battery capacity INFINITI QX56 2006 Factory Service Manual

Page 2910 of 3383

BATTERYSC-5
C
DE
F
G H
I
J
L
M A
B
SC
Revision: November 2009 2006 QX56
Remove the cell plug using a suitable tool.
Add distilled water up to the MAX level.
Sulfation
A battery will be completely discharged if it is left unattended
for a long time and the specific gravity will become less than
1.100. This may result in sulfation on the cell plates.
To determine if a battery has been sulfated, note its voltage and
current when charging it. As shown in the figure, less current
and higher voltage are observed in the initial stage of charging
sulfated batteries.
A sulfated battery may sometimes be brought back into service
by means of a long, slow charge, 12 hours or more, followed by
a battery capacity test.
SPECIFIC GRAVITY CHECK
1. Read hydrometer and thermometer indications at eye level.
2. Use the following chart to correct your hydrometer reading
according to electrolyte temperature.
Hydrometer Temperature Correction
MEL043F
PKIA2353E
MEL042FA
Battery electrolyte temperature °C ( °F) Add to specific gravity reading
71 (160) 0.032
66 (150) 0.028
60 (140) 0.024
54 (130) 0.020
49 (120) 0.016
43 (110) 0.012
38 (100) 0.008
32 (90) 0.004
27 (80) 0
21 (70) −0.004
16 (60) −0.008
10 (50) −0.012
4 (40) −0.016
− 1 (30) −0.020
− 7 (20) −0.024

Page 2931 of 3383

SC-26
SERVICE DATA AND SPECIFICATIONS (SDS)
Revision: November 20092006 QX56
SERVICE DATA AND SPECIFICATIONS (SDS)PFP:00030
BatteryEKS00B7M
StarterEKS00B7N
GeneratorEKS00B7O
Ty p eGr. 27
Capacity (20 HR) minimum 12V - 80AH
Cold cranking current A
(For reference value) 710
Application
All models
Manufacturer Mitsubishi
M002T85571ZCKD
Ty p e Reduction gear type
System voltage 12V
No-load Terminal voltage
11V
Current Less than 145A
Revolution More than 3,300 rpm
Minimum diameter of commutator 31.4 mm (1.236 in)
Minimum length of brush 11.0 mm (0.433 in)
Brush spring tension 26.7 - 36.1 N (2.72 - 3.68 kg, 5.93 - 8.02 lb)
Clearance between pinion front edge and
pinion stopper 0.5 - 2.0 mm (0.020 - 0.079 in)
Ty p e LR1130-701
Hitachi
Nominal rating 12V - 130A
Ground polarity Negative
Minimum revolution under no-load (When 13.5 volts is applied) 1,200 rpm
Hot output current (When 13.5 volts is applied) More than 78A/1,800 rpm
More than 108A/2,500 rpm
More than 130A/5,000 rpm
Regulated output voltage 14.1 - 14.7V @ 25°C
Minimum length of brush 6 mm (0.24 in)
Brush spring pressure 1.0 - 3.432 N (0.102 - 0.3501 kg, 0.22 - 0.7715 lbs)
Slip ring minimum outer diameter 26 mm (1.02 in)
Rotor (Field coil) resistance 2.1 ohms