fuse PEUGEOT BOXER 2015 User Guide

Page 149 of 276

147
door pillar, right-hand side, fuses
unclip the cover
When you have finished, close the cover
carefully
. Fuses
A (amps) Allocation
54 -Not used
55 15Heated seats
56 15Rear passenger 12 V socket
57 10
under seat additional heating
58 15Heated rear screen, left-hand
59 15Heated rear screen, right-hand
60 -Not used
61 -Not used
62 -Not used
63 10Rear passenger additional control
64 -Not used
65 30Rear passenger additional heating fan
QuICK HeLP
8
Failed fuse

Page 150 of 276

148
Fuses in the engine compartment
Remove the nuts and tilt the box to access
the fuses.
refit the cover carefully after checking or

replacing fuses. Fuses
A (amps) Allocation
1 40ABS pump supply
2 50Diesel pre-heat unit
3 30Ignition switch - Starter motor
4 40Fuel heater
5 20/50Cabin ventilation with additional programmable heating
(battery +)
6 40/60Cabin fan maximum speed (battery +)
7 40/50/60 Cabin fan minimum speed (battery +)
8 40Cabin fan assembly (ignition switch +)
9 15Rear 12 V socket (battery +)
10 15Horn
11 -Not used
14 15Front 12 V socket (battery +)
15 15Cigarette lighter (battery +)
16 -Not used
17 -Not used
18 7.5
engine management control unit (battery +)
19 7.5Air conditioning compressor
20 30Screenwash/headlamp wash pump
21 15Fuel pump supply
22 -Not used
23 30ABS electrovalves
24 7.5Auxiliary switch panel - Door mirror controls and folding


(ignition switch +)
30 15Door mirror heating
Failed fuse

Page 269 of 276

267
SymptomElectricalHydraulic Verification / check
the unit operates but


does not generate
pressure. X
Valve slider jammed if no electrovalve on the unit.
Refer to the "Servicing" section.
X Pressure relief, adjustment, cleanliness.
X Pump seal failed.
X Motor / pump coupling.
X Pump loose on its bracket.
the hydraulic unit does


not operate. X
electrovalve jammed, replace it or tighten the nut behind the strainer

.
the control unit does


not operate. X
Check the connections and contacts.
emulsion in the


reservoir. X
Return pipe incorrectly fitted.
X Fluid level to low.
Fluid discharged from
the breather. X
too much fluid.
X Breather diaphragm tolerance a little wide, to be replaced.
Only valid for
uD2386 units.
the fuse blows when


going down. X
Replace the return valve winding.
SPeCIAL FeAtuReS
tipper body