belt RENAULT SCENIC 2009 J84 / 2.G Air Conditioning Climate Control Workshop Manual

Page 56 of 60

62B-56
CLIMATE CONTROL
Fault finding – Fault Finding Chart62B
V3 MR-372-J84-62B000$110.mif
Vdiag No.: 44
ALP 14 Air conditioning noises during operation
NOTESOnly deal with this customer complaint after a full check with the diagnostic tool
(fault reading and configuration checks).
Check that the computers involved in the air conditioning function (Injection, Protection and
Switching Unit, UCH and Air conditioning control panel) are correctly configured.
Reconfigure if necessary (see 62A, Air conditioning, Configurations and Configuration reading).
Check that:
–the compressor fitted to the vehicle corresponds correctly to the engine (see MR 370 Mechanical, 62A, Air
conditioning, Air conditioning: Parts and consumables for the repair).
Replace the compressor if necessary (see MR 370, Mechanical, 62A, Air conditioning, Compressor: Removal
- Refitting).
–the compressor is correctly fixed (see MR 370 Mechanical, 62A, Air conditioning, Compressor: Removal -
Refitting).
Check the condition of the compressor belt and check its tension. Replace the belt if necessary (see MR 370
Mechanical, 11A, Top and front of engine, Accessories belt: Removal - Refitting).
Check that the intermediate pipes, condenser and dehydrator reservoir are correctly fitted.
–Check the mountings and brackets of the components.
–Check the contact between and proximity of the components.
(see MR 370 Mechanical, 62A, Air conditioning, Air conditioning: List and location of components).
Check the correct operation of the cooling fan assembly or passenger compartment fan assembly and
condenser:
–check the electrical supply of the fan using parameters ET007 High speed fan assembly control, AC009 Low
speed fan assembly and AC010 High speed fan assembly (see 62A, Air conditioning, Conformity check,
Cold loop sub-function).
Check the quantity of refrigerant (see MR 370 Mechanical, 62A, Air conditioning, Air conditioning: Parts
and consumables for the repair).
If the quantity of refrigerant is:
–Greater than the manufacturer's information, recharge according to the manufacturer's values (see MR 370
Mechanical, 62A, Air conditioning: Draining - Filling).
–Less than the manufacturer's information, check for leaks (see MR 370 Mechanical, 62A, Air conditioning,
Refrigerant circuit: Check).
If the fault is still present, replace the compressor (see MR 370, Mechanical, 62A, Air conditioning,
Compressor: Removal - Refitting).
AFTER REPAIRPerform a complete check using the diagnostic tool.
ACREG X84 1.1
Edition 2