ignition INFINITI M35 2007 Factory Service Manual
Page 2023 of 4647
EC-494
[VQ35DE]
DTC P0850 PNP SWITCH
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureNBS0052S
1. CHECK DTC WITH TCM
Refer to AT- 4 0 , "
OBD-II Diagnostic Trouble Code (DTC)" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace.
2. CHECK STARTING SYSTEM
Turn ignition switch OFF, then turn it to START.
Does starter motor operate?
Ye s o r N o
Yes >> GO TO 3.
No >> Refer to SC-8, "
STARTING SYSTEM" .
3. CHECK PNP SWITCH INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT-I
1. Turn ignition switch OFF.
2. Disconnect A/T assembly harness connector.
3. Disconnect “unified meter and A/C amp.” harness connector.
4. Check harness continuity between A/T assembly terminal 9 and “unified meter and A/C amp.” terminal 2.
Refer to Wiring Diagram.
5. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M72, F102
Harness for open or short between A/T assembly and “unified meter and A/C amp.”
>> Repair open circuit or short to ground or short to power in harness or connectors.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
102 G PNP switch[Ignition switch: ON]
Selector lever: P or NApproximately 0V
[Ignition switch: ON]
Selector lever: Except aboveBATTERY VOLTAGE
(11 - 14V)
Continuity should exist.
Page 2026 of 4647
DTC P1211 TCS CONTROL UNIT
EC-497
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
DTC P1211 TCS CONTROL UNITPFP:47850
DescriptionNBS0052U
The malfunction information related to TCS is transferred through the CAN communication line from “ABS
actuator and electric unit (control unit)” to ECM.
Be sure to erase the malfunction information such as DTC not only for “ABS actuator and electric unit
(control unit)” but also for ECM after TCS related repair.
On Board Diagnosis LogicNBS0052V
Freeze frame data is not stored in the ECM for this self-diagnosis.
The MIL will not light up for this self-diagnosis.
DTC Confirmation ProcedureNBS0052W
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 10.5V at idle.
WITH CONSULT-II
1. Turn ignition switch ON.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Start engine and let it idle for at least 60 seconds.
4. If 1st trip DTC is detected, go to EC-497, "
Diagnostic Procedure"
.
WITH GST
Follow the procedure “WITH CONSULT-II” above.
Diagnostic ProcedureNBS0052X
Go to BRC-10, "TROUBLE DIAGNOSIS" .
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1211
1211TCS control unitECM receives a malfunction information from
“ABS actuator electric unit (control unit)”
ABS actuator and electric unit (control
unit)
TCS related parts
SEF058Y
Page 2027 of 4647
EC-498
[VQ35DE]
DTC P1212 TCS COMMUNICATION LINE
Revision: 2007 April2007 M35/M45
DTC P1212 TCS COMMUNICATION LINEPFP:47850
DescriptionNBS0052Y
NOTE:
If DTC P1212 is displayed with DTC U1000 or U1001, first perform the trouble diagnosis for DTC
U1000, U1001. Refer to EC-161, "
DTC U1000, U1001 CAN COMMUNICATION LINE" .
If DTC P1212 is displayed with DTC U1010, first perform the trouble diagnosis for DTC U1010.
Refer to EC-164, "
DTC U1010 CAN COMMUNICATION" .
This CAN communication line is used to control the smooth engine operation during the TCS operation. Pulse
signals are exchanged between ECM and “ABS actuator and electric unit (control unit)”.
Be sure to erase the malfunction information such as DTC not only for “ABS actuator and electric unit
(control unit)” but also for ECM after TCS related repair.
On Board Diagnosis LogicNBS0052Z
Freeze frame data is not stored in the ECM for this self-diagnosis.
The MIL will not light up for this self-diagnosis.
DTC Confirmation ProcedureNBS00530
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 10.5V at idle.
WITH CONSULT-II
1. Turn ignition switch ON.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Start engine and let it idle for at least 10 seconds.
4. If 1st trip DTC is detected, go to EC-498, "
Diagnostic Procedure"
.
WITH GST
Follow the procedure “WITH CONSULT-II” above.
Diagnostic ProcedureNBS00531
Go to BRC-10, "TROUBLE DIAGNOSIS" .
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1212
1212TCS communication
lineECM can not receive the information
from “ABS actuator and electric unit (con-
trol unit)” continuously.
Harness or connectors
(The CAN communication line is open or
shorted.)
ABS actuator and electric unit (control unit)
Dead (Weak) battery
SEF058Y
Page 2030 of 4647
DTC P1217 ENGINE OVER TEMPERATURE
EC-501
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
WITH CONSULT-II
1. Check the coolant level in the reservoir tank and radiator.
Allow engine to cool before checking coolant level.
If the coolant level in the reservoir tank and/or radiator is below
the proper range, skip the following steps and go to EC-504,
"Diagnostic Procedure" .
2. Confirm whether customer filled the coolant or not. If customer
filled the coolant, skip the following steps and go to EC-504,
"Diagnostic Procedure" .
3. Turn ignition switch ON.
4. Perform “FAN DUTY CONTROL” in “ACTIVE TEST” mode with
CONSULT-II.
5. Make sure that cooling fan speed varies according to the per-
cent.
6. If the results are NG, go to EC-504, "
Diagnostic Procedure" .
WITH GST
1. Check the coolant level in the reservoir tank and radiator.
Allow engine to cool before checking coolant level.
If the coolant level in the reservoir tank and/or radiator is below
the proper range, skip the following steps and go to EC-504,
"Diagnostic Procedure" .
2. Confirm whether customer filled the coolant or not. If customer
filled the coolant, skip the following steps and go to EC-504,
"Diagnostic Procedure" .
3. Perform IPDM E/R auto active test and check cooling fan motors
operation, refer to PG-23, "
Auto Active Test" .
4. If NG, go to EC-504, "
Diagnostic Procedure" .
SEF621W
PBIB2737E
SEF621W
Page 2033 of 4647
EC-504
[VQ35DE]
DTC P1217 ENGINE OVER TEMPERATURE
Revision: 2007 April2007 M35/M45
Diagnostic ProcedureNBS00537
1. CHECK COOLING FAN OPERATION
With CONSULT-II
1. Turn ignition switch ON.
2. Perform “FAN DUTY CONTROL” in “ACTIVE TEST” mode with
CONSULT-II.
3. Make sure that cooling fan speed varies according to the per-
cent.
Without CONSULT-II
1. Perform IPDM E/R auto active test and check cooling fan motors
operation, refer to PG-23, "
Auto Active Test" .
2. Make sure that cooling fan operates.
OK or NG
OK >> GO TO 2.
NG >> GO TO 5.
2. CHECK COOLING SYSTEM FOR LEAK
Refer to CO-11, "
LEAK CHECK"
OK or NG
OK >> GO TO 3.
NG >> Check the following for leak.
Hose
Radiator
Water pump
3. CHECK COMPONENT PARTS
Check the following.
Radiator cap. Refer to CO-16, "Checking Radiator Cap" .
Thermostat. Refer to CO-29, "WATER INLET AND THERMOSTAT ASSEMBLY" .
Engine coolant temperature sensor. Refer to EC-218, "Component Inspection" .
OK or NG
OK >> GO TO 4.
NG >> Replace malfunctioning component.
4. CHECK MAIN 12 CAUSES
If the cause cannot be isolated, go to EC-507, "
Main 12 Causes of Overheating" .
>>INSPECTION END
PBIB2737E
Page 2034 of 4647
DTC P1217 ENGINE OVER TEMPERATURE
EC-505
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
5. CHECK COOLING FAN CONTROL MODULE POWER SUPPLY CIRCUIT-I
1. Turn ignition switch OFF.
2. Disconnect cooling fan control module (1) harness connector
E42.
–: Vehicle front
–Cooling fan motor-1 (2)
–Cooling fan motor-2 (3)
3. Turn ignition switch ON.
4. Check voltage between cooling fan control module terminal 3
and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 6.
NG >> GO TO 11.
6. CHECK COOLING FAN CONTROL MODULE GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check harness continuity between cooling fan control module terminal 1 and ground.
Refer to wiring diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 7.
NG >> Repair open circuit or short to power in harness or connectors.
7. CHECK IPDM E/R GROUND CIRCUIT
1. Disconnect IPDM E/R harness connector E8, E9.
2. Check harness continuity between IPDM E/R terminal 38, 51 and ground.
Refer to wiring diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 8.
NG >> Repair open circuit or short to power in harness or connectors.
PBIB3352E
Voltage: Battery voltage
PBIA9509J
Continuity should exist.
Continuity should exist.
Page 2035 of 4647
EC-506
[VQ35DE]
DTC P1217 ENGINE OVER TEMPERATURE
Revision: 2007 April2007 M35/M45
8. CHECK COOLING FAN CONTROL SIGNAL CIRCUIT
1. Check harness continuity between IPDM E/R terminal 59 and cooling fan control module terminal 2.
Refer to wiring diagram.
2. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 9.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
9. CHECK COOLING FAN CONTROL MODULE OUTPUT SIGNAL CIRCUIT
1. Reconnect all harness connectors disconnected.
2. Disconnect cooling fan control module harness connectors E301, E303.
3. Turn ignition switch ON.
4. Check voltage between cooling fan control module terminals 4,
6 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 10.
NG >> Replace cooling fan control module.
10. CHECK COOLING FAN MOTORS -1 AND -2
Refer to EC-509, "
Component Inspection" .
OK or NG
OK >> GO TO 15.
NG >> Replace cooling fan motor.
11 . CHECK COOLING FAN CONTROL MODULE POWER SUPPLY CIRCUIT-II
1. Turn ignition switch OFF.
2. Disconnect cooling fan relay harness connector.
3. Turn ignition switch ON.
4. Check voltage between cooling fan relay terminals 1, 3 and
ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 13.
NG >> GO TO 12.Continuity should exist.
Voltage: Battery voltage
PBID0261J
Voltage: Battery voltage
PBIA9511J
Page 2036 of 4647
DTC P1217 ENGINE OVER TEMPERATURE
EC-507
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
12. DETECT MALFUNCTIONING PART
Check the following.
10A fuse
Fuse block (J/B) connector E102
50A fusible link
Harness for open or short between cooling fan relay and fuse
Harness for open or short between cooling fan relay and battery
>> Repair open circuit or short to ground or short to power in harness or connectors.
13. CHECK COOLING FAN CONTROL MODULE POWER SUPPLY CIRCUIT-III
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R harness connector E9.
3. Check harness continuity between the following;
Cooling fan relay terminal 2 and IPDM E/R terminal 56,
Cooling fan relay terminal 5 and cooling fan control module terminal 3.
Refer to wiring diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 14.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
14. CHECK COOLING FAN RELAY
Refer to EC-509, "
Component Inspection" .
OK or NG
OK >> GO TO 15.
NG >> Replace cooling fan relay.
15. CHECK INTERMITTENT INCIDENT
Perform EC-153, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
OK or NG
OK >> Replace IPDM E/R. Refer to PG-18, "IPDM E/R (INTELLIGENT POWER DISTRIBUTION MOD-
ULE ENGINE ROOM)" .
NG >> Repair or replace harness connectors.
Main 12 Causes of OverheatingNBS00538
Continuity should exist.
Engine Step Inspection item Equipment Standard Reference page
OFF 1
Blocked radiator
Blocked condenser
Blocked radiator grille
Blocked bumper
Visual No blocking —
2
Coolant mixtureCoolant tester 50 - 50% coolant mixtureMA-13, "Anti-Freeze
Coolant Mixture Ratio"
3Coolant levelVisual Coolant up to MAX level
in reservoir tank and radi-
ator filler neckMA-15, "Changing
Engine Coolant"
4Radiator capPressure tester 59 - 98 kPa
(0.6 - 1.0 kg/cm2 , 9 - 14
psi) (Limit)CO-16, "
Checking Radia-
tor Cap"
Page 2037 of 4647
EC-508
[VQ35DE]
DTC P1217 ENGINE OVER TEMPERATURE
Revision: 2007 April2007 M35/M45
*1: Turn the ignition switch ON.
*2: Engine running at 3,000 rpm for 10 minutes.
*3: Drive at 90 km/h (55 MPH) for 30 minutes and then let idle for 10 minutes.
*4: After 60 minutes of cool down time.
For more information, refer to CO-7, "
OVERHEATING CAUSE ANALYSIS" . ON*
25Coolant leaksVisual No leaksCO-11, "LEAK CHECK"
ON*26ThermostatTouch the upper and
lower radiator hosesBoth hoses should be hotCO-29, "WATER INLET
AND THERMOSTAT
ASSEMBLY"
ON*17Cooling fanCONSULT-II Operating See trouble diagnosis for
DTC P1217 (EC-499
).
OFF 8
Combustion gas leakColor checker chemical
tester 4 Gas analyzerNegative —
ON*
39Coolant temperature
gaugeVisual Gauge less than 3/4
when driving—
Coolant overflow to
reservoir tankVisual No overflow during driving
and idlingMA-15, "Changing
Engine Coolant"
OFF*410Coolant return from
reservoir tank to radia-
torVisual Should be initial level in
reservoir tankMA-15, "Changing
Engine Coolant"
OFF 11Cylinder headStraight gauge feeler
gauge0.1 mm (0.004 in) Maxi-
mum distortion (warping)EM-102, "CYLINDER
HEAD"
12Cylinder block and pis-
tonsVisual No scuffing on cylinder
walls or pistonEM-124, "CYLINDER
BLOCK"
Engine Step Inspection item Equipment Standard Reference page
Page 2040 of 4647
DTC P1220 FUEL PUMP CONTROL MODULE (FPCM)
EC-511
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
DTC Confirmation ProcedureNBS0053D
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 11V with ignition
switch ON.
WITH CONSULT-II
1. Turn ignition switch ON and select “DATA MONITOR” mode with
CONSULT-II.
2. Make sure that “COOLAN TEMP/S” indicates less than 70°C
(158°F). If not, cool down the engine.
3. Start engine.
4. Hold vehicle at the following conditions for 12 seconds.
5. If 1st trip DTC is detected, go to EC-513, "
Diagnostic Procedure" .
WITH GST
Follow the procedure WITH CONSULT-II above.
ENG SPEED1,550 - 3,250 rpm (AWD models)
1,450 - 3,100 rpm (2WD models)
VHCL SPEED SE 70 - 120 km/h (43 - 75 MPH)
B/FUEL SCHDL Less than 31.8 msec
Selector lever Suitable position
SEF189Y