radiator MITSUBISHI LANCER EVOLUTION VI 1999 User Guide
Page 293 of 558
EXTERIOR – Intercooler & Radiator Water Spray System51-7
INTERCOOLER & RADIATOR WATER SPRAY SYSTEM
REMOVAL AND INSTALLATION
Pre-removal and Post-installation Operations
Front Bumper Removal and Installation (Refer to P.51-2)
2
13
5 4
68
7 9
10
2.5 Nm
2.5 Nm
4
54
4 5
5
6 4
4
4
2
15
6
5
4
2
1754 4 3
2 1
5
1. Clamp
2. Water spray nozzle
3. Water spray nozzle bracket
A4. Water spray hose
5. Joint
6. Stop valve
A7. ClipWater spray motor removal steps
8. Water spray tank
9. Water spray hose
10. Water spray tank
NOTE
(1) The installation service points for the new model are the
same as those for preceding models.
(2) The water spray switch can be serviced in the same
procedure as for the preceding models.
Page 374 of 558
CHASSIS ELECTRICAL – HeadlampCHASSIS ELECTRICAL – Headlamp54-36
4. After the bulb is replaced, reinstall the socket cover with
the TOP mark facing upward.
NOTE
To prevent the clouding of lens and ingress of water into
the lamp unit, install the socket cover correctly.
POSITION LAMP BULB REPLACEMENT
Remove the position lamp by turning it together with the lamp
socket, then replace its bulb.
HEADLAMP AND FRONT TURN-SIGNAL LAMP
REMOVAL AND INSTALLATION
CAUTION: SRS
Before removal of air bag module and clock spring, refer to GROUP 52B – SRS Service Precautions and Air
Bag Module and Clock Spring.
5 Nm
2 3
4
5 Nm
1
1. Column switchRemoval steps
A2. Front turn-signal lamp
3. Radiator grille
A4. Headlamp
Position lamp connector
Page 394 of 558
HEATER AND MANUAL AIR CONDITIONER – Troubleshooting55-4
TROUBLESHOOTING
TROUBLESHOOTING PROCEDURES
1. Check air ducts, control rods, etc. for improper connection.
2. Check that the electrical connectors of the relevant components are connected securely and the
fuse is not blown.
3. Perform the troubleshooting as follows; first understand the items to be inspected and the the procedures
comprehensively using Trouble Symptom/Failed Component Cross-Reference Table and then inspect
the appropriate items sequentially.
4. Be sure to perform each component check after disconnecting the relevant connector.
Trouble Symptom/Failed Component Cross-Reference Table
Items to be checked1.
When the igni-
tion switch is
“ON”, the A/C
does not oper-
ate.2.
When the A/C
is operating,
temperature
inside the pas-
senger
compartment
does not
decrease (cool
air is not
emitted).3.
Blower fan
motor does not
turn.4.
Blower fan
motor does not
stop turning.5.
When A/C is
operating,
radiator fan
and condenser
fan do not run.
Fuse111
Harness, connector2212
Amount of refrigerant31
A/C compressor relay4
A/C compressor magnet
clutch5
Dual pressure switch623
A/C switch7
Blower switch832
Blower relay4
Resistor53
Blower motor6
Air thermo-sensor93
Condenser fan relay44
Condenser fan motor55
Radiator fan relay (HI, LO)66
Radiator fan motor77
Refrigerant temperature
switch108
Auto compressor control
unit119
Engine-ECU12108
Page 395 of 558
HEATER AND MANUAL AIR CONDITIONER – Troubleshooting55-5
No.Trouble symp-
tomProblem causeRemedyRefer-
ence
page
1When the igni-
tion switch is
“ON”, the A/C
does not oper
Refrigerant leak or overfilling of refriger-
antReplenish the refrigerant, repair the
leak or take out some of the
refrigerant55-6
does not oper-
ate.A/C compressor relay is defectiveReplace the A/C compressor relay55-14ate.
A/C compressor magnetic clutch is
defectiveReplace the A/C compressor magnet
clutch55-26
Dual pressure switch is defectiveReplace the dual pressure switch55-13
A/C switch is defectiveReplace the A/C switch55-17
Blower switch is defectiveReplace the blower switch55-17
Air thermo-sensor is defectiveReplace the air thermo-sensor55-22
Refrigerant temperature switch is defec-
tiveReplace the refrigerant temperature
switch55-25
Automatic compressor-ECU is defectiveReplace the automatic compressor-
ECU–
2When the A/C is
operating, tem-
perat re inside
Refrigerant leakReplenish the refrigerant and repair
the leak55-6
perature inside
the
passengerDual pressure switch is defectiveReplace the dual pressure switch55-13the passenger
compartment
doesn’tde-Air thermo-sensor is defectiveReplace the air thermo-sensor–doesnt de-
crease (cool air
is not emitted)
Condenser fan relay is defectiveReplace the condenser fan relay55-14
is not emitted).Condenser fan motor is defectiveReplace the condenser fan motor55-29
Radiator fan relay (HI, LO) is defectiveReplace the radiator fan relay (HI, LO)55-14
Radiator fan motor is defectiveReplace the radiator fan motor–
Refrigerant temperature switch is defec-
tiveReplace the refrigerant temperature
switch55-25
Automatic compressor-ECU is defectiveReplace the automatic compressor-
ECU–
3Blower fan mo-
tor doesn’t turn
Blower switch is defectiveReplace the blower switch55-17
tor doesn’t turn.Blower relay is defectiveReplace the blower relay55-13
Resistor is defectiveReplace the resistor55-21
Blower fan motor is defectiveReplace the blower fan motor55-21
4Blower fan mo-
tor doesn’t stop
t rning
Defective harness between the blower
fan motor and the blower switchRepair the harness–
turning.Blower switch is defectiveReplace the blower switch55-17
Resistor is defectiveReplace the resistor55-21
5When the A/C is
operating con
Condenser fan relay is defectiveReplace the condenser fan relay55-14
operating con-
denser fan orCondenser fan motor is defectiveReplace the condenser fan motor55-29denser an or
radiator fan
does not runRadiator fan relay (HI, LO) is defectiveReplace the radiator fan relay (HI, LO)55-14does not run.
Radiator fan motor is defectiveReplace the radiator fan motor–
Dual pressure switch is defectiveReplace the dual pressure switch55-13
Engine-ECU is defectiveReplace the engine-ECU–
Page 404 of 558
HEATER AND MANUAL AIR CONDITIONER – On-vehicle Service55-14
A/C COMPRESSOR RELAY, CONDENSER FAN RELAY
Battery voltageTerminal No.
1345
Power is not supplied
Power is supplied
IDLE-UP OPERATION CHECK
1. Before inspection and adjustment, set vehicle in the
pre-inspection condition:
2. Check whether or not the idle speed is the standard value.
Standard value: 700 ± 50 r/min
NOTE
There is no necessity to make an adjustment, because
the idle speed is automatically adjusted by the ISC system.
If, however, there occurs a deviation from the standard
value for some reason, check the fuel control system.
3. When the A/C is running after turning the A/C switch
to ON, check to be sure that the idle speed is at the
standard value.
Standard value: 850 ± 50 r/min
Fan control relay
Compressor
relay
Radiator
fan relay
Condenser
fan relay
Page 418 of 558
– Condenser and Condenser Fan HEATER AND MANUAL
AIR CONDITIONER55-28
CONDENSER AND CONDENSER FAN
REMOVAL AND INSTALLATION
12 Nm
46
2
1 5
37
8
Piping connection
O-ring
A/C Compressor oil: SUN PAG 56
Condenser fan removal steps
Front bumper
A1. Condenser fan motor and shroud
assembly
2. Fan
3. Motor assembly
4. ShroudCondenser removal steps
Discharging and charging of
refrigerant (Refer to P.55-6.)
5. Reserve tank
6. Radiator mounting bolt
B7. Discharge hose, liquid pipe A
connection
C8. Condenser
Page 419 of 558
– Condenser and Condenser Fan HEATER AND MANUAL
AIR CONDITIONER55-29
REMOVAL SERVICE POINTS
AFAN MOTOR AND SHROUD ASSEMBLY
REMOVAL
Remove the clamp bolt of the power steering oil cooler pipe.
Remove the fan motor and shroud assembly while pulling
the power steering oil cooler pipe toward you.
BDISCHARGE HOSE / LIQUID PIPE A
DISCONNECTION
Plug the open end of the disconnected hose and the opening
in the cooling unit not to let foreign matter get into them.
Caution
Seal the hoses completely, otherwise the compressor
oil and receiver will absorb water vapour easily.
CCONDENSER REMOVAL
Move the radiator to the engine side and then lift up the
condenser to remove it.
INSPECTION
CONDENSER FAN MOTOR CHECK
Battery connection terminalCondenser fan operation
12
Rotate
Condenser
Page 441 of 558
FULL-AUTOMATIC AIR CONDITIONER – Troubleshooting55-51
NG
Repair OK
Check the trouble symptom.
NG
Repair
OK
Check the trouble symptom.
NG
Check the harness between the condenser fan motor relay (HI)
and the engine-ECU, and repair if necessary.
Measure at the radiator fan motor relay (HI) connector A-114X.
Disconnect the connector.
(1) Continuity between 4-B-59 and connector terminal (20)
OK:Continuity
(2) Voltage between terminal (2) and body earth (Ignition
switch: ON)
OK:System voltage
(3) Voltage between terminal (1) and body earth
OK:System voltage(1) NGCheck the following connectors:
A-114X, A-28, B-59
From the previous page
NG
Repair
OK
Check the trouble symptom.
NG
Check the harness between the condenser fan motor relay (HI)
and the ignition switch, and repair if necessary.
(2) NG
Check the following connector:
A-114X
NG
Repair
OK
Check the trouble symptom.
NG
Check the harness between the condenser fan motor relay (HI)
and the fusible link 2, and repair if necessary.
(3) NG
Check the following connector:
A-114X
OK
Measure at the condenser fan motor connector A-99.
Disconnect the connector, and measure at the harness
side connector.
Connect the terminal B-59 to the earth.
Voltage between terminal (1) and body earth (Ignition switch:
ON)
OK:System voltageNOCheck the following connector:
A-112X
NG
Check the harness between the condenser fan motor relay (HI)
and the condenser fan motor, and repair if necessary.
Inspection procedure 14
Rear defogger does not operate.
Probable cause
If the rear defogger does not operate when the rear defogger switch is turned
on (timer operates for 20 minutes), the cause is probably a malfunction of the
A/C-ECU power supply system (earth).Malfunction of connector or harness
Malfunction of A/C-ECU
Can an operating sound be heard when the rear defogger switch
is operated?NOInspection procedure 15 (Refer to P.55-52.)
YES
Replace the A/C-ECU.
Page 452 of 558
FULL-AUTOMATIC AIR CONDITIONER –
Outside Air Temperature
Sensor55-62
OUTSIDE AIR TEMPERATURE SENSOR
REMOVAL AND INSTALLATION
Pre-removal and Post-installation Operation
Radiator Grille Removal and Installation
Outside air temperature sensor
INSPECTION
When the resistance value between the sensor terminals is
measured under two or more temperature conditions, the
resistance value should be close to the values shown in the
graph.
NOTE
The temperature conditions when testing should not exceed
the range of the characteristic curve in the graph.Resistance kΩ
Temperature C 20
15
10
0 5
–10 0 4020 30 10
Page 454 of 558
FULL-AUTOMATIC AIR CONDITIONER –
Heater Water Temperature Sensor /
Other Maintenance Service Points55-64
INSPECTION
Follow the same procedure as for the inspection of the outside
temperature sensor. (Refer to P55-62.)
OTHER MAINTENANCE SERVICE POINTS
The following maintenance service points are the same as for the manual A/C.
ItemsReference page
Dual Pressure Switch55-13
Blower Relay, A/C Compressor Relay, Condenser Fan Relay, Radiator Fan Relay55-13, 14
Idle-up System55-14
Heater Unit, Cooling and Blower Unit55-15
Blower Motor Assembly, Evaporator55-19
Compressor, Tension Pulley55-23
Condenser, Condenser Fan55-28
Ducts55-31