ECU INFINITI M35 2007 Factory Service Manual
Page 1377 of 4647
CO-16
[VQ35DE]
RADIATOR
Revision: 2007 April2007 M35/M45
Minimize the lift of A/C condenser to prevent load from being applied to A/C piping.
e. After removing the radiator, place the A/C condenser on the radiator core support to prevent load from
being applied to piping. And then, temporarily secure them using a rope to prevent them from being
dropped.
INSTALLATION
Installation is the reverse order of removal.
INSPECTION AFTER INSTALLATION
Check for leaks of engine coolant using the radiator cap tester adapter (commercial service tool) and the
radiator cap tester (commercial service tool). Refer to CO-11, "
LEAK CHECK" .
Start and warm up the engine. Visually make sure that there is no leaks of engine coolant and A/T fluid.
Checking Radiator CapNBS004QU
Check valve seat of radiator cap.
–Check if valve seat is swollen to the extent that the edge of the
plunger cannot be seen when watching it vertically from the top.
–Check if valve seat has no soil and damage.
Pull negative-pressure valve to open it, and make sure that it
close completely when released.
–Make sure that there is no dirt or damage on the valve seat of
radiator cap negative-pressure valve.
–Make sure that there are no unusualness in the opening and
closing conditions of negative-pressure valve.
Check radiator cap relief pressure.
–When connecting radiator cap to the radiator cap tester (com-
mercial service tool) (A) and the radiator cap tester adapter
(commercial service tool) (B), apply engine coolant to the cap
seal surface.
Replace radiator cap if there is an unusualness related to the above three.
CAUTION:
When installing radiator cap, thoroughly wipe out the radiator filler neck to remove any waxy residue
or foreign material.
Checking RadiatorNBS004QV
Check radiator for mud or clogging. If necessary, clean radiator as follows.
PBIC2816E
SMA967B
Standard:
78 - 98 kPa (0.8 - 1.0 kg/cm
2 , 11 - 14 psi)
Limit:
59 kPa (0.6 kg/cm
2 , 9 psi)
PBIC5122J
Page 1382 of 4647
RADIATOR (ALUMINUM TYPE)
CO-21
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
CO
Revision: 2007 April2007 M35/M45
4. Make sure that the rim is completely crimped down.
5. Make sure that there is no leakage. Refer to CO-21, "
INSPECTION" .
INSPECTION
1. Apply pressure with the radiator cap tester adapter (commercial
service tool) (A) and the radiator cap tester (commercial service
tool).
WARNING:
To prevent the risk of hose coming undone while under
pressure, securely fasten it down with hose clamp.
CAUTION:
Attach hose to A/T fluid cooler to seal its inlet and outlet.
2. Check for leakage by soaking radiator in water container with
the testing pressure applied.Standard height “H” : 8.0 - 8.4 mm (0.315 - 0.331 in)
SLC554A
Testing pressure
: 157 kPa (1.6 kg/cm
2 , 23 psi)
PBIC5327E
SLC934
Page 1384 of 4647
COOLING FAN
CO-23
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
CO
Revision: 2007 April2007 M35/M45
NOTE:
Cooling fans are controlled by cooling fan control module. For details, refer to EC-499, "
DTC P1217 ENGINE
OVER TEMPERATURE" .
Disassembly and Assembly NBS004R0
DISASSEMBLY
1. Disconnect sub-harness from fan motor (RH and LH) and cooling fan control module.
2. Remove cooling fan control module from fan shroud.
CAUTION:
Handle carefully to avoid dropping and shocks.
3. Remove cooling fan mounting nuts, and then remove the cooling fan (RH and LH).
4. Remove fan motor (RH and LH).
INSPECTION AFTER DISASSEMBLY
Cooling Fan
Inspect cooling fan for crack or unusual bend.
If anything is found, replace cooling fan.
ASSEMBLY
Note the following, and assemble in the reverse order of disassembly.
CAUTION:
RH and LH cooling fans are different. Be careful not to misassemble them.
Install each fan in the following position.
Secure the sub-harness tightly to the fan shroud to prevent the fan rotation area from being loose.Right side : 4 blades
Left side : 5 blades
Page 1385 of 4647
CO-24
[VQ35DE]
WATER PUMP
Revision: 2007 April2007 M35/M45
WATE R P U M PPFP:21020
ComponentsNBS004R1
Removal and InstallationNBS004R2
CAUTION:
When removing water pump assembly, be careful not to get engine coolant on drive belts.
Water pump cannot be disassembled and should be replaced as a unit.
After installing water pump, connect hose and clamp securely, then check for leaks using the radi-
ator cap tester (commercial service tool) and the radiator cap tester adapter (commercial service
tool).
REMOVAL
1. Remove engine room cover (RH and LH). Refer to EM-15, "ENGINE ROOM COVER" .
2. Remove air duct (inlet) and air cleaner case assembly. Refer to EM-19, "
AIR CLEANER AND AIR DUCT"
.
3. Remove front engine undercover with power tool.
4. Remove drive belts. Refer to EM-16, "
DRIVE BELTS" .
5. Drain engine coolant from radiator. Refer to CO-11, "
Changing Engine Coolant" .
CAUTION:
Perform this step when the engine is cold.
Do not spill engine coolant on drive belts.
6. Remove water drain plug (front) on water pump side of cylinder
block to drain engine coolant from engine inside.
7. Remove chain tensioner cover and water pump cover from front timing chain case.
1. Timing chain tensioner (primary) 2. Chain tensioner cover 3. Water pump cover
4. Water pump 5. O-rings 6. Water drain plug (front)
SBIA0482E
PBIC2662E
Page 1386 of 4647
WATER PUMP
CO-25
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
CO
Revision: 2007 April2007 M35/M45
U s e t h e s e a l c u t t e r [ S S T: K V 1 0 1111 0 0 ( J 3 7 2 2 8 ) ] t o c u t l i q u i d g a s k e t f o r r e m o v a l .
8. Remove timing chain tensioner (primary) as follows:
a. Remove lower mounting bolt.
CAUTION:
Be careful not to drop mounting bolt inside timing chain
case.
b. Loosen upper mounting bolt slowly, and then turn chain ten-
sioner (primary) on the mounting bolt so that plunger is fully
expanded.
NOTE:
Even if plunger is fully expanded, it is not dropped from the body
of timing chain tensioner (primary).
c. Turn crankshaft pulley clockwise so that timing chain on the tim-
ing chain tensioner (primary) side is loose.
d. Remove upper mounting bolt, and then remove timing chain ten-
sioner (primary).
CAUTION:
Be careful not to drop mounting bolt inside timing chain
case.
9. Remove water pump as follows:
a. Remove three water pump mounting bolts. Secure a gap
between water pump gear and timing chain, by turning crank-
shaft pulley counterclockwise until timing chain looseness on
water pump sprocket becomes maximum.
PBIC3575E
PBIC4820E
PBIC3576E
PBIC1193E
Page 1388 of 4647
WATER PUMP
CO-27
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
CO
Revision: 2007 April2007 M35/M45
a. Turn crankshaft pulley clockwise so that timing chain on the tim-
ing chain tensioner (primary) side is loose.
b. Pull plunger stopper tab up (or turn lever downward) so as to
remove plunger stopper tab from the ratchet of plunger.
NOTE:
Plunger stopper tab and lever are synchronized.
c. Push plunger into the inside of tensioner body.
d. Hold plunger in the fully compressed position by engaging
plunger stopper tab with the tip of ratchet.
e. To secure lever, insert stopper pin through hole of lever into ten-
sioner body hole.
The lever parts and the tab are synchronized. Therefore, the
plunger will be secured under this condition.
NOTE:
Figure shows the example of 1.2 mm (0.047 in) diameter thin screwdriver being used as the stopper pin.
f. Install timing chain tensioner (primary).
Remove dust and foreign material completely from backside of timing chain tensioner (primary) and
from installation area of rear timing chain case.
g. Remove stopper pin.
h. Make sure again that timing chain and water pump sprocket are engaged.
4. Install chain tensioner cover and water pump cover as follows:
a. Before installing, remove all traces of old liquid gasket from mat-
ing surface of water pump cover and chain tensioner cover
using scraper. Also remove traces of old liquid gasket from the
mating surface of front timing chain case.
PBIC1805E
PBIC3568E
PBIC3577E
SLC446B
Page 1393 of 4647
CO-32
[VQ35DE]
WATER OUTLET AND WATER PIPING
Revision: 2007 April2007 M35/M45
9. Remove heater pipe, water bypass hoses and water pipe.
INSTALLATION
Note the following, and install in the reverse order of removal.
Securely insert each hose, and install clamp at a position where it does not interfere with the pipe bulge.
When inserting water pipe into water outlet, apply neutral detergent to O-ring.
INSPECTION AFTER INSTALLATION
Check for leaks of engine coolant using the radiator cap tester adapter (commercial service tool) and the
radiator cap tester (commercial service tool). Refer to CO-11, "
LEAK CHECK" .
Start and warm up the engine. Visually make sure that there is no leaks of engine coolant.
Page 1405 of 4647
CO-44
[VK45DE]
RADIATOR
Revision: 2007 April2007 M35/M45
CAUTION:
Perform this step when the engine is cold.
Do not spill engine coolant on drive belts.
4. Remove the A/C piping bracket from left side member, and then move the A/C piping out of the way.
5. Disconnect A/T fluid cooler hoses from radiator.
Install blind plug to avoid leakage of A/T fluid.
6. Remove radiator hoses (upper and lower) and reservoir tank hose.
CAUTION:
Be careful not to allow engine coolant to contact drive belts.
7. Remove cooling fan assembly (1). Refer to CO-51, "
COOLING
FA N" .
CAUTION:
Do not damage or scratch radiator core when removing.
8. Remove radiator as follows:
a. Remove mount bracket (RH and LH).
b. Pull the radiator (1) rearward from the vehicle, and then remove
the mounting bolts (3) and A/C condenser (2).
NOTE:
Figure shows right side.
c. Lift up and pull the radiator (4) rearward, and then remove the
mounting rubber (lower) (3) from the radiator core support (2).
CAUTION:
At this time, A/C condenser is on the lower end of radiator
front surface. Minimize the movement to the rear side.
d. Lift up the A/C condenser to disengage the lower end of front surface, and then remove the radiator.
CAUTION:
Be careful not to damage radiator and A/C condenser core.
Minimize the lift of A/C condenser to prevent load from being applied to A/C piping.
e. After removing the radiator, place the A/C condenser on the radiator core support to prevent load from
being applied to piping. And then, temporarily secure them using a rope to prevent them from being
dropped.
INSTALLATION
Installation is the reverse order of removal.
KBIA3587J
KBIA3586J
1 : A/C condenser
: Engine front
PBIC3389E
Page 1411 of 4647
CO-50
[VK45DE]
RADIATOR (ALUMINUM TYPE)
Revision: 2007 April2007 M35/M45
4. Make sure that the rim is completely crimped down.
5. Make sure that there is no leakage. Refer to CO-50, "
INSPECTION" .
INSPECTION
1. Apply pressure with radiator cap tester adapter (commercial ser-
vice tool) and radiator cap tester (commercial service tool).
provide used radiator and connect it to tested radiator using
radiator hoses as shown in the figure.
NOTE:
The used radiator should be tested beforehand to confirm it
has no leakage. If used one is not available, it is possible to
use new service part as a radiator testing tool.
WARNING:
To prevent the risk of hose coming undone while under pressure, securely fasten it down with
hose clamp.
CAUTION:
Attach hose to A/T fluid cooler to seal its inlet and outlet.
2. Check for leakage by soaking radiator in water container with
the testing pressure applied.Standard height “H” : 8.0 - 8.4 mm (0.315 - 0.331 in)
SLC554A
Testing pressure
: 157 kPa (1.6 kg/cm
2 , 23 psi)PBIC5158E
PBIC1699E
Page 1413 of 4647
CO-52
[VK45DE]
COOLING FAN
Revision: 2007 April2007 M35/M45
NOTE:
Cooling fans are controlled by cooling fan control module. For details. Refer to EC-1214, "
DTC P1217
ENGINE OVER TEMPERATURE" .
Disassembly and Assembly NBS004RO
DISASSEMBLY
1. Disconnect sub-harness from fan motor (RH and LH) and cooling fan control module.
2. Remove cooling fan control module from fan shroud.
CAUTION:
Handle carefully to avoid dropping and shocks.
3. Remove cooling fan mounting nuts, and then remove the cooling fan (RH and LH).
4. Remove fan motor (RH and LH).
INSPECTION AFTER DISASSEMBLY
Cooling Fan
Inspect cooling fan for crack or unusual bend.
If anything is found, replace cooling fan.
ASSEMBLY
Note the following, and assemble in the reverse order of disassembly.
CAUTION:
RH and LH cooling fans are different. Be careful not to misassemble them.
Install each fan in the following position.
Secure the sub-harness tightly to the fan shroud to prevent the fan rotation area from being loose.Right side : 4 blades
Left side : 5 blades