ABS RENAULT SCENIC 2010 J95 / 3.G Air Conditioning Workshop Manual

Page 2 of 60

62A - 2
AIR CONDITIONING
ABBREVIATIONS62A
V4
Manual air conditioning
and
Climate control
ABBREVIATIONS MEANING OF ABBREVIATION
ABS systemAnti-lock braking system
Fault Finding Chart Fault Finding Chart
APCAfter ignition
AVCBefore ignition feed
BVAAutomatic gearbox
Manual gearboxManual gearbox
BVRSequential gearbox
CANController Area Network
ACAir conditioning
CDCompact disc
PASPower assisted steering (hydraulic)
DAEElectric power assisted steering
DVDDigital versatile disc
DTCFault finding code
EGRExhaust gas recirculation
ESPElectronic Stability Program
GMVFan assembly
CNGCompressed natural gas
LPG Liquefied petroleum gas
HLEHigh yield strength
MAGMetal active gas (for welding steel)
MIGMetal inert gas (for welding aluminium)
MRWorkshop repair manual
TNTechnical Note
OBDOn board diagnostics
SERResistance spot welding
SSPPTyre pressure monitoring system
THLEVery high-tensile strength
TMLabour time
UCHUCH
UPCProtection and switching unit
UCTRoof control unit
UHLEUltra high yield strength
VINVehicle identification number
162AAIR CONDITIONING
ABBREVIATIONS
MR-372-J84-62A000$010.mif

Page 19 of 60

62A - 19
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: cold loop (continued 2)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
Injection
(continued 1)ET088:Compressor
activation request.INACTIVE
(engagement of the
compressor is only
authorised when the engine
is running).If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status
represents the request from
the injection computer to
the Protection and
Switching Unit to engage
the compressor (refer to the
flowchart in the general
operation section).
PR089:Vehicle speed.0 mph or km/h If there is a fault, refer to the
fault finding procedure
for this parameter.
PR055:Engine speed.0 rpm.If there is a fault, refer to the
fault finding procedure
for this parameter.
ET023:Fast idle request
(except EDC 16
injection).ABSENTIf there is a fault: refer to the
fault finding procedure
for this status.
NOTE: This status is not
displayed by the EDC16
injection (F9Q engine).
PR053:Engine speed
required by air
conditioning
(except S3000 and
DDCR injections).0 rpm.If there is a fault, refer to the
fault finding procedure
for this parameter.
NOTE: This parameter is
only displayed by the
EDC16 injection (F9Q
engine).
PR037:Refrigerant
pressure.1 bar < X < 35 barIf there is a fault, refer to the
fault finding procedure
for this parameter.
PR125:Power absorbed
by AC
compressor.0 W < X < 300 W
(ambient temperature
23 ˚C)If there is a fault, refer to the
fault finding procedure
for this parameter.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif

Page 23 of 60

62A - 23
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: heating (continued 1)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
UCHPR001:Battery voltage.10.5 < X < 14.4 volts.If there is a fault, refer to the
fault finding procedure
for this parameter. If the
fault is still present, carry
out a fault finding test on
the charge circuit.
PR002:Exterior
temperature.X = exterior temperature
± 5 ˚C
(invalid value: 215 ˚C).If there is a fault, refer to the
fault finding procedure
for this parameter.
ET025:Retractable roof.CLOSED or NOT CLOSED
ABSENT if the vehicle does
not have one.If there is a fault, refer to the
fault finding procedure
for this status.
ET091:Engine running:NO
NOTE: This status is
displayed via the UCH but it
is generated by the injection
computer.If there is a fault, refer to the
fault finding procedure
for this status.
(Injection Technical Note).
ET015:Passenger
compartment
blower.INACTIVE
(according to test
conditions: see Notes).If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is only
operative for manual air
conditioning (and heater
versions without air
conditioning).
ET026:Heated rear
screen switch.INACTIVE
(Inhibited with engine
stopped).If there is a fault, refer to the
fault finding procedure
for this status.
ET031:Fast idle request
for RCH.INACTIVE
(Inhibited with engine
stopped).If there is a fault, refer to the
fault finding procedure
for this status.
ET017:Number RCH
required.0, 1, 2 or 3 for Mégane
saloons and sport hatches
(1000 watt RCH).
0, 1, 2, 3, 4 or 5 for Mégane
Scénics (1800 watt RCH).
(according to heat
requirement).If there is a fault, refer to the
fault finding procedure
for this status.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif

Page 32 of 60

62A - 32
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: cold loop (continued 2)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
Injection
(continued 1)ET088:Compressor
activation request.ACTIVEIf the status displays
INACTIVE, consult the
fault finding procedure
for this status.
NOTE: This status
represents the request from
the injection computer to
the Protection and
Switching Unit to engage
the compressor (refer to the
flowchart in the general
operation section).
PR089:Vehicle speed.0 mph (0 km/h) If there is a fault, refer to the
fault finding procedure
for this parameter.
PR055:Engine speed. 800 rpm.If there is a fault, refer to the
fault finding procedure
for this parameter.
ET023:Fast idle request
(except EDC 16
injection).PRESENTIf there is a fault: refer to the
fault finding procedure
for this status.
NOTE: This status is not
displayed by the EDC16
injection (F9Q engine).
PR053:Engine speed
requested by air
conditioning
(except S3000 and
DDCR injections).800 rpm.If there is a fault, refer to the
fault finding procedure
for this parameter.
NOTE: This parameter is
only displayed by the
EDC16 injection (F9Q
engine).
PR037:Refrigerant
pressure.1 bar < X < 35 barIf there is a fault, refer to the
fault finding procedure
for this parameter.
PR125:Power absorbed
by air conditioning
compressor.300 W < X < 5000 W
(ambient temperature
23 ˚C)If there is a fault, refer to the
fault finding procedure
for this parameter.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif

Page 36 of 60

62A - 36
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: heating (continued 1)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
UCHPR001:Battery voltage.12.5 < X < 14.4 volts.If there is a fault, refer to the
fault finding procedure
for this parameter. If the
fault is still present, carry
out fault finding on the
charge circuit.
PR002:Exterior
temperature.X = exterior temperature
± 5˚C
(invalid value: 215 ˚C).If there is a fault, refer to the
fault finding procedure
for this parameter.
ET025:Retractable roof.CLOSED or NOT CLOSED
ABSENT if the vehicle does
not have one.If there is a fault, refer to the
fault finding procedure
for this status.
ET091:Engine running:YES
NOTE: This status is
displayed by the UCH but it
is generated by the injection
computer.If there is a fault, refer to the
fault finding procedure
for this status.
(Injection Technical Note).
ET015:Passenger
compartment
blower.ACTIVE
(according to test
conditions: see Notes).If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is only
operative for manual air
conditioning(and heater
versions without air
conditioning).
ET026:Heated rear
screen switch.ACTIVE if the heated rear
screen is operating.
INACTIVE otherwise.If there is a fault, refer to the
fault finding procedure
for this status.
ET031:Fast idle request
for RCH.ACTIVE if the RCH are
operating.
INACTIVE otherwise.If there is a fault, refer to the
fault finding procedure
for this status.
ET017:Number RCH
required.0, 1, 2 or 3 for Mégane
saloons and sport hatches
(1000 watt RCH).
0, 1, 2, 3, 4 or 5 for Mégane
Scénics (1800 watt RCH).
(according to heat
requirement).If there is a fault, refer to the
fault finding procedure
for this status.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif