NISSAN LATIO 2009 Service Repair Manual
Page 1561 of 4331
EC
NP
O
1. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-III.
2. Start engine and warm it up to normal operating temperature.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
5. Let engine idle for 1 minute.
6. Make sure that “COOLAN TEMP/S” indicates more than 70 °C (158 °F).
If not, warm up engine and go to next step w hen “COOLAN TEMP/S” indication reaches 70 °C (158 °F).
7. Open engine hood.
8. Select “HO2S2 (B1) P1147” of “HO2S2” in “DTC WORK SUPPORT” mode with CONSULT-III.
9. Follow the instruction of CONSULT-III. NOTE:
It will take at most 10 minutes until “COMPLETED” is displayed.
10. Touch “SELF-DIAG RESULT”.
Which is displayed on CONSULT-III screen? OK >> INSPECTION END
NG >> Go to EC-207, " Diagnosis Procedure " .
CAN NOT BE DIAGNOSED>>GO TO 4. Component Function Check " .
NOTE:
Use component function check to check the overall function of the heated oxygen sensor 2 circuit. During this
check, a 1st trip DTC might not be confirmed.
Is the inspection result normal? YES >> INSPECTION END
NO >> Go to EC-207, " Diagnosis Procedure " .
Component Function Check INFOID:0000000004780122YES >> INSPECTION END
NO >> GO TO 2.
Page 1562 of 4331
YES >> INSPECTION END
NO >> GO TO 3. YES >> INSPECTION END
NO >> Go to EC-207, " Diagnosis Procedure " .
ECM
Ground Condition Voltage
Con-
nector Terminal
F11 50
(HO2S2 signal) Ground
Keeping engine speed
at idle for 10 minutes The voltage should be
above 0.68 V at least once
during this procedure.
Page 1563 of 4331
EC
NP
O
Wiring Diagram
INFOID:0000000004780682
Diagnosis Procedure INFOID:0000000004780123Ground Inspection " .
Is the inspection result normal?
Page 1564 of 4331
MIXTURE RATIO SELF-LEARNING VALUE
CLEAR : Special Repair Requirement " .
2. Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0171 detected? Is it difficult to start engine?YES >> Perform trouble diagnosis for DTC P0171. Refer to
EC-229, " DTC Logic " .
NO >> GO TO 3. YES >> GO TO 4.
NO >> Repair open circuit or short to ground or short to power in harness or connectors. YES >> GO TO 5.
NO >> Repair open circuit or short to ground or short to power in harness or connectors. Component Inspection " .
Is the inspection result normal? YES >> GO TO 7.
NO >> GO TO 6. HO2S2 ECM
Continuity
Connector Terminal Connector Terminal
F13 4 F11 50 Existed
HO2S2 Ground Continuity
Connector Terminal
F13 4 Ground Not existed
ECM Ground Continuity
Connector Terminal
F11 50 Ground Not existed
Page 1565 of 4331
EC
NP
O
Replace heated oxygen sensor 2.
CAUTION:
• Discard any sensor which has been dropped from a he ight of more than 0.5 m (19.7 in) onto a hard
surface such as a concrete floor; use a new one.
• Before installing new sensor, clean exhaust syst em threads using Oxygen Sensor Thread Cleaner
[commercial service tool (J-43897-18 or J43897-12)] and approved Anti-seize Lubricant (commercial
service tool).
>> INSPECTION END Diagnosis Procedure " .
>> INSPECTION END
Component Inspection INFOID:0000000004780124YES >> GO TO 2.
NO >> GO TO 3. YES >> INSPECTION END
NO >> GO TO 6.
Page 1566 of 4331
EC-210< COMPONENT DIAGNOSIS >
[HR16DE]
P0137 HO2S2
5. Check the voltage between ECM harness connector and ground under the following condition.
Is the inspection result normal? YES >> INSPECTION END
NO >> GO TO 4. 4.
CHECK HEATED OXYGEN SENSOR 2-II
Check the voltage between ECM harness connector and ground
under the following condition.
Is the inspection result normal? YES >> INSPECTION END
NO >> GO TO 5. 5.
CHECK HEATED OXYGEN SENSOR 2-III
Check the voltage between ECM harness connector and ground
under the following condition.
Is the inspection result normal? YES >> INSPECTION END
NO >> GO TO 6. 6.
REPLACE HEATED OXYGEN SENSOR 2
Replace heated oxygen sensor 2.
CAUTION:
• Discard any sensor which has been dropped from a he ight of more than 0.5 m (19.7 in) onto a hard
surface such as a concrete floor; use a new one. ECM
Ground Condition Voltage
Con-
nector Termi-
nal
F11 50
(HO2S2 signal) Ground Revving up to 4,000
rpm under no load at
least 10 times The voltage should be
above 0.68 V at least once
during this procedure.
The voltage should be be-
low 0.18 V at least once
during this procedure. PBIB2996E
ECM
Ground Condition Voltage
Con-
nector Termi-
nal
F11 50
(HO2S2 signal) Ground
Keeping engine speed
at idle for 10 minutes The voltage should be
above 0.68 V at least once
during this procedure.
The voltage should be be-
low 0.18 V at least once
during this procedure. JMBIA2199ZZ
ECM
Ground Condition Voltage
Con-
nector Termi-
nal
F11 50
(HO2S2 signal) Ground Coasting from 80 km/h
(50 MPH) in D position
(A/T), 4th gear position
(M/T) The voltage should be
above 0.68 V at least once
during this procedure.
The voltage should be be-
low 0.18 V at least once
during this procedure. JMBIA2200ZZ
Page 1567 of 4331
EC
NP
O
• Before installing new sensor, clean exhaust syst
em threads using Oxygen Sensor Thread Cleaner
[commercial service tool (J-43897-18 or J43897-12)] and approved Anti-seize Lubricant (commercial
service tool).
>> INSPECTION END
Page 1568 of 4331
EC-212< COMPONENT DIAGNOSIS >
[HR16DE]
P0138 HO2S2
P0138 HO2S2
Description INFOID:0000000004780125
The heated oxygen sensor 2, after three way catalyst (manifold),
monitors the oxygen level in the exhaust gas on each bank.
Even if switching characteristics of the air fuel ratio (A/F) sensor 1
are shifted, the air-fuel ratio is cont rolled to stoichiometric, by the sig-
nal from the heated oxygen sensor 2.
This sensor is made of ceramic zirconia. The zirconia generates volt-
age from approximately 1 V in richer conditions to 0 V in leaner con-
ditions.
Under normal conditions the heated ox ygen sensor 2 is not used for
engine control operation.
DTC Logic INFOID:0000000004780126
DTC DETECTION LOGIC
The heated oxygen sensor 2 has a much longer switching time between rich and lean than the air fuel ratio (A/
F) sensor 1. The oxygen storage capa city of the three way catalyst (manifold) causes the longer switching
time.
MALFUNCTION A
To judge the malfunctions of heated oxygen sensor 2, ECM monitors
whether the voltage is unusually high during the various driving con-
dition such as fuel-cut.
MALFUNCTION B
To judge the malfunctions of heated oxygen sensor 2, ECM monitors
whether the minimum voltage of sensor is sufficiently low during the
various driving condition such as fuel-cut. SEF327R
PBIB1848E
PBIB2376E
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0138 Heated oxygen sensor 2
circuit high voltage A)
An excessively high voltage from the
sensor is sent to ECM. • Harness or connectors
(The sensor circuit is open or shorted)
• Heated oxygen sensor 2
B) The minimum voltage from the sensor is
not reached to the specified voltage. • Harness or connectors
(The sensor circuit is open or shorted)
• Heated oxygen sensor 2
• Fuel pressure
• Fuel injector
Page 1569 of 4331
EC
NP
O
DTC CONFIRMATION PROCEDURE
YES >> Go to
EC-215, " Diagnosis Procedure " .
NO-1 >> With CONSULT-III: GO TO 3.
NO-2 >> Without CONSULT-III: GO TO 5. OK >> INSPECTION END
NG >> Go to EC-215, " Diagnosis Procedure " .
CAN NOT BE DIAGNOSED>>GO TO 4. Diagnosis Procedure " .
NOTE:
Use component function check to check the overall function of the heated oxygen sensor 2 circuit. During this
check, a 1st trip DTC might not be confirmed.
Is the inspection result normal? YES >> INSPECTION END
NO >> Go to EC-215, " Diagnosis Procedure " .
Component Function Check INFOID:0000000004780127
Page 1570 of 4331
EC-214< COMPONENT DIAGNOSIS >
[HR16DE]
P0138 HO2S2
Without CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
4. Let engine idle for 1 minute.
5. Check the voltage between ECM harness connector and ground under the following condition.
Is the inspection result normal? YES >> INSPECTION END
NO >> GO TO 2. 2.
PERFORM COMPONENT FUNCTION CHECK-II
Check the voltage between ECM harness connector and ground
under the following condition.
Is the inspection result normal? YES >> INSPECTION END
NO >> GO TO 3. 3.
PERFORM COMPONENT FUNCTION CHECK-III
Check the voltage between ECM harness connector and ground
under the following condition.
Is the inspection result normal? YES >> INSPECTION END
NO >> Go to EC-215, " Diagnosis Procedure " .
ECM
Ground Condition Voltage
Con-
nector Termi-
nal
F11 50
(HO2S2
signal) Ground
Revving up to 4,000
rpm under no load at
least 10 times The voltage should be
above 0.18 V at least once
during this procedure. PBIB2996E
ECM
Ground Condition Voltage
Con-
nector Termi-
nal
F11 50
(HO2S2
signal) Ground
Keeping engine speed
at idle for 10 minutes The voltage should be above
0.18 V at least once during
this procedure. JMBIA2199ZZ
ECM
Ground Condition Voltage
Con-
nector Termi-
nal
F11 50
(HO2S2 signal) GroundCoasting from 80 km/h
(50 MPH) in D position
(A/T), 4th gear position
(M/T) The voltage should be
above 0.18 V at least once
during this procedure. JMBIA2200ZZ