ECU RENAULT SCENIC 2010 J95 / 3.G Air Conditioning Workshop Manual

Page 4 of 60

62A - 4
AIR CONDITIONING
Fault finding - Introduction62A
V4
Manual air conditioning
and
Climate control
Faults
Faults are declared either present or stored (depending on whether they appeared in a certain situation and have
disappeared since, or whether they remain but have not been diagnosed within the current context).
The present or stored status of faults should be taken into consideration when the diagnostic tool is used after the
+ after ignition feed has been supplied (without acting on the system components).
For a present fault, apply the procedure described in the Interpretation of faults section.
For a stored fault, note the faults displayed and apply the notes section.
If the fault is confirmed when the Notes are applied, the fault is present. Deal with the fault
If the fault is not confirmed, check:
–the electrical lines which correspond to the fault,
–the connectors for these lines (for oxidation, bent pins, etc),
–the resistance of the component detected as faulty,
–The condition of the wires (insulation melted or split, chafing, etc.).
Conformity check
The aim of the conformity check is to check statuses and parameters that do not produce a fault display on the
diagnostic tool when inconsistent. Therefore, this phase is used to:
–carry out fault finding on faults that do not have a fault display, and which may correspond to a customer complaint.
–check that the system is operating correctly and that there is no risk of a fault recurring after repairs.
This section features the fault finding procedures for statuses and parameters, and the conditions for checking them.
If a status is not behaving normally or a parameter is outside the permitted tolerance values, consult the
corresponding fault finding page.
Notes about the conformity check for the climate control system
The air conditioning system conformity check is divided into four parts. The parts relate to the four air conditioning
subsystems, heater, cold loop, user selection and passenger compartment ventilation.
The statuses and parameters related to these sub-functions are listed with their respective computers.
NOTE: the manual air conditioning control panel does not control electrical components and cannot be subjected to
fault finding. Therefore, there is no conformity check in the 62C Manual air conditioning section.
Customer complaints – Fault finding charts
If the test with the diagnostic tool is OK, but the customer complaint persists, the fault should be treated by
customer complaints. Note:
The interpretation of statuses, parameters and commands is also split into several sections. Everything controlled
by the air conditioning control panel is explained in the two Air conditioning sections, 62A and 62B. By contrast,
signals from other computers are explained in the "fault finding" sections for these computers (see the conformity
check).
A synopsis of the general procedure to follow is provided on the following
page in the form of a flowchart.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$020.mif