traction control INFINITI QX60 HYBRID 2016 Dismantling Guide

Page 12 of 49

No. Component
LocationDescription
Service
Plug Cargo area floor(inside storage bin
behind access door) This is used to disable the high-voltage system.
High-Voltage
Battery Cargo area floor
(under 3rd row
seating floor trim) The high-voltage battery stores and outputs
DC power (Maximum voltage 144V) needed to
propel the vehicle.
Traction Motor Engine compart-
ment (built-into the
transmission) Converts three-phase alternating current (AC)
power to drive power (torque) which propels
the vehicle.
Traction Motor
Inverter Engine compart-
ment (front driver
side) Converts the DC power stored in the high-
voltage battery to three-phase AC power and
controls motor torque (revolution) by regulating
the motor current. The inverter has a built in
high-voltage capacitor.
12-Volt Battery Front of the vehicle
on the left side of
the engine compart-
ment A lead-acid battery that supplies power to the
low voltage devices.
High-Voltage
Harness Cargo area (on
high-voltage bat-
tery) , under floor,
engine compartment Orange-colored power cables carry high DC
voltage between each of the high-voltage
components.
2-3 High-Voltage Battery Pack Specifications High-Voltage Battery Specifications
High-voltage

battery voltage 144V
Number of high-voltage battery modules in the
pack 3 modules (40 cells)
High-voltage battery module voltage 48V each
High-voltage battery dimensions 36.31 x 22.07 x 6.52 in. (922.3 x 560.5 x 165.6 mm)
High-voltage battery weight 62.4 lbs (28.3 kg)
DG–12

Page 14 of 49

2-5 High-Voltage Safety System
The
high-voltage safety system is intended to help keep vehicle occupants and emergency responders safe
from high-voltage electricity. • A high-voltage fuse provides short circuit protection inside the high-voltage battery.
• The high-voltage safety system is insulated from the metal chassis.
• Positive and negative high-voltage power cables are connected to the high-voltage battery and arecontrolled by normally open system main relays (SMR1 and SMR2) . When the vehicle is shut off,
the relays stop electrical flow from leaving the high-voltage battery. However, it can take
approximately ten (10) minutes for the high-voltage capacitor to fully discharge. • The high-voltage system and high-voltage capacitor may remain powered for up to
approximately
10 minutes after the vehicle is shut off. Appropriate Personal Protective
Equipment (PPE) must always be worn when touching or working on high-voltage
components to avoid risk of electrical shock and severe personal injury or death.
• The high-voltage battery retains high-voltage at all times. Appropriate PPE must
always
be worn when touching or working on high-voltage components to avoid risk
of electrical shock and severe personal injury or death.
• A ground fault monitor continuously monitors for high-voltage leakage to the metal chassis while the vehicle is running. If a malfunction is detected, the HPCM (hybrid powertrain control module) will
illuminate the hybrid system warning lamp in the instrument cluster.


The high-voltage battery relays (SMR1 and SMR2) will automatically open to stop the electrical flow
in a front, side or certain rear collisions that are sufficient enough to activate the supplemental
restraint system (SRS) . HPCM
(Hybr

id Powertrain
Control Module) DC/DC
Converter
Service Plug
(With Fuse)
Traction Motor
Inverter
(With built in
High-Voltage capacitor)
Traction
Motor Junction Box
Transmission Engine Compartment
Cargo Area
High-Voltage Battery
System main relay 1
System main relay 2 AAYIA0166GB
DG–14