
Diagnosis results previously stored in the memory are displayed on the CONSULT-II screen. The stored
results are not erased until memory erasing is executed.
“TROUBLE DIAG RECORD”
With TROUBLE DIAG RECORD, diagnosis results previously erased by a reset operation can be dis-
played on the CONSULT-II screen.
“ECU DISCRIMINATED NO.”
The diagnosis sensor unit for each vehicle model is assigned
with its own, individual classification number. This number will
be displayed on the CONSULT-II screen, as shown. When
replacing the diagnosis sensor unit, refer to the part number for
the compatibility. After installation, replacement with a correct
unit can be checked by confirming this classification number on
the CONSULT-II screen.
After repair, make sure the discriminated number of diagnosis
sensor unit installed to vehicle are same. Refer to SRS-49,
"ECU DISCRIMINATED NO." .
HOW TO CHANGE SELF-DIAGNOSIS MODE WITH CONSULT-II
From User Mode to Diagnosis Mode
After selecting “AIR BAG” on the “SELECT SYSTEM” screen, User mode automatically changes to Diagnosis
mode.
From Diagnosis Mode to User Mode
To return to User mode from Diagnosis mode, touch “BACK” key of CONSULT-II until “SELECT SYSTEM”
appears, then diagnosis mode automatically changes to User mode.
PHIA0218E
SRS803
SRS804
Page 4268 of 4462
SRS-20
TROUBLE DIAGNOSIS
Revision: 2006 December 2006 FX35/FX45
Warning lamp examples
“AIR BAG” warning lamp operation — User mode
— SRS condition Reference item
No malfunction is detected.
No further action is necessary. —
The system is malfunctioning and
needs to be repaired as indicated. Go to
SRS-21, "DIAGNOSTIC
PROCEDURE 2" or SRS-27,
"DIAGNOSTIC PROCEDURE 5" .
Air bag is deployed.
Seat belt pre-tensioner is deployed. Go to
SRS-50, "
COLLISION DIAG-
NOSIS" .
Diagnosis sensor unit is malfunction-
ing.
Air bag power supply circuit is mal-
functioning.
SRS air bag warning lamp circuit is
malfunctioning. Go to
SRS-36, "
Trouble Diagnosis:
“AIR BAG” Warning Lamp Does Not
Turn OFF" .
Diagnosis sensor unit is malfunction-
ing.
Air bag warning lamp circuit is mal-
functioning. Go to
SRS-37, "
Trouble Diagnosis:
“AIR BAG” Warning Lamp Does Not
Turn ON" .
SHIA0011E
SHIA0012E
SHIA0013E
SHIA0014E
Page 4270 of 4462
SRS-22
TROUBLE DIAGNOSIS
Revision: 2006 December 2006 FX35/FX45
CONSULT-II Diagnostic Code Chart (“SELF-DIAG [CURRENT]”)
Diagnostic item Explanation Repair order
“Recheck SRS at each replacement”
NO DTC IS
DETECTED. When malfunction is
indicated by the “AIR
BAG” warning lamp in
User mode.
Low battery voltage (Less than 9V)Go to SRS-25, "DIAGNOSTIC PRO-
CEDURE 3" after charging the bat-
tery.
Self-diagnostic result “SELF-DIAG
[PAST]” (previously stored in the
memory) might not be erased after
repair.
Intermittent malfunction has been
detected in the past.
Go to SRS-27, "DIAGNOSTIC PRO-
CEDURE 4 (CONTINUED FROM
DIAGNOSTIC PROCEDURE 2)" .
Go to SRS-27, "DIAGNOSTIC PRO-
CEDURE 5" .
No malfunction is detected. —
DRIVER AIR BAG
MODULE
[OPEN]
Driver air bag module circuit is open (including the spiral cable). 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. Replace the driver air bag module.
4. Replace the spiral cable.
5. Replace the diagnosis sensor unit.
6. Replace the related harness.
DRIVER AIR BAG
MODULE
[VB-SHORT]
Driver air bag module circuit is shorted to a power supply circuit
(including the spiral cable).
DRIVER AIR BAG
MODULE
[GND-SHORT]
Driver air bag module circuit is shorted to ground (including the
spiral cable).
DRIVER AIR BAG
MODULE
[SHORT]
Driver air bag module circuit is shorted between lines.
ASSIST A/B MODULE
[OPEN]
Front passenger air bag module circuit is open. 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. Replace the front passenger air bag module.
4. Replace the diagnosis sensor unit.
5. Replace the related harness.
ASSIST A/B MODULE
[VB-SHORT]
Front passenger air bag module circuit is shorted to a power
supply circuit.
ASSIST A/B MODULE
[GND-SHORT]
Front passenger air bag module circuit is shorted to ground.
ASSIST A/B MODULE
[SHORT]
Front passenger air bag module circuit is shorted between lines.
CRASH ZONE SEN
[UNIT FAIL]
CRASH ZONE SEN
[COMM FAIL]
Crash zone sensor 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. Replace the crash zone sensor.
4. Replace the diagnosis sensor unit.
5. Replace the related harness.
SIDE MODULE LH
[OPEN]
Front LH side air bag module circuit is open. 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. Replace the front LH seatback assembly (front LH side air bag
module).
4. Replace the diagnosis sensor unit.
5. Replace the related harness.
SIDE MODULE LH
[VB-SHORT]
Front LH side air bag module circuit is shorted to a power sup-
ply circuit.
SIDE MODULE LH
[GND-SHORT]
Front LH side air bag module circuit is shorted to ground.
SIDE MODULE LH
[SHORT]
Front LH side air bag module circuit is shorted between lines.
Page 4271 of 4462
TROUBLE DIAGNOSIS SRS-23
C
D E
F
G
I
J
K L
M A
B
SRS
Revision: 2006 December 2006 FX35/FX45
SIDE MODULE RH
[OPEN]Front RH side air bag module circuit is open. 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. Replace the front RH seatback assembly (front RH side air bag
module).
4. Replace the diagnosis sensor unit.
5. Replace the related harness.
SIDE MODULE RH
[VB-SHORT]
Front RH side air bag module circuit is shorted to a power sup-
ply circuit.
SIDE MODULE RH
[GND-SHORT]
Front RH side air bag module circuit is shorted to ground.
SIDE MODULE RH
[SHORT]
Front RH side air bag module circuit is shorted between lines.
SATELLITE SENS LH
[UNIT FAIL]
SATELLITE SENS LH
[COMM FAIL]
LH side air bag (Satellite) sensor 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. Replace the LH side air bag (Satel- lite) sensor.
4. Replace the diagnosis sensor unit.
5. Replace the related harness.
SATELLITE SENS RH
[UNIT FAIL]
SATELLITE SENS RH
[COMM FAIL]
RH side air bag (Satellite) sensor 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. Replace the RH side air bag (Satel- lite) sensor.
4. Replace the diagnosis sensor unit.
5. Replace the related harness.
PRE-TEN FRONT LH
[OPEN]
Front LH pre-tensioner circuit is open. 1. Visually check the wiring harness
connections.
2. Replace the harness if it has visible damage.
3. Replace the front LH seat belt.
4. Replace the diagnosis sensor unit.
5. Replace the related harness.
PRE-TEN FRONT LH
[VB-SHORT]
Front LH pre-tensioner circuit is shorted to a power supply cir-
cuit.
PRE-TEN FRONT LH
[GND-SHORT]
Front LH pre-tensioner circuit is shorted to ground.
PRE-TEN FRONT LH
[SHORT]
Front LH pre-tensioner circuit is shorted between lines.
PRE-TEN FRONT RH
[OPEN]
Front RH pre-tensioner circuit is open. 1. Visually check the wiring harness
connections.
2. Replace the harness if it has visible damage.
3. Replace the front RH seat belt.
4. Replace the diagnosis sensor unit.
5. Replace the related harness.
PRE-TEN FRONT RH
[VB-SHORT]
Front RH pre-tensioner circuit is shorted to a power supply cir-
cuit.
PRE-TEN FRONT RH
[GND-SHORT]
Front RH pre-tensioner circuit is shorted to ground.
PRE-TEN FRONT RH
[SHORT]
Front RH pre-tensioner circuit is shorted between lines.
CURTAIN MODULE LH
[OPEN]
LH side curtain air bag module circuit is open. 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. Replace the LH side curtain air bag module.
4. Replace the diagnosis sensor unit.
5. Replace the related harness.
CURTAIN MODULE LH
[VB-SHORT]
LH side curtain air bag module circuit is shorted to a power sup-
ply circuit.
CURTAIN MODULE LH
[GND-SHORT]
LH side curtain air bag module circuit is shorted to ground.
CURTAIN MODULE LH
[SHORT]
LH side curtain air bag module circuit is shorted between lines.
Diagnostic item Explanation
Repair order
“Recheck SRS at each replacement”
Page 4272 of 4462
SRS-24
TROUBLE DIAGNOSIS
Revision: 2006 December 2006 FX35/FX45
NOTE:
Follow the procedures in numerical order when repairing malfunctioning parts. Confirm whether malfunction is
eliminated using air bag warning lamp or CONSULT-II each time repair is finished. If malfunction is still
observed, proceed to the next step. When malfunction is eliminated, further repair work is not required.
CURTAIN MODULE RH
[OPEN]RH side curtain air bag module circuit is open. 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. Replace the RH side curtain air bag module.
4. Replace the diagnosis sensor unit.
5. Replace the related harness.
CURTAIN MODULE RH
[VB-SHORT]
RH side curtain air bag module circuit is shorted to a power sup-
ply circuit.
CURTAIN MODULE RH
[GND-SHORT]
RH side curtain air bag module circuit is shorted to ground.
CURTAIN MODULE RH
[SHORT]
RH side curtain air bag module circuit is shorted between lines.
CONTROL UNIT
Diagnosis sensor unit is malfunctioning. 1. Visually check the wiring harness connection.
2. Replace the diagnosis sensor unit.
PASS A/B INDCTR
CKT
Cutoff telltale circuit is open or shorted to grand or the circuits
are shorted each other. 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. Replace cutoff telltale.
4. Replace the diagnosis sensor unit.
OCCUPANT SENS C/U
[UNIT FAIL]
Trouble occurs in Occupant Classification System-CU.Replace passenger side seat cush-
ion assembly.
OCCUPANT SENS
[UNIT FAIL]
Trouble occurs in Occupant Classification System-SENS.Replace passenger side seat cush-
ion assembly.
BELT TENSION SENS
[UNIT FAIL]
Trouble occurs in Belt Tension sensor (BTS), circuit of BTS—
Occupant Classification System-CU, or Occupant Classification
System-CU. 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. Replace passenger side seat belt assembly.
4. Replace the diagnosis sensor unit.
OCCUPANT SENS C/U
[COMM FAIL]
Trouble occurs in Occupant Classification System-CU, circuit of
Occupant Classification System-CU—Diagnosis Senser Unit, or
Diagnosis Sensor Unit. 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. Replace passenger side seat cush- ion assembly.
4. Replace the diagnosis sensor unit.
FRONTAL COLLISION-
DETECTION
Seat belt pre-tensioner and front air bag are deployed.Go to SRS-50, "For Frontal Colli-
sion" .
SIDE COLLISION
DETECTION
Side and curtain air bag is deployed.Go to SRS-52, "For Side Collision" .
Diagnostic item Explanation
Repair order
“Recheck SRS at each replacement”
Page 4276 of 4462
SRS-28
TROUBLE DIAGNOSIS
Revision: 2006 December 2006 FX35/FX45
3. Touch “TROUBLE DIAG RECORD”. NOTE:
With “TROUBLE DIAG RECORD”, diagnosis results previously
erased by a reset operation can be displayed.
4. Diagnostic code is displayed on “TROUBLE DIAG RECORD”.
5. Touch “PRINT”.
6. Compare diagnostic codes to SRS-27, "
DIAGNOSTIC PROCE-
DURE 5" .
7. Touch “BACK” key of CONSULT-II until “SELECT SYSTEM” appears.
8. Turn ignition switch OFF, then turn off and disconnect CON- SULT-II, and both battery cables.
9. Repair the system as outlined by the “Repair order” in “Intermit- tent Malfunction Diagnostic Code Chart”, that corresponds to the
self-diagnostic result. For replacement procedure of component
parts, refer to the Removal and Installation procedure for the appropriate component.
10. Go to SRS-25, "
DIAGNOSTIC PROCEDURE 3" , for final inspection.
CONSULT-II Diagnostic Code Chart (“SELF-DIAG [PAST]” or “TROUBLE DIAG RECORD”)
SRS697
SHIA0182E
Diagnostic item Explanation Repair order
“Recheck SRS at each replacement”
NO DTC IS
DETECTED. When malfunction is
indicated by the “AIR
BAG” warning lamp in
User mode.
Low battery voltage (Less than 9V)Go to SRS-25, "DIAGNOSTIC PRO-
CEDURE 3" .
No malfunction is detected.Go to SRS-25, "DIAGNOSTIC PRO-
CEDURE 3" .
DRIVER AIR BAG
MODULE
[OPEN]
Driver air bag module circuit is open (including the spiral cable). 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. If the harness check result is OK, replace driver air bag module, diag-
nosis sensor unit and spiral cable.
DRIVER AIR BAG
MODULE
[VB-SHORT]
Driver air bag module circuit is shorted to a power supply circuit
(including the spiral cable).
DRIVER AIR BAG
MODULE
[GND-SHORT]
Driver air bag module circuit is shorted to ground (including the
spiral cable).
DRIVER AIR BAG
MODULE
[SHORT]
Driver air bag module circuit is shorted between lines.
ASSIST A/B MODULE
[OPEN]
Front passenger air bag module circuit is open. 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. If the harness check result is OK, replace the diagnosis sensor unit
and front passenger air bag module.
ASSIST A/B MODULE
[VB-SHORT]
Front passenger air bag module circuit is shorted to a power
supply circuit.
ASSIST A/B MODULE
[GND-SHORT]
Front passenger air bag module circuit is shorted to ground.
ASSIST A/B MODULE
[SHORT]
Front passenger air bag module circuit is shorted between lines.
Page 4277 of 4462
TROUBLE DIAGNOSIS SRS-29
C
D E
F
G
I
J
K L
M A
B
SRS
Revision: 2006 December 2006 FX35/FX45
CRASH ZONE SEN
[UNIT FAIL]
CRASH ZONE SEN
[COMM FAIL]Crash zone sensor 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. If the harness check result is OK, replace crash zone sensor and diag-
nosis sensor unit.
SIDE MODULE LH
[OPEN]
Front LH side air bag module circuit is open. 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. If the harness check result is OK, replace the diagnosis sensor unit
and LH side air bag module.
SIDE MODULE LH
[VB-SHORT]
Front LH side air bag module circuit is shorted to a power sup-
ply circuit.
SIDE MODULE LH
[GND-SHORT]
Front LH side air bag module circuit is shorted to ground.
SIDE MODULE LH
[SHORT]
Front LH side air bag module circuit is shorted between lines.
SIDE MODULE RH
[OPEN]
Front RH side air bag module circuit is open. 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. If the harness check result is OK, replace the diagnosis sensor unit
and RH side air bag module.
SIDE MODULE RH
[VB-SHORT]
Front RH side air bag module circuit is shorted to a power sup-
ply circuit.
SIDE MODULE RH
[GND-SHORT]
Front RH side air bag module circuit is shorted to ground.
SIDE MODULE RH
[SHORT]
Front RH side air bag module circuit is shorted between lines.
SATELLITE SENS LH
[UNIT FAIL]
SATELLITE SENS LH
[COMM FAIL]
LH side air bag (Satellite) sensor 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. If the harness check result is OK, replace the diagnosis sensor unit
and LH side air bag (Satellite) sen-
sor.
SATELLITE SENS RH
[UNIT FAIL]
SATELLITE SENS RH
[COMM FAIL]
RH side air bag (Satellite) sensor 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. If the harness check result is OK, replace the diagnosis sensor unit
and RH side air bag (Satellite) sen-
sor.
PRE-TEN FRONT LH
[OPEN]
Front LH pre-tensioner circuit is open. 1. Visually check the wiring harness
connections.
2. Replace the harness if it has visible damage.
3. If the harness check result is OK, replace the diagnosis sensor unit
and front LH seat belt.
PRE-TEN FRONT LH
[VB-SHORT]
Front LH pre-tensioner circuit is shorted to a power supply cir-
cuit.
PRE-TEN FRONT LH
[GND-SHORT]
Front LH pre-tensioner circuit is shorted to ground.
PRE-TEN FRONT LH
[SHORT]
Front LH pre-tensioner circuit is shorted between lines.
Diagnostic item Explanation
Repair order
“Recheck SRS at each replacement”
Page 4278 of 4462
SRS-30
TROUBLE DIAGNOSIS
Revision: 2006 December 2006 FX35/FX45
PRE-TEN FRONT RH
[OPEN]Front RH pre-tensioner circuit is open. 1. Visually check the wiring harness
connections.
2. Replace the harness if it has visible damage.
3. If the harness check result is OK, replace the diagnosis sensor unit
and front RH seat belt.
PRE-TEN FRONT RH
[VB-SHORT]
Front RH pre-tensioner circuit is shorted to a power supply cir-
cuit.
PRE-TEN FRONT RH
[GND-SHORT]
Front RH pre-tensioner circuit is shorted to ground.
PRE-TEN FRONT RH
[SHORT]
Front RH pre-tensioner circuit is shorted between lines.
CURTAIN MODULE LH
[OPEN]
LH side curtain air bag module circuit is open. 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. If the harness check result is OK, replace the diagnosis sensor unit
and LH side curtain air bag module.
CURTAIN MODULE LH
[VB-SHORT]
LH side curtain air bag module circuit is shorted to a power sup-
ply circuit.
CURTAIN MODULE LH
[GND-SHORT]
LH side curtain air bag module circuit is shorted to ground.
CURTAIN MODULE LH
[SHORT]
LH side curtain air bag module circuit is shorted between lines.
CURTAIN MODULE RH
[OPEN]
RH side curtain air bag module circuit is open. 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. If the harness check result is OK, replace the diagnosis sensor unit
and RH side curtain air bag module.
CURTAIN MODULE RH
[VB-SHORT]
RH side curtain air bag module circuit is shorted to a power sup-
ply circuit.
CURTAIN MODULE RH
[GND-SHORT]
RH side curtain air bag module circuit is shorted to ground.
CURTAIN MODULE RH
[SHORT]
RH side curtain air bag module circuit is shorted between lines.
CONTROL UNIT
Diagnosis sensor unit is malfunctioning. 1. Visually check the wiring harness connection.
2. Replace the diagnosis sensor unit.
PASS A/B INDCTR
CKT
Cutoff telltale circuit is open or shorted to grand or the circuits
are shorted each other. 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. Replace cutoff telltale.
4. Replace the diagnosis sensor unit.
OCCUPANT SENS C/U
[UNIT FAIL]
Trouble occurs in Occupant Classification System-CU.Replace passenger side seat cush-
ion assembly.
OCCUPANT SENS
[UNIT FAIL]
Trouble occurs in Occupant Classification System-SENS.Replace passenger side seat cush-
ion assembly.
BELT TENSION SENS
[UNIT FAIL]
Trouble occurs in Belt Tension sensor (BTS), circuit of BTS—
Occupant Classification System-CU, or Occupant Classification
System-CU. 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible damage.
3. Replace passenger side seat belt assembly.
4. Replace the diagnosis sensor unit.
Diagnostic item Explanation
Repair order
“Recheck SRS at each replacement”