RENAULT MEGANE SCENIC 1995 Service Repair Manual
Page 1531 of 2492
MECHANISMS OF OPENINGS OTHER THAN SIDE DOORS
Front hood locks
52
AA A A
DD D D
JJ J J
UU U U
SS S S
TT T T
MM M M
EE E E
NN N N
TT T T
12428R
The front part of the hood is positioned by mo-
ving part (2) in order to obtain dimension A = 4
mm.
Tighten the bolts (3) to a torque of 8 N.m.
Refit the trim, the console, the sun visors.
12435R
Hood closed and locked.
52-9
Page 1532 of 2492
MECHANISMS OF OPENINGS OTHER THAN SIDE DOORS
Complete hydraulic system
52
12290R
Disconnect the wiring (1).
Remove the clips (2) and remove the ram.
RR R R
EE E E
MM M M
OO O O
VV V V
AA A A
LL L L
After removing:
- the bench seat cushion and backrest,
- the quarter light trims,
- the boot side fittings
open the hood cover and immobilise it.Remove the connecting crossmember.
PRE5203
12172-1R
Open the bolt (A) as far as possible.
52-10
Page 1533 of 2492
MECHANISMS OF OPENINGS OTHER THAN SIDE DOORS
Complete hydraulic system
52
Remove the rear roof arch ram pin (5) then the
clamp (6). Separate the ram. Remove:
- the main bearing mounting bolts (see section
52).
- the main ram upper clamp.
Separate the main ram from the frame.
Fold the hood.
Disconnect the hood microswitch wiring (left-
hand side)
Detach the hydraulic pipes.
Remove the main bearing mounting bolts.
Raise and immobilise the main bearings in order
to detach the hydraulic system clearance hole.
Remove:
- the electric relays bracket,
- the lower yoke nut (3),
- the ram.
12293R112291R
12289R
52-11
Page 1534 of 2492
MECHANISMS OF OPENINGS OTHER THAN SIDE DOORS
Complete hydraulic system
52
RR R R
EE E E
FF F F
II I I
TT T T
TT T T
II I I
NN N N
GG G G
Insert the rams - pipes assemblies through the
clearance holes in the following order:
1 right-hand side assembly
2 left-hand side assembly
3 hood cover assembly.
Refit the pump.
After refitting all of the components, close the hy-
draulic unit bolt and operate the electrohydraulic
system several times (opening - closing) in order to
purge the hydraulic circuit.
WW W W
AA A A
RR R R
NN N N
II I I
NN N N
GG G G
:: : :
when work is carried out on the hy-
draulic system, follow the recommendations be-
low and keep everything clean.
• Before removal, clean the pipe unions, their
environment and the reservoir carefully.
• Place the system on thick paper. Do not use a
fluffy cloth.
• Cover the system carefully if the work is not
carried out immediately.
• Do not remove the replacement parts from
their packaging until immediately before they
are fitted.
• Do not blow with compressed air when the
hydraulic system is open.
OO O O
NN N N
LL L L
YY Y Y
use EE E E
SS S S
SS S S
OO O O
UU U U
NN N N
II I I
VV V V
II I I
SS S S
JJ J J
22 2 2
66 6 6
OO O O
II I I
LL L L for filling the hy-
draulic system. Disconnect the wiring.
Remove:
- the housing,
- the pump mounting bolts (4),
- the pump.
Remove the rams - pipes assemblies in the follo-
wing order:
1 hood cover assembly
2 left-hand side assembly
3 right-hand side assembly.
12172-1R1
52-12
Page 1535 of 2492
MECHANISMS OF OPENINGS OTHER THAN SIDE DOORS
Hydraulic system (pipes)
52
Remove:
- the pump connectors (1) and wiring,RR R R
EE E E
MM M M
OO O O
VV V V
AA A A
LL L L
After removing the complete system, mark the co-
lour of the connectors (1) on the solenoid valves.
PRE5204
12298R
12297R
- the pump bolts (2) and bracket. B = blue
R = red
52-13
Page 1536 of 2492
MECHANISMS OF OPENINGS OTHER THAN SIDE DOORS
Hydraulic system (pipes)
52
12299R
Diagram of fitting of pipes at the pump end
Unscrew the mounting bolts (3) of the pipe
concerned on the pump distributor (example:
pipe (E) for the hood cover ram).
Remove the pipe from the pump distributor.
Unscrew the union (4) on the ram.
Proceed in the same manner for the pipe (N) as
well as for the other groups of pipes.
RR R R
EE E E
FF F F
II I I
TT T T
TT T T
II I I
NN N N
GG G G
Coat the O-ring with hydraulic oil (change it if ne-
cessary).
NN N N
OO O O
TT T T
EE E E
:: : :
the hydraulic pipes are supplied in pairs
and are marked with letters at the unions.
12486S
12433S
Insert the pie union into the corresponding ope-
ning.
Tighten the bolts to a torque of 7 N.m.
52-14
Page 1537 of 2492
MECHANISMS OF OPENINGS OTHER THAN SIDE DOORS
Hydraulic system (pipes)
52
Diagram of fitting of pipes at the ram end
Pipe Piston rod Piston base end Rams
E X Hood cover
N X Hood cover
A X Left-hand main ram
W X Left-hand main ram
B X Right-hand main ram
X X Right-hand main ram
R X Left-hand rear roof arch
P X Left-hand rear roof arch
S X Right-hand rear roof
arch
O X Right-hand rear roof
arch
Tighten the pipe unions to a torque of 15 N.m.
Refit the pump bracket.
Clip the solenoid valve control connectors (1) and the pump wiring.
52-15
Page 1538 of 2492
MECHANISMS OF OPENINGS OTHER THAN SIDE DOORS
Hydraulic system reservoir
52
PRE5205
RR R R
EE E E
MM M M
OO O O
VV V V
AA A A
LL L L
RR R R
EE E E
FF F F
II I I
TT T T
TT T T
II I I
NN N N
GG G G
Coat the O-ring with hydraulic oil.
Fit the seal in the oil reservoir groove.
Position the reservoir on the pump.
Tighten the bolts (2) to a torque of 7 N.m.
II I I
MM M M
PP P P
OO O O
RR R R
TT T T
AA A A
NN N N
TT T T
:: : :
the hood must be closed when the
hydraulic system is filled.
Fill the reservoir with
EE E E
SS S S
SS S S
OO O O
UU U U
NN N N
II I I
VV V V
II I I
SS S S
JJ J J
22 2 2
66 6 6 oil (capaci-
ty 0.75 l).
The oil level must be between the MINIMUM and
MAXIMUM marks.
The hydraulic system is of the "AUTOMATIC
BLEED" type. The oil level
MM M M
UU U U
SS S S
TT T T
be checked with
the hood open, hood cover closed.
Check the oil level and top up if necessary.
Switch on the ignition, apply the handbrake.
Operate the hood switch.
Open and close the hood several times.
The bleeding process is completed when move-
ment is regular and without jolts with a constant
level of pump noise. Remove:
- the filler bolt (1) and drain,
- the reservoir mounting bolts (2).
12297-1R
52-16
Page 1539 of 2492
GLAZING
Front door window
- the window mounting bolts (3).
Tilt the window towards the rear and remove it.
RR R R
EE E E
MM M M
OO O O
VV V V
AA A A
LL L L
OO O O
FF F F
TT T T
HH H H
EE E E
RR R R
EE E E
AA A A
RR R R
SS S S
LL L L
II I I
DD D D
EE E E
RR R R
54
PRE5401
RR R R
EE E E
MM M M
OO O O
VV V V
AA A A
LL L L
After removing the interior trim,
Remove the slider blanking piece and mountings
(4). remove:
- the side impact bar bolts (1) ,
- the interior weatherstrip,
- the rear guide shoe bolt (2) ,
12276R
12281R 12277-1R
54-1
Page 1540 of 2492
GLAZING
Front door window
AA A A
DD D D
JJ J J
UU U U
SS S S
TT T T
II I I
NN N N
GG G G
TT T T
HH H H
EE E E
WW W W
II I I
NN N N
DD D D
OO O O
WW W W
SS S S
The hood must be folded for the fixed window,
two operators are required to adjust the movable
window.
The door must be adjusted correctly and the
upper movable window stops must be in the
uppermost position.
54
FF F F
II I I
XX X X
EE E E
DD D D
WW W W
II I I
NN N N
DD D D
OO O O
WW W W
Remove the window mounting bolts (5) and the
window pillar mounting bolts (6).
Tilt the assembly (window/pillar) and remove the
window.
FF F F
II I I
XX X X
EE E E
DD D D
WW W W
II I I
NN N N
DD D D
OO O O
WW W W
With the door closed (1st notch), position the
pillar at dimension A = 30 mm high and B = 6
mm from the edge of the windscreen aperture
seal.
12281-1R
12278S
12438R
54-2