AFTER REPAIRDeal with any faults displayed by the diagnostic tool. Clear the computer fault
memory.
Carry out a road test followed by another check with the diagnostic tool.
V10 MR-372-J84-13B100$170.mif
DIESEL INJECTION
Fault finding – Interpretation of parameters13B
DCM 1.2 Injection
Program No.: 4D
Vdiag No.: 48, 4C, 50,
54, 58, 5C
PR125POWER ABSORBED BY THE AIR CONDITIONING COMPRESSOR*
PARAMETER
DEFINITIONThis parameter indicates the power absorbed by the air conditioning compressor in W.
Conformity check: Engine stopped and ignition on, or engine running without electrical consumer,
and engine coolant temperature > 80
°C
PR125 = 0 W
Conformity check: With engine running and compressor activation request active
PR125 = 1200 W
DCM1.2_V48_PR125/DCM1.2_V4C_PR125/DCM1.2_V50_PR125/DCM1.2_V54_PR125/DCM1.2_V58_PR125/DCM1.2_V5C_PR125

Page 206 of 269

13B-206V10 MR-372-J84-13B100$180.mif
DIESEL INJECTION
Fault finding – Command summary table13B
DCM 1.2 Injection
Program No.: 4D
Vdiag No.: 48, 4C, 50,
54, 58, 5C
AC153* High-speed fan assemblyThis command enables the high-speed fan assembly to be
controlled. In the event of a fault, consult the interpretation of
fault DF019 High speed fan assembly control circuit.
Except Vdiag48 and 4C.
AC154* Low-speed fan assemblyThis command enables the low-speed fan assembly to be
controlled. In the event of a fault, consult the interpretation of
fault DF018 Low speed fan assembly control circuit.
Except Vdiag48 and 4C.
AC180*Air conditioning compressor
relay controlThis activation allows the air conditioning compressor clutch
relay to be controlled. In the event of a fault, refer to the
interpretation of DF489 Air conditioning compressor
control.
AC212 New pump chamber fillingActivates New pump chamber filling next time the vehicle is
started.
AC250 Heating resistor 1 relayThis activation enables the heating resistor 1 relay to be
controlled. If there is a fault, refer to the interpretation of fault
DF032 Thermoplunger 1 relay control circuit.
Only for Vdiag 50.
AC251 Heating resistor 2 relayThis activation enables the heating resistor 2 relay to be
controlled. If there is a fault, refer to the interpretation of fault
DF033 Thermoplunger 2 relay control circuit.
Only for Vdiag 50.
SC001 Write saved dataUse this command after replacing or (re)programming the
computer (if the data has been saved using command SC003).
SC002 Enter injector codesThis command enables you to manually write the calibration
code marked on the injectors. Run this command after
replacing the injectors.
SC003 Save computer dataThis command enables the computer operating data
and the engine adaptives to be recorded.
SC040 Speed limiterThis command enables the vehicle speed restriction to be
modified. Run this command after replacing or
(re)programming.
This command applies only on Kangoo 2
SC041Changing commercial
vehicle idle speedThis command enables the idle speed to be modified. Run this
command after replacing or (re)programming.
This command applies only on Kangoo 2
Tool