fuses INFINITI QX60 HYBRID 2015 Dismantling Guide

Page 21 of 49

Powering Down the High Voltage System
The high voltage system can be shut down with any 1 of the following procedures:• Turn OFF the power switch and disconnect the 12-volt battery. Refer to
Primary Procedure
(DG–21)
.
• Remove the underhood fuse for the high voltage control system and disconnect the 12-volt battery. Refer to
Alternate Procedure 1 (Remove Fuses) (DG–23).
• Remove the service plug and disconnect the 12-volt battery. Refer to
Alternate Procedure 2
(Remove Service Plug) (DG–25)
.
Primary Procedure
NOTE: Before disconnecting the 12-volt battery terminal, if necessary, lower the windows, adjust
the steering column, adjust the seats, unlock the doors, etc. Once 12-volt battery is
disconnected, power controls will not operate.
1. If possible, check the READY
indicator status in the instrument cluster. If it is on, the high
voltage system is active.
2. Place the shift selector in the Park (P) position.
3. Push the ignition switch once to turn OFF the high voltage system. Verify that the READY indicator is off
and then continue to the next steps to open the hood
for 12-volt battery negative cable access.
If the READY indicator does not turn off, refer to
Alternate Procedure 1 (Remove Fuses) (DG–23).
4. If possible, keep the Infiniti Intelligent Key at least 5 meters (16 feet) away from the vehicle.
AAYIA0191ZZ
ACC
LOCK
(OFF)
ON
AAYIA0271ZZ
AAYIA0340ZZ
DG–21

Page 23 of 49

Alternate Procedure 1 (Remove Fuses)
NOTE:Before removing any fuses, if necessary, lower the windows, adjust the steering column,
adjust the seats, unlock the doors, etc. Once fuses are removed, power controls will notoperate. 1. Pull release handle (1) and pull up release lever (2) to open the hood.
2. Release clips (A) and remove fuse box cover (1) .
: Vehicle front
3. Remove IGCT RLY fuse (F/L V IGCT RLY 50A) .
4. If you cannot identify the correct fuse, remove all the fuses.
To avoid unintended reinstallation and risk of
electrical shock and severe personal injury or death,
the dismantler should carry the fuse or fuses on his/her
person and cover the fuse box with insulated tape.
1
2
AAYIA0272ZZ
1
A
AAYIA0303ZZ
F/L V IGCT RLY 50A (Red)
AAYIA0071GB
DG–23

Page 29 of 49

13. Disconnect negative (-) battery cable and cover it withinsulated tape.
14. Perform the dismantling operation. Refer to
6. Dismantling Information (DG–39).
3-4.2 Cutting the Vehicle Body
DANGER
•Do not cut into high voltage related areas to avoid severe personal injury or death.

Do not cut into the high voltage battery to avoid severe personal injury or death.

When removing parts, NEVER touch the high voltage parts or the insides of the
exposed orange-colored high voltage cables to avoid severe personal injury or
death. Personal Protective Equipment (PPE) must always be worn when touching or
working on high voltage components.
To avoid unintended reinstallation and risk of electrical shock and severe personal injury or
death, the dismantler should carry the fuses or service plug on his/her person while work
is in progress.
Do not cut air bag parts to avoid unintended deployment of the air bags and the risk of
severe personal injury or death.
If approximately (10) minutes have passed since the rescuer shut down the high voltage system [refer to
3-4.1 High Voltage System Shut-Down Procedure (DG–20)], then the dismantler can cut the vehicle
except for the high voltage battery.
DO NOT cut the high voltage battery due to possible electrocution risk and electrolyte solution leakage.
AAYIA0274ZZ
DG–29