MITSUBISHI MONTERO 2003 Service Repair Manual

Page 811 of 1000

ACX00915
3Checking of Parts Associated with
Probable Causes and Determination
of Faulty Parts 2
Determination of Probable Causes
4Repair and Confirmation
Observe the symptom carefully. Check if there are also
other problems.
In determining the probable causes, it is necessary to
study the wiring diagram to understand the circuit as a
system. Knowledge of switches, relays and other parts is
necessary for accurate analysis. The causes of similar
problems in the past must be taken into account.
Troubleshooting is carried out by making step-by-step
checks until the cause is found.
After the problems are corrected, be sure to check that the
system operates correctly. Also check that new problems
have not been caused by the repair.
AC
1
Observation of Problem Symptoms

Page 812 of 1000

ACX00936AB
CLICK
ACX00937
ACX00938
ABSELECTOR KNOBPOINTER

Page 813 of 1000

CAUTION
CAUTION
ACX00939
ACX00940
ACX00941
ACX00942
AB
RED LEAD WIREPOWER LINE
BLACK LEAD WIRE
GROUND

Page 814 of 1000

ACX00943
ACX00944 AB
CURRENT
FLOWSCURRENT DOES
NOT FLOW CURRENT DOES
NOT FLOWCURRENT FLOWS OFF
OFFON
ON NORMAL OPEN (NO) TYPE
NORMAL CLOSED (NC) TYPE

Page 815 of 1000

ACX00945 AB
6
OFF
5
432
1
1ST 2ND 3RD
4THSTAGE
ACX00947
AB
COVER
SPRING
IRON
CORE
COIL
IRON
PIECE
CONTACT
ACX00948
AB
POWER SUPPLY
FUSE
LIGHTRELAY
SWITCH
ON
OFFON
OFF

Page 816 of 1000

ACX00949AB
NORMAL OPEN (NO) TYPE
DEENERGIZED STATE ENERGIZED STATE
CURRENT FLOWS CURRENT DOES
NOT FLOW
ACX00950AB
NORMAL CLOSED (NC) TYPE
DEENERGIZED STATE
ENERGIZED STATE
CURRENT FLOWSCURRENT DOES
NOT FLOW
ACX00951
AB
FUSE BLOCK
TEST TAPS
ACX00952
AB
STATE OF FUSE BLOWN DUE TO
OVERCURRENT

Page 817 of 1000

WARNING
ACX00953AB
STATE OF FUSE BLOWN DUE TO
THERMAL FATIGUE
ACX00954AB
ACX00955
AB
AC000017

Page 818 of 1000

ACX00956 AB
POWER SUPPLY
FUSE
SWITCH
MOTOR (3) ON (2)
OFF
(1)TEST LIGHT
(OR
VOLTMETER)
ACX00957
AB
POWER SUPPLY
SWITCH
OFF
ILLUMINATION
LIGHT TEST
LIGHTFUSE BLOCK
(REMOVE
THE FUSE)
SHORT-CIRCUIT
LOCATION

Page 819 of 1000

ACX00958
AB
POWER SUPPLY
SWITCH
ON
ILLUMINATION
LIGHT TEST
LIGHTFUSE BLOCK
(REMOVE
THE FUSE)
DISCONNECT
THE LOAD
SHORT-CIRCUIT
LOCATION
ACX00959
AB
POWER SUPPLY
SWITCH
ON
ILLUMINATION
LIGHT TEST
LIGHTFUSE BLOCK
(REMOVE
THE FUSE)
DISCONNECT
THE LOAD
SHORT-CIRCUIT
LOCATION

Page 820 of 1000

ACX00960AB
SELF POWER TEST
LIGHT (OR OHMMETER)14
23
ON
OFF ON
OFF

Page:   < prev 1-10 ... 771-780 781-790 791-800 801-810 811-820 821-830 831-840 841-850 851-860 ... 1000 next >