Ram 1500 2015 Diesel Supplement
Page 211 of 347
NOTE:If the ignition switch is left in the ACC or RUN
(engine not running) position and the transmission is in
PARK, the system will automatically time out after 30
minutes of inactivity and the ignition will switch to the
OFF position.
ENGINE START/STOP Button Functions — With
Driver ’s Foot OFF The Brake Pedal (In PARK Or
NEUTRAL Position)
The ENGINE START/STOP button operates similar to an
ignition switch. It has three positions, OFF, ACC, RUN.
To change the ignition switch positions without starting
the vehicle and use the accessories follow these steps:
1. Starting with the ignition in the OFF position:
2. Press the ENGINE START/STOP button once to change the ignition to the ACC position. 3. Press the ENGINE START/STOP button a second time
to change the ignition to the RUN position.
4. Press the ENGINE START/STOP button a third time to return the ignition to the OFF position.
Keyless Enter-N-Go™ Starting Procedure —
Engine Manifold Air Temperature 0° F To 66° F
(–18° C to 19° C)
NOTE: The temperature displayed in the Electronic
Vehicle Information Center (EVIC) or Driver information
Display (DID) does not necessarily reflect the engine
manifold air temperature. Refer to “Electronic Vehicle
Information Center (EVIC)” or Driver Information Dis-
play (DID)” in “Understanding Your Instrument Panel”
for further information. When engine temperatures fall
below 66°F (19°C) the “Wait To Start Light” will remain
on indicating the intake manifold heater system is active.
4
STARTING AND OPERATING 209
Page 212 of 347
Follow the steps in the “Normal Starting” procedure
except:
1. Pushing the engine start button with the driver ’s footon the brake will move the ignition from OFF or ACC
to RUN, and will illuminate the Wait To Starttelltale.
The engine will not immediately crank, this is normal
operation.
2. The “Wait To Start telltale will remain on for a period
of time that varies depending on the engine tempera-
ture.
3. While the Wait to Start telltale is on, the EVIC/DID
will additionally display a gauge or bar whose initial
length represents the full Wait to Starttime period.
Its length will decrease until it disappears when the
Wait to Start time has elapsed.CAUTION!
If the “Water in Fuel Indicator Light” remains on, DO
NOT START engine before you drain the water from
the fuel filters to avoid engine damage. Refer to
“Maintenance Procedures/Draining Fuel/Water Sepa-
rator Filter” in “Maintaining Your Vehicle” for fur-
ther information.
4. After the engine “Wait To Start” telltale goes off, the engine will automatically crank.
CAUTION!
The engine may automatically crank when the “Wait
To Start” time has elapsed. To abort the automatic
starting process, ensure the driver ’s foot is fully
removed from the brake pedal prior to pushing the
START/STOP button to cycle the ignition off.
210 STARTING AND OPERATING
Page 213 of 347
5. After engine start-up, check to see that there is oilpressure.
6. Allow the engine to idle about three minutes until the manifold heaters have completed the post-heat cycle.
7. Release the parking brake and drive.
NOTE:
• Engine idle speed will automatically increase to 1,000
RPM and engage the Variable Geometry Turbocharger
at low coolant temperatures to improve engine warm-
up.
• The engine may not automatically crank after the
engine Wait To Start telltale goes off if a door or the
hood is ajar.
• If the engine stalls, or if the ignition switch is left ON
for more than two minutes after the “Wait To Start
Light” goes out, reset the grid heaters by turning the ignition switch to the OFF position for at least five
seconds and then back ON. Repeat steps 1 through 7 of
“Keyless Enter-N-Go™ Starting Procedure – Engine
Manifold Air Temperature Below 66° F (19° C).”
Extreme Cold Weather
The Cummins® diesel engine is equipped with several
features designed to assist cold weather starting and
operation:
•
The engine block heater is a resistance heater installed
in the water jacket of the engine just above and behind
the oil filter. It requires a 110–115 Volt AC electrical
outlet with a grounded, three-wire extension cord.
NOTE: The engine block heater cord is a factory installed
option. If your vehicle is not equipped, heater cords are
available from your authorized MOPAR® dealer.
4
STARTING AND OPERATING 211
Page 214 of 347
•A 12 Volt heater built into the fuel filter housings aid in
preventing fuel gelling. It is controlled by a built-in
thermostat.
• A heated intake air system both improves engine
starting and reduces the amount of white smoke
generated by a warming engine.
Normal Starting Procedure — Engine Manifold Air
Temperature Above 66° F (19° C)
Observe the instrument panel cluster lights when starting
the engine.
1. Always apply the parking brake.
2. Shift into PARK for an automatic transmission. For vehicles equipped with a manual transmission, fully
press and hold the clutch pedal and shift into NEU-
TRAL. 3. Turn the ignition switch to the ON position and watch
the instrument panel cluster lights.
CAUTION!
If the “Water in Fuel Indicator Light” remains on, DO
NOT START the engine before you drain the water
from the fuel filters to avoid engine damage. Refer to
“Maintenance Procedures/Draining Fuel/Water Sepa-
rator Filter” in “Maintaining Your Vehicle” for fur-
ther information.
4. Turn the ignition switch to the START position and crank the engine. Do not press the accelerator during
starting.
212 STARTING AND OPERATING
Page 215 of 347
CAUTION!
Do not crank engine for more than 15 seconds at a
time or starter motor damage may result. Turn the
ignition switch to the OFF position and wait at least
two minutes for the starter to cool before repeating
start procedure.
5. When the engine starts, release the key fob.
6. Check that the oil pressure warning light has turned off.
7. Release the parking brake.
Starting Procedure — Engine Manifold Air
Temperature 0°F To 66°F (–18°C to 19°C)
NOTE: The temperature displayed in the Electronic
Vehicle Information Center (EVIC) or Driver Information
Display (DID) does not necessarily reflect the engine
manifold air temperature. Refer to “Electronic Vehicle
Information Center (EVIC)” or “Driver Information Dis-
play (DID)” in “Understanding Your Instrument Panel”
for further information. When engine temperatures fall
below 66°F (19°C) the “Wait To Start Light” will remain
on indicating the intake manifold heater system is active.
Follow the steps in the “Normal Starting” procedure
except:
1. The “Wait To Start” telltale will remain on for a period of time that varies depending on the engine tempera-
ture.
4
STARTING AND OPERATING 213
Page 216 of 347
2. While theWait To Start” telltale is on, the EVIC/DID
will additionally display a gauge or bar whose initial
length represents the full Wait To Starttime period.
Its length will decrease until it disappears when the
Wait To Start time has elapsed.
CAUTION!
If the “Water in Fuel Indicator Light” remains on, DO
NOT START engine before you drain the water from
the fuel filters to avoid engine damage. Refer to
“Maintenance Procedures/Draining Fuel/Water Sepa-
rator Filter” in “Maintaining Your Vehicle” for fur-
ther information.
3. After the “Wait To Start” telltale goes off, turn the ignition switch to the START position. Do not press the
accelerator during starting.
CAUTION!
Do not crank engine for more than 15 seconds at a
time or starter motor damage may result. Turn the
ignition switch to the OFF position and wait at least
two minutes for the starter to cool before repeating
start procedure.
4. After engine start-up, check that the oil pressure warning light has turned off.
5. Allow the engine to idle about three minutes until the manifold heaters have completed the post-heat cycle.
6. Release the parking brake and drive.
NOTE:
•
Engine idle speed will automatically increase to 1,000
RPM and engage the Variable Geometry Turbocharger at
low coolant temperatures to improve engine warm-up.
214 STARTING AND OPERATING
Page 217 of 347
•Automatic equipped vehicles with optional Keyless
Enter-N-Go™ – If the start button is pushed once
while in park with the ignition off and driver ’s foot on
the brake pedal, the vehicle will automatically crank
and start after the Wait to Start time has elapsed. If it is
desired to abort the start process before it completes,
the driver ’s foot should be fully removed from the
brake pedal prior to pushing the start button again in
order for the ignition to move directly to off.
• If the engine stalls, or if the ignition switch is left ON
for more than two minutes after the “Wait To Start”
telltale goes out, reset the grid heaters by turning the
ignition switch to the OFF position for at least five
seconds and then back ON. Repeat steps 1 through 5 of
“Starting Procedure – Engine Manifold Air Tempera-
ture Below 66°F (19°C).”Starting Procedure — Engine Manifold Air
Temperature Below 0°F (-18°C)
In extremely cold weather below 0°F (-18°C) it may be
beneficial to cycle the manifold heaters twice before
attempting to start the engine. This can be accomplished
by turning the ignition OFF for at least five seconds and
then back ON after the “Wait To Start” telltale has turned
off, but before the engine is started. However, excessive
cycling of the manifold heaters will result in damage to
the heater elements or reduced battery voltage.
NOTE:If multiple pre-heat cycles are used before start-
ing, additional engine run time may be required to
maintain battery state of charge at a satisfactory level.
1. If the engine stalls after the initial start, the ignition must be turned to the OFF position for at least five
seconds and then to the ON position to recycle the
manifold heaters.
4
STARTING AND OPERATING 215
Page 218 of 347
NOTE:Excessive white smoke and poor engine perfor-
mance will result if manifold heaters are not recycled.
2. Heat generated by the manifold heaters dissipates rapidly in a cold engine. If more than two minutes
pass between the time the “Wait To Start” telltale turns
off and the engine is started, recycle the manifold
heaters by turning the ignition switch to the OFF
position for at least five seconds and then back ON.
3. If the vehicle is driven and vehicle speed exceeds 19 mph (31 km/h) before the manifold heater post-
heat (after start) cycle is complete, the manifold heat-
ers will shut off.
4. If the engine is started before the “Wait To Start” telltale turns off, the preheat cycle will turn off.
5. If the engine is cranked for more than 10 seconds, the post-heat cycle will turn off. NOTE:
•
Engine idle speed will automatically increase to 1,000
RPM and engage the Variable Geometry Turbocharger
at low coolant temperatures to improve engine warm-
up.
• When a diesel engine is allowed to run out of fuel or
the fuel gels at low temperatures, air is pulled into the
fuel system. If your engine has run out of fuel, refer to
“Maintenance Procedures/Priming If The Engine Has
Run Out Of Fuel” in “Maintaining Your Vehicle” for
further information.
• If the engine stalls, or if the ignition switch is left ON
for more than two minutes after the “Wait To Start”
telltale goes out, reset the grid heaters by turning the
ignition switch to the OFF position for at least five
seconds and then back ON. Repeat steps 1 through 5 of
“Starting Procedure – Engine Manifold Air Tempera-
ture Below 66°F (19°C).”
216 STARTING AND OPERATING
Page 219 of 347
Starting Fluids
WARNING!
Starting fluids or flammable liquids must never be
used in the Cummins® diesel engine (see Warning
label). Never pour diesel fuel, flammable liquid, start-
ing fluids (ether) into the air cleaner canister, air intake
piping, or turbocharger inlet in an attempt to start the
vehicle. This could result in a flash fire and explosion
causing serious personal injury and engine damage.
The engine is equipped with an automatic electric air
preheating system. If the instructions in this manual are
followed, the engine should start in all conditions.
WARNING!
•Do not leave children or animals inside parked
vehicles in hot weather. Interior heat build up may
cause serious injury or death.
• When leaving the vehicle, always make sure the
ignition is in the OFF position, remove the key fob
from the vehicle, and lock the vehicle.
(Continued)
4
STARTING AND OPERATING 217
Page 220 of 347
WARNING!(Continued)
•Never leave children alone in a vehicle, or with
access to an unlocked vehicle. Allowing children to
be in a vehicle unattended is dangerous for a
number of reasons. A child or others could be
seriously or fatally injured. Children should be
warned not to touch the parking brake, brake pedal
or the transmission gear selector. Do not leave the
key fob in or near the vehicle (or in a location
accessible to children), and do not leave the igni-
tion (of a vehicle equipped with Keyless Enter-N-
Go™) in the ACC or ON/RUN mode. A child could
operate power windows, other controls, or move
the vehicle.
NORMAL OPERATION — DIESEL ENGINE
Observe the following when the engine is operating.
• All message center lights are off.
• Malfunction Indicator Light (MIL) is off.
• Engine oil pressure is above 10 psi (69 kPa) at idle.
• Voltmeter operation:
The voltmeter may show a gauge fluctuation at various
engine temperatures. This cycling operation is caused by
the post-heat cycle of the intake manifold heater system.
The number of cycles and the length of the cycling
operation is controlled by the engine control module.
Post-heat operation can run for several minutes, and then
the electrical system and voltmeter needle will stabilize.
The cycling action will cause temporary dimming of the
headlamps, interior lamps, and also a noticeable reduc-
tion in blower motor speed.
218 STARTING AND OPERATING