PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of commands87B
87B - 257
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of commands87B
87B - 257V9 MR-372-J84-87B000$774.mif
UCH
Vdiag No.: 44, 48,
4C, 4D, 4F, 50
AC015
AIR-CONDITIONING BUTTON INDICATOR LIGHT
Manual air conditioning only
NOTESNo faults should be present or stored.
This command is for testing operation of the air-conditioning indicator light.
Apply the after ignition feed, and the air conditioning control panel should light up.
The command lasts 7 seconds.
Use Wiring Diagrams Technical Note for MEGANE II or SCENIC II.
The indicator light does not light up when the command is activated.
Check the condition and connection of the heater control panel connector.
If the connector is faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check for earth on connection NAM of component 316.
If the connector is faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
With the command running, check for + 12 V feed on connection 38ES of component 316.
If OK, replace the control panel.
Check the condition and connection of connector PE2 on the UCH
If the connector is faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check the insulation and continuity of the following connection:
●Connection code 38ES between components 645 and 319.
●Connection code NAM between component 319 and earth.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact Techline.
AFTER REPAIRCarry out another fault finding check on the system.
Clear the stored faults.
Deal with any other faults.