charging RENAULT SCENIC 2009 J84 / 2.G Air Conditioning Climate Control Workshop Manual

Page 33 of 60

62B - 33
CLIMATE CONTROL
Fault finding – Interpretation of parameters62B
V3 MR-372-J84-62B000$080.mif
Vdiag No.: 44
PR092
BATTERY VOLTAGE
NOTESNone.
This parameter specifies the supply voltage of the climate control computer.
This parameter should indicate a voltage equal to: 10.5 < X < 14.4 V.
If the voltage is not within the specified range, disconnect connector A (12-track) of the climate control
computer to check the insulation, continuity and absence of interference resistance of the connections:
Computer connector A track 10 + accessories feed (7.5 A fuse in the Protection and
Switching Unit)
Computer connector A track 11 + before ignition feed (20 A fuse of the UCH)
Computer connector A track 6 Earth (left-hand dashboard beam)
Repair if necessary.
If the connections are correct but the fault still persists, perform fault finding on the charging circuit.
AFTER REPAIRRepeat the conformity check from the start.
ACREG X84 1.1
Edition 2