key INFINITI QX60 HYBRID 2014 Dismantling Guide

Page 23 of 50

Primary Procedure
NOTE:Before disconnecting the 12V battery terminal, if necessary, lower the windows, adjust the
steering column, adjust the seats, unlock the doors, etc. Once 12V battery is disconnected,
power controls will not operate.
1. If possible, check the READY
indicator status in the instrument cluster. If it is on, the high
voltage system is active.
2. Place the shift selector in the Park (P) position.
3. Push the ignition switch once to turn OFF the high voltage system. Verify that the READY indicator is off and
then continue to the next steps to open the hood for
12V battery negative cable access.
If the READY indicator does not turn off, refer to
Alter-
nate Procedure 1 (Remove Fuses) (DG–25)
4. If possible, keep the INFINITI Intelligent Key™ at least 5 meters (16 feet) away from the vehicle.
5. Pull release handle (1) and pull up release lever (2) to open hood.
AAYIA0191ZZ
ACC
LOCK
(OFF)
ON
AAYIA0271ZZ
HOLD
AAYIA0315ZZ
DG–23

Page 28 of 50

4. If possible, keep the INFINITI Intelligent Key™ at least 5meters (16 feet) away from the vehicle (except to open
the liftgate as noted below) .
5. Open the liftgate using any of the following: a. liftgate switch on the lower LH side of theinstrument panel.
b. liftgate button on the INFINITI Intelligent Key™ [press for longer than one (1) second].
c. liftgate opener switch (located above license plate)*
HOLD
AAYIA0315ZZ
AAYIA0276ZZ
HOLD
AAYIA0317ZZ
A
AAYIA0266ZZ
DG–28

Page 29 of 50

d. If the liftgate cannot be opened with theinstrument panel switch, liftgate opener switch,
or key fob due to a discharged battery, follow
these steps:
• Remove the cover (A) on the inside of the
liftgate.
• Move the lever (B) as illustrated to open liftgate.
Method Shift Selector Position Ignition Switch Status
a P or N Any
b P OFF
c* Any Any d Any Any
* You must have the INFINITI Intelligent Key™ within approximately 1 meter (3 feet) range of liftgate opener
switch to use the liftgate opener switch function. 6. Open luggage board.
7. Open service plug access cover.
A
B
AAYIA0316ZZ
A
AAYIA0267ZZ
AAYIA0268ZZ
DG–29

Page 33 of 50

Vehicle Cut Sheet









INFINITI Emergency Contact
1-800-662-6200 (US) or 1-800-361-4792 (Canada) Hours of Operation: 8am-5pm (Monday-Friday) Eastern, Central and Pacific Time Zones
High voltage component
or harness (Can be cut
only after the high voltage
system shut-down procedure has been completed.) Never cut electrical
components/batteries
for any reason. Death or serious personal injury will result. Traction Motor
July 2013
Traction Motor
Inverter
High voltage
harness
High voltage (Li-ion)
battery 12V
battery
12V Battery
Key
DANGER
voltage component
Nissan North America, Version (1)
NEVER CUT-High
AAYIA0069GB
DG–33