ECO mode LEXUS GS400 2000 Service Repair Manual

Page 175 of 1111

DI3CO±10
± BODY ELECTRICALTHEFT DETERRENT SYSTEM
BE±141
2442 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)
PRE±CHECK
1. THEFT DETERRENT SYSTEM
When the system is set to the theft deterrent mode and any of
the following conditions are met, the system sounds the horns
and flashes the headlights and the taillights for approx. 1 min-
ute.
At the same time the system locks all doors (If all door are not
locked at once, the system repeats door locking operation ev-
ery 0.55 seconds during the one minute alarm time).
There are 2 modes in this system, which are active mode and
passive mode.
All initial setting are performed in active mode. It can be
switched to passive mode by specified operation. (See step 4.
CHANGING METHOD OF PASSIVE MODE)
Condition:
Any of the doors (Including the engine hood and luggage
compartment door) is unlocked or opened without the
key. *1
The battery terminal is disconnected and reconnected.
The system receives panic signal from remote keyless
entry. *2
*1: Only active arming mode.
*2: When the ignition key is not inserted in the key cylin-
der.
There are 4 conditions in this system which are disarming
condition, disarming preparation condition, arming condition
and alarming condition.
(a) Disarming condition:
(1) When a user is near the vehicle.
(2) When the alarming function does not operate.
(3) When theft deterrent function is not performed.
(b) Disarming preparation condition:
(1) Time from a user locks a door to be leaves the ve-
hicle.
(2) Time until transferring to disarming condition.
(3) Theft deterrent function is not performed.
(c) Arming condition:
(1) When a user leaves the vehicle completely.
(2) When theft deterrent function is possible.

Page 177 of 1111

Disarming condition
Any of the following conditions is met
 When all doors and engine hood are closed, lock all the doors using a key.
 When all doors and engine hood are closed, lock all the doors using wireless remote function.
 When all doors and engine hood are closed, open and close either of doors and engine hood
then close and lock all doors and engine hood.
Disarming preparation condition
Any of the following conditions is met
 30 seconds elapse when the engine hood
is closed and all doors are locked.
Any of the following conditions is met
 Close and open either of all doors and
engine hood.
 Lock and unlock either of doors.
 Insert a key into the ignition key cylinder.
 Reconnect the battery.
Arming condition
Any of the following conditions is met
 Unlock the locked doors using the wireless
remote function.
 Unlock the locked doors using the key.
 Insert the key into the ignition key cylinder
and turn the ignition key ON.
Any of the following conditions is met
 Either of closed doors opens.
 Either of locked doors is unlocked by any
operation other than key or wireless remote
function.
 The closed engine hood is opened.
 The battery is reconnected.
Alarming condition
Any of the following conditions is met
 Unlock the locked doors using the wireless
remote function.
 Unlock the locked doors using the key.
 Insert the key into the ignition key cylinder
and turn the ignition key ON.
In this mode, once theft is detected, it is
informed using light and sound to people
around the vehicle.
The alarming time described above passes.
(Key not inserted in ignition cylinder.)
± BODY ELECTRICALTHEFT DETERRENT SYSTEM
BE±143
2444 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)
2. ACTIVE ARMING MODE

Page 178 of 1111

BE±144
± BODY ELECTRICALTHEFT DETERRENT SYSTEM
2445 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)
Indicator light output:
ConditionIndicator light
Disarming conditionOFF
Arming preparation conditionON
Arming conditionOFF
Alarming conditionON
HINT:
Even in disarming condition, the indicator light flash. (Due to the
signal output form immobilizer system). The indicator always
flashes receiving the signal from the immobilizer system at any
time in the arming condition.
Flashing frequency:
0.75 seconds (ON)
1.25 seconds (OFF)
3. PASSIVE ARMING MODE
This mode can be switched according to the specified op-
eration.
All initially set modes (when shipped from factory) are ac-
tive mode. (No passive mode)

Page 179 of 1111

Disarming condition (A)
Disarming preparation condition
Any of the following
conditions is met
 With all doors and
engine hood closed
30 seconds elapse.
Arming condition
Any of the following conditions is met
(Refer to HINT * on the next page)
 Press unlock switch of the wireless.
 Insert the key into the driver and passenger
doors key cylinders, turn the key to unlock.
 Insert the key into the ignition key cylinder
and turn the key to ON.
Any of the following conditions is met
 Either of closed door is opened and entry
delay time elapses. (Refer to HINT on the
next page)
 Engine hood is closed and opened.
 Battery is reconnected.
Alarming condition
In this mode, once theft is detected, it is
informed using light and sound to people
around the vehicle.
The alarming time described above passes.
Any of the following conditions is met
 Pull the key out of the ignition key cylinder which the key was inserted in.
Disarming condition (B)
Any of the following conditions is met
 Press the unlock button of wireless.
 Insert the key into the key cylinder of driver
or passenger seat and turn the key to unlock.
 Insert the key into the ignition key cylinder.
 Reconnect the battery.
Any of the following conditions is met
 Open and close either of all doors and
engine hood.
Any of the following conditions is
met
 Close and open either of
all doors and engine hood.Any of the following conditions is met
 Press the unlock button of wireless.
 Insert the key into the key cylinder of driver
or passenger seat and turn the key to unlock.
 Insert the key into the ignition key cylinder.
 Reconnect the battery.
Any of the following conditions is met
 Press unlock switch of the wireless.
 Insert the key into the driver and passenger
doors key cylinders, turn the key to unlock.
 Insert the key into the ignition key cylinder
and turn the key to ON.
± BODY ELECTRICALTHEFT DETERRENT SYSTEM
BE±145
2446 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)

Page 180 of 1111

Door
Indicator
Alarming output
System condition
Arming condition Alarming
condition Entry delay time Close
Open
ON
OFF
ON
OFF BE±146
± BODY ELECTRICALTHEFT DETERRENT SYSTEM
2447 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)
HINT:
In arming condition either closed door is opened, entry delay
occurs. (15 secs.)
During this time, the mode transfers to disarming condition
when the condition described above * is met.
When the condition is not met, the system judges theft occurs,
the mode transfers to alarming condition.
(a) Indicator light output:
ConditionIndicator light
Disarming conditionOFF
Arming preparation conditionON
Arming condition
(Entry delay time)OFF
(ON)
Alarming conditionON
HINT:
Even in disarming condition, the indicator light flash. (Due to the
signal output form immobilizer system). The indicator always
flashes receiving the signal from the immobilizer system at any
time in the arming condition.
Flashing frequency:
0.75 seconds (ON)
1.25 seconds (OFF)

Page 181 of 1111

N09348
ECULEXUS hand±held tester
LEXUS Break±out±box
± BODY ELECTRICALTHEFT DETERRENT SYSTEM
BE±147
2448 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)
(b) Transfer to active mode:
In each passive mode, when ºdisarming condition of ac-
tive mode " arming preparation transfer conditionº is
met, the active mode transfers to each condition. In this
case, active mode continues till disarming condition.
Passive mode when transfer condition is
met.Active mode transfer condition
Disarming conditionArming preparation condition
Arming preparation conditionArming preparation condition
Arming condition
(During entry delay time)Arming condition
(After alarming time has elapsed, arming
condition)
Alarming conditionAfter alarming time has elapsed, arming
condition
4. CHANGING METHOD OF PASSIVE MODE (ON or OFF)
Using a hand±held tester, the mode can be changed to the pas-
sive mode.
5. ECU TERMINAL VALUES MEASUREMENT BY USING
LEXUS BREAK±OUT±BOX AND LEXUS HAND±HELD
TESTER
(a) Hook up the LEXUS break±out±box and LEXUS hand±
held tester to the vehicle.
(b) Read the ECU input/ output values by following the
prompts on the tester screen.
(c) Please refer to the LEXUS hand±held tester has a ºSnap-
shotº function. This records the measured data and is ef-
fective in the diagnosis of intermittent problems.

Page 187 of 1111

± BODY ELECTRICALWIRELESS DOOR LOCK CONTROL SYSTEM
BE±153
2454 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)
Replace the transmitter battery with a new or normal
one and check UNLOCK±LOCK function works under
the standard operation.
<Reference>
 The battery should be replaced by only the shops with
sufficient skill as new or normal battery is necessary.
 Battery quality can be judged by checking the rem-
nant volume of the battery.
Ye s
Battery faulty.
No
Make the vehicle be in the initialized condition.
Enter into the self diagnostic mode.
If operating door control receiver in the order of 1 through 2, the mode turns to diagnostic mode.
(1) Insert the key plate in the ignition key cylinder and pull out, then insert it again and turn ignition switch
OFF " ON " OFF once within 5 seconds after pulling out.
(2) After completing the procedure within 30 seconds, turn the ignition switch OFF " ON " OFF 9 times.
HINT:
In the case that either (1) or (2) condition is not satisfied, transfer to normal mode.
<Reference>
When completing self diagnostic mode, turn the ignition switch ON.
LOCK and UNLOCK operation and output of luggage door opener signal are not performed under the self
diagnostic mode.
1st time 9th time ON
OFF
Transmitter battery check:
Inspection start by using self diagnostic mode:
within.
30 sec.within.
5 sec.
123 9
10
Key plate
not inseted
Key plate
inseted
Ignition
switch

Page 188 of 1111

BE±154
± BODY ELECTRICALWIRELESS DOOR LOCK CONTROL SYSTEM
2455 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)
No
No
(Not entered in self
diagnostic mode)Is the method to enter into the
diagnostic mode correct?
Self diagnostic mode operation check:
Ye s
(Entered in self diagnostic mode)
After the self diagnostic mode input operation has
been performed, check that the buzzer chirps.
ON
OFF BuzzerIgnition switch OFF
0.13 sec. 0.5 sec.
Is the chirping function of operation
confirmation buzzer normal?
Check door control buzzer.
Check that continuity exists between
connector terminal A3 of MPX body ECU
on the vehicle side and ground by
inserting the key plate into the ignition
key cylinder. Key unlock warning switch inspection:
Ye s Ye s
No
Check key unlock warning switch.
Self diagnostic mode check:
Check that how the buzzer chirps when pressing
each transmitter switch.
ON
OFF Buzzer
0.13 sec.0.5 sec.
(1) Receiver normal wave of LOCK switch.
ON
OFF Buzzer
0.13 sec.
0.25 sec.
(2) Receiver normal wave of UNLOCK switch.
0.5 sec.
ON
OFF Buzzer
(3) Receiver normal wave of luggage door switch.
0.5 sec.0.5 sec.
ON
OFF (4) Incompatibility of the recognition code or out
from synchronization of rolling code.
While receiving
<Reference>:
While turning the ignition switch ON in the self
diagnostic mode, the mode returns to normal mode. Buzzer
(1), (2) or (3) are output.(4) is output.
(All buzzer's response
is same.)
Recognition code registration function check:
Check that it is possible to enter into
rewrite mode or add mode.
(Refer to ºWireless door lock receiver and
transmitterº ± ºRecognition code registrationº.)
Wireless door lock operates
normally when recognition code
is registered.
No response from buzzer

Page 201 of 1111

BE±162
± BODY ELECTRICALWIRELESS DOOR LOCK CONTROL SYSTEM
2463 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)
2. REPLACE DOOR CONTROL RECEIVER AND TRANS-
MITTER
NOTICE:
When replacing the door control receiver and transmitter,
registration of recongnition code is necessary because
they are provided as single components.
(a) Select which operation mode should be performed from
the following modes.
Add mode
Rewrite mode
Prohibition mode
Confirmation mode
HINT:
The add mode is used to retain codes already registered
while you register new recongnition codes. This mode is
used when adding a transmitter. However, if the number
of registered codes exceeds 4 codes, previously regis-
tered codes are correspondingly erased in order, starting
from the first registered code.
The rewrite mode is used to erase all previously regis-
tered codes and register only new recognition codes.
The prohibition mode is used to erase all registered codes
and cancels the wireless door lock function. Use this
mode when the transmitter is lost.
The confirmation mode is for confirming how many re-
congnition codes are already registered before you regis-
ter additional recognition codes.
(b) Follow the chart on the following pages to register the
transmitter recongnition code at the wireless door lock
conrol receiver.
HINT:
When procedure is out of the specified, the operation re-
turns to normal operation.
Maximum 4 recognition codes can be registered.

Page 203 of 1111

BE±164
± BODY ELECTRICALWIRELESS DOOR LOCK CONTROL SYSTEM
2465 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)
Within
3 secs.
Turn the ignition switch from ON to LOCK at approx. 1 sec. interval 1 to 5 times to select the mode.
Pull out the key plate from the ignition key cylinder.
When add mode or rewrite mode
is selected.When confirmation
mode is selected.
ON
ONON
LOCK
LOCKLOCK
Approx.
1 sec.Approx.
1 sec. Approx. 1 sec.Approx.
1 sec.Approx.
1 sec.
Add mode
Rewrite modeConfirmation mode
ON ± LOCK change occurs 1 time
ON ± LOCK change occurs 2 timesON ± LOCK change occurs 3 times
MPX body ECU automatically performs
the LOCK±UNLOCK operation once
or twice at 1 sec. interval to iniform the
operator that either the add mode or
rewrite mode has been selected.
LOCK±UNLOCK occurs once
LOCK±UNLOCK occurs twice
Indicates that add mode has been selected.
Indicates that rewrite mode has been
selected.
1 sec.
LOCK
1 sec.1 sec.
LOCK
UNLOCK
UNLOCK
LOCK
2 secs.2 secs.
UNLOCK MPX body ECU automatically performs the
LOCK±UNLOCK operation 1 to 4 times at
2 sec. interval to inform the operator of
the number of the registered codes.
HINT:
When the number of the registered code
is 0, the operation is automatically
performed 5 times.
Example:
When the operation is performed twice, it
directs that 2 types of recognition code
have been registered.
1st time 2nd time
Registration of recognition code (Confirmation
mode and prohibition mode) is completed.
ON
LOCK
Approx.
1 sec.Approx.
1 sec.
Prohibition mode
ON ± LOCK change occurs 5 times
When prohibition
mode is selected.

Page:   1-10 11-20 21-30 next >