torque INFINITI QX60 HYBRID 2016 Dismantling Guide

Page 12 of 49

No. Component
LocationDescription
Service
Plug Cargo area floor(inside storage bin
behind access door) This is used to disable the high-voltage system.
High-Voltage
Battery Cargo area floor
(under 3rd row
seating floor trim) The high-voltage battery stores and outputs
DC power (Maximum voltage 144V) needed to
propel the vehicle.
Traction Motor Engine compart-
ment (built-into the
transmission) Converts three-phase alternating current (AC)
power to drive power (torque) which propels
the vehicle.
Traction Motor
Inverter Engine compart-
ment (front driver
side) Converts the DC power stored in the high-
voltage battery to three-phase AC power and
controls motor torque (revolution) by regulating
the motor current. The inverter has a built in
high-voltage capacitor.
12-Volt Battery Front of the vehicle
on the left side of
the engine compart-
ment A lead-acid battery that supplies power to the
low voltage devices.
High-Voltage
Harness Cargo area (on
high-voltage bat-
tery) , under floor,
engine compartment Orange-colored power cables carry high DC
voltage between each of the high-voltage
components.
2-3 High-Voltage Battery Pack Specifications High-Voltage Battery Specifications
High-voltage

battery voltage 144V
Number of high-voltage battery modules in the
pack 3 modules (40 cells)
High-voltage battery module voltage 48V each
High-voltage battery dimensions 36.31 x 22.07 x 6.52 in. (922.3 x 560.5 x 165.6 mm)
High-voltage battery weight 62.4 lbs (28.3 kg)
DG–12