Fault finding - Interpretation of faults
17B
17B-40
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-40V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF026
PRESENT
OR
STOREDCYLINDER 1 INJECTOR CONTROL CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short-circuit to + 12 V
1.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
Deal with faults DF084 Actuator relay control circuit or DF046 Battery voltage first
if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine has been running for a timed period of
10 seconds.
Special note:
–OBD warning light illuminated.
CO
CC.1
NOTESSpecial note:
No injection on cylinder 1, severe deterioration in
performance.
CC.0Special note:
The injector is always open: risk of stalling and damage to
the engine on starting, severe deterioration in performance.
Check the cleanliness and condition of the cylinder 1 injector and its connections.
Repair if necessary.
With the ignition on, check for + 12 V on track 1 of the cylinder 1 injector connector.
If there is no + 12 V feed, use the "universal bornier" to check the continuity of the following connections:
Injection computer, connectorB, track M2 track 1 of cylinder 1 injector
Protection and Switching Unit, connector CN,
track 6
Repair if necessary.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF026/S3000_V54_DF026

Page 42 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-42
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-42V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF027
PRESENT
OR
STOREDCYLINDER 2 INJECTOR CONTROL CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short-circuit to + 12 V
1.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
Deal with faults DF084 Actuator relay control circuit or DF046 Battery voltage first
if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine has been running for a timed period of
10 seconds.
Special note:
–OBD warning light illuminated.
CO
CC.1
NOTESSpecial note:
No injection on cylinder 2 and marked loss of performance.
CC.0Special note:
The injector is always open: risk of stalling and damage to
the engine on starting, severe deterioration in performance.
Check the cleanliness and condition of the cylinder 2 injector and its connections.
Repair if necessary.
With the ignition on, check for + 12 V on track 1 of the cylinder 2 injector connector.
If there is no + 12 V feed, use the "universal bornier" to check the continuity of the following connections:
Injection computer, connectorB, track M2 track 1 of cylinder 2 injector
Protection and Switching Unit, connector CN,
track 6
Repair if necessary.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF027/S3000_V54_DF027

Page 44 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-44
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-44V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF028
PRESENT
OR
STOREDCYLINDER 3 INJECTOR CONTROL CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short-circuit to + 12 V
1.DEF: Non-compliance with emission control standards
NOTESOrder of priority in the event of more than one fault:
Deal with faults DF084 Actuator relay control circuit or DF046 Battery voltage first
if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine has been running for a timed period of
10 seconds.
Special note:
–OBD warning light illuminated.
CO
CC.1
NOTESSpecial note:
No injection on cylinder 3, severe deterioration in
performance.
CC.0Special note:
The injector is always open: risk of stalling and damage to
the engine on starting, severe deterioration in performance.
Check the cleanliness and condition of the cylinder 3 injector and its connections.
Repair if necessary.
With the ignition on, check for + 12 V on track 1 of the cylinder 3 injector connector.
If there is no + 12 V feed, use the "universal bornier" to check the continuity of the following connections:
Injection computer, connectorB, track M2 track 1 of cylinder 3 injector
Protection and Switching Unit, connector CN,
track 6
Repair if necessary.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF028/S3000_V54_DF028

Page 46 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-46
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-46V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF029
PRESENT
OR
STOREDINJECTOR CYLINDER 4 CONTROL CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short-circuit to + 12 V
1.DEF: Non-compliance with emission control standards
NOTESOrder of priority in the event of more than one fault:
Deal with faults DF084 Actuator relay control circuit or DF046 Battery voltage first
if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine has been running for a timed period of
10 seconds.
Special note:
–OBD warning light illuminated.
CO
CC.1
NOTESSpecial note:
No injection on cylinder 4, severe deterioration in
performance.
CC.0Special note:
The injector is always open: risk of stalling and damage to
the engine on starting, severe deterioration in performance.
Check the cleanliness and condition of the cylinder 4 injector and its connections.
Repair if necessary.
With the ignition on, check for + 12 V on track 1 of the cylinder 4 injector connector.
If there is no + 12 V feed, use the "universal bornier" to check the continuity of the following connections:
Injection computer, connectorB, track M2 track 1 of the cylinder 4 injector
Protection and Switching Unit, connector CN,
track 6
Repair if necessary.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF029/S3000_V54_DF029

Page 49 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-49
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-49V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF046
PRESENT
BATTERY VOLTAGE
1.DEF: Abnormal voltage
NOTESPriority when dealing with a number of faults:
Apply the procedure for dealing with fault DF084 Actuators relay control circuit first
if it is present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present with the engine running.
Special note:
–level 1 fault warning light illuminated.
– throttle valve defect mode types 1 and 2 in the event of undervoltage: vehicle and
engine speed restriction, the ESP and cruise control/speed limiter are deactivated.
Disconnect the battery and the injection computer.
Check the cleanliness and condition of the computer connections.
Repair if necessary.
Disconnect the CN and MN connector of the Protection and Switching Unit.
Check the cleanliness and condition of its connections.
Use the Universal bornier to check the continuity of the following connections:
Injection computer, connectorB, track M2Protection and Switching Unit, connector CN,
track 6
Injection computer, connectorB, track D4Protection and Switching Unit, connector MN,
track 5
Repair if necessary.
– clean the battery terminals and all connections to + and the Earth,
– check the battery voltage,
– check the charging circuit (see Technical Note 6014A Checking the charging circuit).
Repair or replace the faulty components, if necessary.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF046P/S3000_V54_DF046P

Page 50 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-50
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-50V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF054
PRESENT
OR
STOREDTURBOCHARGING SOLENOID VALVE CONTROL CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short-circuit to + 12 V
1.DEF: Non-compliance with emission control standards
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the ignition is switched on or with then engine
running at an engine speed above 600 rpm.
Special note:
–for F4R-Turbo only,
–OBD warning light illuminated.
– Throttle valve defect mode type 6.
Check the cleanliness, condition and fitting of the turbocharging solenoid valve.
Repair if necessary.
If the fault is still present, manipulate the harness to note any change in fault status (present↔ stored).
Look for possible damage to the wiring harness, check the condition and connection of the connectors of the
injection computer and turbocharging solenoid valve.
Repair if necessary.
If the fault is still present, check (with the ignition on) for +12V on track 2 of the turbocharging solenoid valve.
If there is no + 12 V, check the insulation, continuity and the absence of interference resistance on the
following connections:
Injection computer, connectorB, track M2 track 2 of the turbocharging solenoid valve
Main relay
Repair if necessary.
If the fault is still present, disconnect the battery and the injection computer.
Check the insulation, continuity and the absence of interference resistance on the following connections:
Injection computer, connectorC track G4 track 1 of the turbocharging solenoid valve
Repair if necessary.
If the fault is still present, measure the resistance of the turbocharging solenoid valve between tracks 1 and 2.
Replace the turbocharging solenoid valve if the resistance is not 30Ω ±2Ω at 23°C.
If the fault is still present, deal with the other faults then proceed to the conformity check.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF054/S3000_V54_DF054

Page 51 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-51
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-51V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF059
PRESENT
OR
STOREDCOMBUSTION MISFIRES ON CYLINDER 1
1.DEF: Destructive misfiring
2.DEF: Polluting misfiring
3.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
– ignition: DF361 Ignition coil circuit cylinders 1-4
DF362 Ignition coil circuit cylinders 2-3
– fuel supply circuit:
DF026 Injector control circuit cylinder 1,
DF027 Injector control circuit cylinder 2,
DF028 Injector control circuit cylinder 3,
DF029 Injector control circuit cylinder 4,
DF085 Fuel pump relay control circuit.
– engine flywheel signal: DF154 Flywheel signal sensor circuit
DF457 Flywheel target
Check whether there are other cylinders with a combustion misfire fault detected by the
tool before starting the following fault finding procedure.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present under the following conditions:
– there must be no further electrical faults,
– programming must be carried out.
– warm engine (coolant temperature 75°C minimum),
– engine running at idling speed with all electrical consumers on for approximately
15 minutes.
Special note:
–OBD warning light illuminated.
1.DEF
NOTESSpecial note:
– As soon as the fault is detected, the injection is cut off on
the faulty cylinder(s) to limit the temperature increase in
the catalytic converter,
– if a fault is present, the OBD warning light flashes.
2.DEFSpecial note:
–the OBD warning light remains continuously lit.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF059/S3000_V54_DF059

Page 52 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-52
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-52V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF059
CONTINUED
Misfiring on
cylinder 1 only
Combustion
misfires in
cylinders 1 and 4
(see DF059
Combustion
misfires in
cylinder 1 and
DF062 Combustion
misfires in
cylinder 4)
Combustion
misfires on all four
cylinders (see
DF060, DF061 and
DF062)
The fault is probably due to a component that can only affect this cylinder:
– check the cylinder 1 pencil coil,
– check the condition and conformity of the spark plugs,
– check the cylinder 1 injector
If everything is in order, check the same components on cylinder 4 (to cover a possible
cylinder recognition error).
The fault is probably due to a component that affects a pair of cylinders:
– check the ignition coil circuit concerned (apply the interpretation of fault DF361
Ignition coil control 1-4),
– check the condition and conformity of the spark plugs.
The fault is probably due to a component affecting all the cylinders:
– check that the correct fuel is being used,
– check the condition and conformity of the spark plugs.
If the fault is still present, carry out the following checks:
– check the flywheel sensor,
– check the condition and cleanliness of the flywheel,
– check the flywheel sensor mounting,
– check the sensor/flywheel air gap,
– check the cylinder compressions,
– check the complete fuel system (see MR 364 or 370 Mechanics, 13A, Fuel supply, Petrol supply system),
– check the complete ignition system (see MR 364 or 370 Mechanics, 17A, Ignition, Spark plugs),
– check the hydraulic tappets if there is camshaft noise (see MR 364 or 370 Mechanics, 11A, Top and front of
engine).
If the fault is still present, deal with the other faults then proceed with the conformity check.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.

Page 53 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-53
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-53V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF060
PRESENT
OR
STOREDCOMBUSTION MISFIRING ON CYLINDER 2
1.DEF: Programming of stops
2.DEF: Dephaser mechanically jammed
3.DEF: Servo-control fault
4.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
– ignition: DF361 Ignition coil circuit cylinders 1-4
DF362 Ignition coil circuit cylinders 2-3
– fuel supply circuit:
DF026 Injector control circuit cylinder 1,
DF027 Injector control circuit cylinder 2,
DF028 Injector control circuit cylinder 3,
DF029 Injector control circuit cylinder 4,
DF085 Fuel pump relay control circuit.
– engine flywheel signal: DF154 Flywheel signal sensor circuit
DF457 Flywheel target
Check whether there are other cylinders with a combustion misfire fault detected by the
tool before starting the following fault finding procedure.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present under the following conditions:
– there must be no further electrical faults,
– programming must be carried out.
– warm engine (coolant temperature 75°C minimum),
– engine running at idling speed with all electrical consumers on for approximately
15 minutes.
Special note:
–OBD warning light illuminated.
1.DEF
NOTESSpecial note:
– As soon as the fault is detected, the injection is cut off on
the faulty cylinder(s) to limit the temperature increase in
the catalytic converter,
– if a fault is present, the OBD warning light flashes.
2.DEFSpecial note:
–the OBD warning light remains continuously lit.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF060/S3000_V54_DF060

Page 54 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-54
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-54V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF060
CONTINUED
Combustion
misfires in
cylinder 2 only
Misfires in
cylinders 2 and 3
(see DF060
Misfires in
cylinder 2 and
DF061 Misfires in
cylinder 3)
Combustion
misfires on all
four cylinders
(see DF059, DF060
DF061 and DF062)
The fault is probably due to a component that can only affect this cylinder:
– check the cylinder 2 pencil coil,
– check the condition and conformity of the spark plugs,
– check the cylinder 2 injector.
If everything is in order, check the same components on cylinder 3 (to correct a possible
cylinder identification error).
The fault is probably due to a component that affects a pair of cylinders:
– check the ignition coil circuit concerned (apply the interpretation of fault DF362
Ignition coil control 2-3),
– check the condition and conformity of the spark plugs.
The fault is probably due to a component affecting all the cylinders:
– check that the correct fuel is being used,
– check the condition and conformity of the spark plugs.
If the fault is still present, carry out the following checks:
– check the flywheel sensor,
– check the condition and cleanliness of the flywheel,
– check the flywheel sensor mounting,
– check the sensor/flywheel air gap,
– check the cylinder compressions,
– check the complete fuel system (see MR 364 or 370 Mechanics, 13A, Fuel supply, Petrol supply system),
– check the complete ignition system (see MR 364 or 370 Mechanics, 17A, Ignition, Spark plugs),
– check the hydraulic tappets if there is camshaft noise (see MR 364 or 370 Mechanics, 11A, Top and front of
engine).
If the fault is still present, deal with the other faults then proceed with the conformity check.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.