lock RENAULT SCENIC 2008 J84 / 2.G Automatic Transmission Siemens TA2000 Workshop Manual

Page 5 of 128

AUTOMATIC TRANSMISSION
Fault finding – Introduction23A
23A - 5V4 MR-372-J84-23A050$066.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
4. FAULT FINDING PROCEDURE (continued)
Wiring check
Fault finding problems
Disconnecting the connectors and/or manipulating the wiring harness may temporarily remove the cause of a fault.
Electrical measurements of the voltage, resistance and insulation are generally correct, especially if the fault is not
present when analysing (stored fault).
Visual inspection
Look for damage under the bonnet and in the passenger compartment.
Carefully check the fuses, insulators and wiring harness routing.
Look for signs of oxidation.
Tactile inspection
While manipulating the wiring harness, use the diagnostic tool to note any change in fault status from stored or
present.
Check that the connectors are correctly locked.
Apply light pressure to the connectors.
Twist the wiring harness.
If there is a change in status, try to locate the source of the fault.
Inspection of each component
Disconnect the connectors and check the appearance of the clips and tabs, as well as the crimping (no crimping on
the insulating section).
Check that the clips and tabs are correctly locked in the sockets.
Make sure that no clips or tabs have been dislodged during connection.
Check the clip contact pressure using an appropriate model of tab.
Check the continuity/insulation
Check the continuity of entire lines, then section by section.
Look for a short circuit to earth, to + 12 V or to another wire.
If a fault is detected, repair or replace the wiring harness.

Page 9 of 128

AUTOMATIC TRANSMISSION
Fault finding – System operation23A
23A-9V4 MR-372-J84-23A050$132.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
MODULAR CONNECTOR
AMultifunction switch
BHydraulic electronic interface
COil pressure sensor
DTurbine speed sensor
EExchanger flow lock-up solenoid valveFemale connection
(connector leading to switch, interface) sensors,
exchanger flow lock-up solenoid valve)Male connection
(connector coming from computer)

Page 10 of 128

AUTOMATIC TRANSMISSION
Fault finding – System operation23A
23A-10V4 MR-372-J84-23A050$132.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
COMPUTER INPUTS AND OUTPUTS
INPUTS OUTPUTS
Diagnostic socket
Automatic
transmission
computer
Solenoid valve control
+ battery feed
+ after ignition feed + warning lights display
Intersystem signals + diagnostic
socketIntersystem signal + diagnostic
socket
Driver actions (brake light switch,
gear selector, multifunction
switch)Gear lever lock

AUTO sensors (turbine speed, oil
pressure, oil temperature)Reversing lights
Earth
Wire connection
Multiplexed connections

Page 13 of 128

AUTOMATIC TRANSMISSION
Fault finding – Replacement of components23A
23A - 13V4 MR-372-J84-23A050$198.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
For SCENIC II only
Reading automatic transmission configuration
The read-configuration commands (LCXXX) are used to display the current computer configuration in relation to the
equipment installed in the vehicle.
Writing automatic transmission configuration
The write-configuration commands (CFXXX) are used to configure the computer for the equipment installed in the
vehicle.
These three settings are important because they optimise transmission operation for the vehicle. If they are not
entered properly, automatic transmission operation may be impaired.Configuration reading Configuration
LC014 Engine torque control function WITH/WITHOUT
LC015 Electronic stability control WITH/WITHOUT
LC017 Shift lock connection fault finding WITH/WITHOUT
Configuration reading Configuration
CF322 Engine torque control function WITH/WITHOUT
CF314 Electronic stability program (ESP) WITH/WITHOUT
CF325 Shift lock connection fault finding WITH/WITHOUT

Page 14 of 128

AUTOMATIC TRANSMISSION
Fault finding – Replacement of components23A
23A - 14V4 MR-372-J84-23A050$198.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
For SCENIC II only
CONFIGURATIONS OF THE AUTOMATIC TRANSMISSION COMPUTER CF322: ENGINE TORQUE CONTROL
FUNCTION
–This function reduces engine torque when shifting gears.
–To apply this configuration, the vehicle must have the ignition on, engine stopped and gear lever in position P
or N.
–This function tells the computer what torque to apply to the engine when changing gears.
–Select configuration CF322 "Engine torque control function".
–Configure the computer WITH or WITHOUT.
–Exit fault finding mode.
–Switch off the ignition.
–Wait 15 seconds for the power-latch to end.
–re-read the configuration for confirmation.
CF314 "ELECTRONIC STABILITY PROGRAM (ESP)"
–This function limits over- or under-steering by braking certain wheels and controlling engine torque.
–To apply this configuration, the vehicle must have the ignition on, engine stopped and gear lever in position P
or N.
–This function lets the automatic transmission computer downshift for ESP adjustments.
–Select configuration CF314 "Electronic stability program (ESP)".
–Configure the computer WITH or WITHOUT.
–Exit fault finding mode.
–Switch off the ignition.
–Wait 15 seconds for the power-latch to end.
–re-read the configuration for confirmation.
CF325 "SHIFT LOCK CONNECTION FAULT FINDING"
–To apply this configuration, the vehicle must have the ignition on, engine stopped and gear lever in position P
or N.
–Select configuration CF325 "Shift lock connection fault finding".
–Configure the computer WITH or WITHOUT.
–Exit fault finding mode.
–Switch off the ignition.
–Wait 15 seconds for the power-latch to end.
–re-read the configuration for confirmation.

Page 15 of 128

AUTOMATIC TRANSMISSION
Fault finding – Fault summary table23A
23A - 15V4 MR-372-J84-23A050$264.mif
SIEMENS TA2000
Vdiag No.: 10-11-15AUTOMATIC TRANSMISSION
Fault finding – Fault summary table
* EVS: Sequence solenoid valvesTool fault Diagnostic tool title
DF002 Computer
DF003 Analogue sensor feed
DF005 Oil pressure sensor circuit
DF009 Multifunction switch prohibited position
DF012 Solenoid valve feed
DF016 Lockup solenoid valve circuit
DF017 Exchanger flow rate solenoid valve circuit
DF018 Lockup slip
DF023 Gearbox oil temperature sensor circuit
DF029 Multifunction switch in unstable position
DF036 Pressure regulating solenoid valve circuit
DF038 Turbine speed sensor circuit
DF048 Vehicle speed signal
DF049 Pressure regulation
DF055 Injection →→ → →
automatic transmission connection
DF064 Display circuit
DF085 EVS*1 sequence solenoid valve circuit
DF086 EVS*2 sequence solenoid valve circuit
DF087 EVS*3 sequence solenoid valve circuit
DF088 EVS*5 sequence solenoid valve circuit
DF089 EVS*4 sequence solenoid valve circuit
DF093 Sequential gear lever circuit
DF095 Shift lock electromagnet circuit
DF109 Engine torque multiplex signal
DF112 *EVS6* sequence solenoid valve circuit
DF114 Pedal position multiplex signal
MR-372-J84-23A050$264.mif

Page 24 of 128

AUTOMATIC TRANSMISSION
Fault finding – Interpretation of faults23A
23A-24V4 MR-372-J84-23A050$330.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
DF016
PRESENT
OR
STOREDLOCKUP SOLENOID VALVE CIRCUIT
CO.0 : Open circuit or short circuit to earth
CC.1 : Short-circuit to + 12 V
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after running command AC024 Sequential actuator control.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connections.
Repair.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V and the
following connections:
●Connection code 5BX between components 119 and 754.
●Connection code 5BA between components 119 and 754.
If the connection(s) are faulty and if there is a repair method (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
Reconnect the modular connector.
Measure the resistance of component 754 between the following connections:
●Connection code 5BX.
●Connection code 5BA.
If the connection(s) are faulty and if there is a repair method (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
Replace the solenoid valve or the electro-hydraulic interface wiring if the resistance is not 1 ΩΩ Ω Ω
± 0.12 ΩΩ Ω Ω
at 20˚C.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the
diagnostic tool.
DP0TA2000_V10_DF016/DP0TA2000_V11_DF016/DP0TA2000_V15_DF016

Page 26 of 128

AUTOMATIC TRANSMISSION
Fault finding – Interpretation of faults23A
23A-26V4 MR-372-J84-23A050$330.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
DF018
PRESENT
OR
STOREDCONVERTER LOCKUP SLIPPAGE
NOTESCarry out injection system fault finding and check that it is operating correctly.
If the following faults are present or stored, deal with them first:
–DF003 Analogue sensor supply.
–DF005 Oil pressure sensor circuit
–DF016 Converter lock-up solenoid valve circuit.
–DF036 Pressure modulating solenoid valve circuit.
–DF038: Turbine speed sensor circuit.
–DF049 Gearbox oil pressure regulation.
Conditions for applying the fault finding procedure to stored faults:
The fault is reported present after driving in fixed 3
rd gear with speed stabilisation for
more than 3 minutes.
To check that there are no faults with the converter lock-up solenoid valve, use the interpretation of fault
DF016 Converter lock-up solenoid valve circuit.
To check that there are no faults with the turbine speed sensor, apply the interpretation of fault DF038 Turbine
speed sensor circuit.
Check gearbox oil grade and level.
If an operation is necessary (see MR 364 Mechanical, 23A, Automatic transmission, Filling-Levels
(for Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Draining-Filling (for Scénic II)).
Check that the transmission is not leaking oil.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2000_V10_DF018/DP0TA2000_V11_DF018/DP0TA2000_V15_DF018

Page 34 of 128

AUTOMATIC TRANSMISSION
Fault finding – Interpretation of faults23A
23A-34V4 MR-372-J84-23A050$330.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
* RR: rear
* FR: frontDF048
PRESENT
OR
STORED
VEHICLE SPEED SIGNAL
1.DEF : No signal
NOTESIf the following faults:
DF117 RR* left-hand wheel speed multiplex signal,
DF118 RR* right-hand wheel speed multiplex signal,
DF175 FR* left-hand wheel speed multiplex signal,
DF176 FR* right-hand wheel speed multiplex signal
are present or stored, deal with these first.
Run a multiplex network test (see 88B, Multiplexing).
If the fault is still present, run fault finding on the Anti-lock braking and Electronic stability program systems
(see 38C, Anti-lock braking system).
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the
diagnostic tool.
DP0TA2000_V10_DF048/DP0TA2000_V11_DF048/DP0TA2000_V15_DF048

Page 35 of 128

AUTOMATIC TRANSMISSION
Fault finding – Interpretation of faults23A
23A-35V4 MR-372-J84-23A050$330.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
DF049
PRESENT
OR
STOREDGEARBOX OIL PRESSURE REGULATION
1.DEF : Pressure regulation
NOTESCarry out injection system fault finding and check that it is operating correctly.
If the following faults are present or stored, deal with them first:
–DF003 Sensor feeds.
–DF005 Oil pressure sensor circuit.
–DF023 Gearbox oil temperature sensor circuit.
–DF036 Pressure modulating solenoid valve circuit.
–DF038: Turbine speed sensor circuit.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
To make sure there are no problems with the pressure lock-up solenoid valve, use the interpretation of fault DF036
Pressure regulating solenoid valve circuit.
Check gearbox oil grade and level.
If an operation is necessary (see MR 364 Mechanical, 23A, Automatic transmission, Filling-Levels
(for Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Draining-Filling (for Scénic II)).
Check that the gearbox is not leaking oil.
Carry out a conformity check to detect any possible faults.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2000_V10_DF049/DP0TA2000_V11_DF049/DP0TA2000_V15_DF049

Page:   1-10 11-20 21-30 31-40 40 next >