harness NISSAN LEAF 2017 1.G Dismantling Guide
Page 44 of 48
4. Disconnect the cabin heater harness connector (A) from
the high-voltage battery. Touching high-voltage components without wearing
appropriate
Personal Protective Equipment (PPE) will
cause electrocution.
a. Use the following instructions to disconnect thecabin heater harness connector. To prevent electrocution, cover battery side of high-
voltage
connector with insulated tape. : Insulated tape
5.
Disconnect the high-voltage battery vehicle
communications connector (A) while turning it
counterclockwise. Touching high-voltage components without wearing
appropriate
Personal Protective Equipment (PPE) will
cause electrocution.
A
AAYIA0171ZZ 1
3 4
2
Pull back lock tab
Press release and
pull connector
Disconnect connector
AAYIA0050GB AAYIA0172ZZ
A
AAYIA0167ZZ
DG–44