Subsystem: cold loop (continued 1)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
UCHET030:Air conditioning
request 2.ACTIVEIf there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status
represents the request from
the UCH to the injection
computer to engage the
compressor (refer to the
flowchart in the general
operation section).
PR002:Exterior
temperatureX = exterior temperature
± 5 ˚C
(invalid value: 215 ˚C)If there is a fault, refer to the
fault finding procedure
for this parameter.
ET015:Passenger
compartment
blower.ACTIVE
(according to test
conditions: see Notes).If there is a fault, refer to the
fault finding procedure
for this status.
Note: This status is only
operative for manual air
conditioning(and heater
versions without air
conditioning).
ET091:Engine running:YES
NOTE: This status is
displayed by the UCH but it
is generated by the injection
computer.If there is a fault, refer to the
fault finding procedure
for this status.
(Injection Technical Note).
InjectionET079:Air conditioning
present.YES
(automatic injection
computer configuration).If the status displays NO,
consult the fault finding
procedure for this status.
PR064:Coolant
temperature.X = engine coolant
temperature.If there is a fault, refer to the
fault finding procedure
for this parameter.
ET004:Air conditioning
authorisation.YESIf the status displays NO,
consult the fault finding
procedure for this status.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif

Page 32 of 60

62A - 32
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: cold loop (continued 2)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
Injection
(continued 1)ET088:Compressor
activation request.ACTIVEIf the status displays
INACTIVE, consult the
fault finding procedure
for this status.
NOTE: This status
represents the request from
the injection computer to
the Protection and
Switching Unit to engage
the compressor (refer to the
flowchart in the general
operation section).
PR089:Vehicle speed.0 mph (0 km/h) If there is a fault, refer to the
fault finding procedure
for this parameter.
PR055:Engine speed. 800 rpm.If there is a fault, refer to the
fault finding procedure
for this parameter.
ET023:Fast idle request
(except EDC 16
injection).PRESENTIf there is a fault: refer to the
fault finding procedure
for this status.
NOTE: This status is not
displayed by the EDC16
injection (F9Q engine).
PR053:Engine speed
requested by air
conditioning
(except S3000 and
DDCR injections).800 rpm.If there is a fault, refer to the
fault finding procedure
for this parameter.
NOTE: This parameter is
only displayed by the
EDC16 injection (F9Q
engine).
PR037:Refrigerant
pressure.1 bar < X < 35 barIf there is a fault, refer to the
fault finding procedure
for this parameter.
PR125:Power absorbed
by air conditioning
compressor.300 W < X < 5000 W
(ambient temperature
23 ˚C)If there is a fault, refer to the
fault finding procedure
for this parameter.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif

Page 33 of 60

62A - 33
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: cold loop (continued 3)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
Injection
(continued 2)ET022:Low speed fan
request (except
3000 injection)ACTIVE if the refrigerant
fluid pressure is less
than
23 bar
INACTIVE otherwise
NOTE: This status is not
displayed by the S3000
injection (K4J, K4M, F4R
and F4RT engines).If there is a fault, refer to the
fault finding procedure
for this status.
–For more information
(Control of Fan 1 or
Fan 2 according to
vehicle speed and
refrigerant fluid
pressure), refer to the
HELP section (62B).
ET021:High speed fan
request (except
S3000 injection).ACTIVE if the refrigerant
fluid pressure is more
than
23 bar
INACTIVE otherwise
NOTE: This status is not
displayed by the S3000
injection (K4J, K4M, F4R
and F4RT engines).If there is a fault, refer to the
fault finding procedure
for this status.
–For more information
(Control of Fan 1 or
Fan 2 according to
vehicle speed and
refrigerant fluid
pressure), refer to the
HELP section (62B).
ET014:Fan unit 1 check
(except DDCR
injection).RUNNING if the refrigerant
fluid pressure is less
than
23 bar
OFF otherwiseIf there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is not
displayed by the DDCR
injection (K9K engine).
ET015:Fan unit 2 check
(except DDCR
injection).RUNNING if the refrigerant
fluid pressure is more
than
23 bar
OFF otherwiseIf there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is not
displayed by the DDCR
injection (K9K engine).
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif

Page 34 of 60

62A - 34
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: cold loop (continued 4)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
Protection and
Switching UnitET007:High speed fan
control.INACTIVE
(On Mégane saloons and
sport hatches this status is
always ACTIVE: ignore it
).If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is only
operative on Mégane
Scénics (2 engine cooling
fans and Fan unit 2 relay
outside the UPC).
AC008:Compressor
control.Command for testing the
operation of the air
conditioning compressor
clutch.If there is a fault, consult the
fault finding procedure
for this command.
NOTE: The UPC cannot
test the compressor control
circuit, this command is the
only way to test its
operation.
AC009:Low speed fan
unit.Command for testing the
low speed operation of the
engine cooling fan unit
(Fan 1).If there is a fault, consult the
fault finding procedure
for this command.
NOTE: The UPC cannot
test the control circuit for
Fan unit 1; this command is
the only way to test its
operation.
AC010:High speed fan
unitCommand for testing the
high speed operation of
the engine cooling fan unit
(Fan 2).If there is a fault, consult the
fault finding procedure
for this command.
NOTE: On Mégane saloons
and sport hatches the UPC
cannot test the control
circuit for Fan unit 2; this
command is the only way to
test its operation.
On Mégane Scénics, the
Fan unit 2 control relay is
outside the UPC and its
control line is tested by
(DF002 High speed fan
control relay circuit).
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif

Page 35 of 60

62A - 35
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: heating
NOTESOnly carry out this conformity check after a full check with the diagnostic tool (fault
reading and configuration checks).
Test conditions: engine at idle speed,
AIR CONDITIONING OPERATING (air
conditioning compressor engaged).
NOTE: The interpretation of the statuses, parameters and controls listed in this check
is explained in the Technical Notes relating to the computer which generates the signal
(see the Introduction section).
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
Climate controlET086:Heated rear
screen: manual
mode.ACTIVE: De-icing button at
the bottom of the control
panel pressed.
INACTIVE otherwise.If there is a fault, refer to the
fault finding procedure
for this status.
ET085:Heated rear
screen: auto
mode.ACTIVE: De-icing button at
the top of the control panel
pressed ("See clear"
function).
INACTIVE otherwise.If there is a fault, refer to the
fault finding procedure
for this status.
PR121:Blown air
temperature
setpoint.0 < X < 80 ˚C.If there is a fault, refer to the
fault finding procedure
for this parameter.
PR001:Interior
temperature.X = interior temperature
± 5 ˚C
(invalid value: 87.5 ˚C).If there is a fault, refer to the
fault finding procedure
for this parameter.
PR012:Mixing flap
position.0% = Max. cold position
(15 ˚C)
100% = Max. warm position
(27 ˚C)If there is a fault, refer to the
fault finding procedure
for this parameter.
ET141:Passenger
compartment
blower.RUNNING.
(according to test
conditions: see Notes).If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is only
operative for climate
control systems.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif

Page 36 of 60

62A - 36
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: heating (continued 1)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
UCHPR001:Battery voltage.12.5 < X < 14.4 volts.If there is a fault, refer to the
fault finding procedure
for this parameter. If the
fault is still present, carry
out fault finding on the
charge circuit.
PR002:Exterior
temperature.X = exterior temperature
± 5˚C
(invalid value: 215 ˚C).If there is a fault, refer to the
fault finding procedure
for this parameter.
ET025:Retractable roof.CLOSED or NOT CLOSED
ABSENT if the vehicle does
not have one.If there is a fault, refer to the
fault finding procedure
for this status.
ET091:Engine running:YES
NOTE: This status is
displayed by the UCH but it
is generated by the injection
computer.If there is a fault, refer to the
fault finding procedure
for this status.
(Injection Technical Note).
ET015:Passenger
compartment
blower.ACTIVE
(according to test
conditions: see Notes).If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is only
operative for manual air
conditioning(and heater
versions without air
conditioning).
ET026:Heated rear
screen switch.ACTIVE if the heated rear
screen is operating.
INACTIVE otherwise.If there is a fault, refer to the
fault finding procedure
for this status.
ET031:Fast idle request
for RCH.ACTIVE if the RCH are
operating.
INACTIVE otherwise.If there is a fault, refer to the
fault finding procedure
for this status.
ET017:Number RCH
required.0, 1, 2 or 3 for Mégane
saloons and sport hatches
(1000 watt RCH).
0, 1, 2, 3, 4 or 5 for Mégane
Scénics (1800 watt RCH).
(according to heat
requirement).If there is a fault, refer to the
fault finding procedure
for this status.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif

Page 37 of 60

62A - 37
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: heating (continued 2)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
UCH
(continued 1)ET018:Number RCH
authorised by
alternator.0, 1, 2 or 3 for Mégane
saloons and sport hatches
(1000 watt RCH).
0, 1, 2, 3, 4 or 5 for Mégane
Scénics (1800 watt RCH).
(depending on the electrical
availability).If there is a fault, refer to the
fault finding procedure
for this status.
ET019:Number RCH
authorised by
injection.0, 1, 2 or 3 for Mégane
saloons and sport hatches
(1000 watt RCH).
0, 1, 2, 3, 4 or 5 for Mégane
Scénics (1800 watt RCH).
(according to the injection's
requirements: power
requirement, torque
reduction, etc.).If there is a fault, refer to the
fault finding procedure
for this status.
ET020:Number RCH
actuated.0, 1, 2 or 3 for Mégane
saloons and sport hatches
(1000 watt RCH).
0, 1, 2, 3, 4 or 5 for Mégane
Scénics (1800 watt RCH).
(depending on statuses
"ET017, ET018 and
ET019").If there is a fault, refer to the
fault finding procedure
for this status.
ET021:RCH no. 1 control
relay.ACTIVE or INACTIVE
(depending on status
ET020).If there is a fault, refer to the
fault finding procedure
for this status.
ET022:RCH no. 2 control
relay.ACTIVE or INACTIVE
(depending on status
ET020).If there is a fault, refer to the
fault finding procedure
for this status.
ET023:RCH no. 3 control
relay (Mégane
Scénic and
Scénic 4x4 only).ACTIVE or INACTIVE
(depending on status
ET020).If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is
inoperative for Mégane
saloons and Mégane sport
hatches.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif

Page 38 of 60

62A - 38
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: heating (continued 3)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
UCH
(continued 2)AC016:RCH no. 1 relay. Commands for testing the
operation of the RCH
(passenger compartment
air heating resistors). The
number of RCH stages
switched on depends on the
number of relays actuated.
NOTE: RCH no. 3 relay is
only fitted to Mégane
Scénics.If there is a fault, refer to the
fault finding procedure
for these controls.
NOTE: To find the relays
actuated/number of RCH
engaged correlation, refer
to the "general operation"
section of the UCH
Technical Note. AC017:RCH no. 2 relay.
AC018:RCH no. 3 relay.
(Mégane Scénics
only)
InjectionET024:Set number of
RCH.YES or NO
NOTE: According to the
injection's requirements:
power requirement, torque
reduction, etc., the injection
computer sets the number
of RCH stages switched on
(no more, no less).If there is a fault, refer to the
fault finding procedure
for this status.
PR064:Coolant
temperature.X = engine coolant
temperature.If there is a fault, refer to the
fault finding procedure
for this parameter.
Protection and
Switching UnitPR002:alternator charge
signal0 < X <100 %
–0 % = zero electrical
consumption.
–100 % = maximum
electrical consumption.If there is a fault, refer to the
fault finding procedure
for this parameter.
AC011:Heated rear
screen.Command for testing the
operation of the rear screen
heating.If there is a fault, consult the
fault finding procedure
for this command.
NOTE: The UPC cannot
test the heated rear screen
control circuit; this
command is the only way to
test its operation.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif

Page 39 of 60

62A - 39
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: user selection
NOTESOnly carry out this conformity check after a full check with the diagnostic tool (fault
reading and configuration checks).
Test conditions: engine at idle speed,
AIR CONDITIONING OPERATING (air
conditioning compressor engaged).
NOTE: The interpretation of the statuses, parameters and controls listed in this check
is explained in the Technical Notes relating to the computer which generates the signal
(see the Introduction section).
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
Climate controlET086:Heated rear
screen: manual
mode.ACTIVE: De-icing button at
the bottom of the control
panel pressed.
INACTIVE otherwise.If there is a fault, refer to the
fault finding procedure
for this status.
ET085:Heated rear
screen: auto
mode.ACTIVE: De-icing button at
the top of the control panel
pressed ("See clear"
function).
INACTIVE otherwise.If there is a fault, refer to the
fault finding procedure
for this status.
ET143:Air conditioning
request 1.ACTIVE
NOTE: This status is only
valid for climate control
systems.If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status
represents the request from
the climate control
computer to the UCH to
engage the compressor
(refer to the flowchart in
the general operation
section).
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif

Page 40 of 60

62A - 40
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: user selection (continued)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
UCHET029:Air conditioning
button.PRESSED
(AC button on the manual
air conditioning control
panel pressed).If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is only
operative for manual air
conditioning.
ET028:Heated rear
screen button.PRESSED if the heated
rear screen button on the
air conditioning control
panel is pressed.
RELEASED otherwise.If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is only
operative for manual air
conditioning(and heater
versions without air
conditioning).
ET015:Passenger
compartment
blower.ACTIVE
(according to test
conditions: see Notes).If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is only
operative for manual air
conditioning(and heater
versions without air
conditioning).
AC015:Air conditioning
button light.Command enabling the air
conditioning button light to
be illuminated to check its
operation.If there is a fault, consult the
fault finding procedure
for this command.
NOTE: This command only
operates for manual air
conditioning.
AC019:Heated rear
screen indicator
light.Command enabling the
heated rear screen button
light to be illuminated to
check its operation.If there is a fault, consult the
fault finding procedure
for this command.
NOTE: This command only
operates for manual air
conditioning (and heater
versions without air
conditioning).
CLIM X84 1.1