air condition RENAULT SCENIC 2011 J95 / 3.G Engine And Peripherals EDC16 Injection Repair Manual
Page 99 of 236
13B-99
DIESEL INJECTION
Fault finding - Interpretation of faults
13B
V10 MR-372-J84-13B150$376.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 44, 48 and 4C
DF272
PRESENT
OR
STOREDEGR VALVE CONTROL CIRCUIT
CC.1 : short circuit to + 12 V
CC.0 : short circuit to earth
CO : open circuit
1.DEF : internal electrical fault
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present following a road test or an actuator control AC002 EGR
Solenoid Valve.
Special notes:
The EGR and turbocharging functions are inhibited.
The level 1 warning light comes on.
If CC.0 is still present, the OBD warning light will come on after three consecutive
driving cycles (starting + 5 seconds + switch off the ignition and wait 40 seconds).
Use bornier Elé. 1681 for all operations on the injection computer connectors.
WARNING
If dealing with this fault requires the EGR valve to be replaced, run command RZ002 EGR Adaptives
described in Interpretation of commands in this section.
CC.1
NOTESNone.
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
Measure the resistance of the EGR solenoid valve between tracks 1 and 5.
If the resistance is not approximately 8 Ω ±0.5 at 20°C, replace the EGR valve.
Check the continuity and insulation against + 12 V of the following connection:
Injection computer brown 48-track connector B, track L2 Track 5 of the EGR valve
Repair if necessary.
If the fault is still present, replace the EGR valve
AFTER REPAIRDeal with any faults.
Carry out a road test, then check with the diagnostic tool.
EDC16_V44_DF272/EDC16_V48_DF272/EDC16_V4C_DF272
Page 102 of 236
13B-102
DIESEL INJECTION
Fault finding - Interpretation of faults
13B
V10 MR-372-J84-13B150$376.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 44, 48 and 4C
DF276
PRESENT
OR
STOREDINJECTOR CODE PROGRAMMING
1.DEF : Internal electronic fault during programming
2.DEF : no code stored
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after:
– replacing injector(s),
– replacing the injection computer.
Special notes:
If the fault is present:
– the engine speed is limited,
– the level 1 warning light is lit.
1.DEF
NOTESNone.
Program the injector codes using command SC002 Enter injector codes.
Carry out the procedure described in the Interpretation of commands section.
If the fault is still present, after the ignition is switched off and dialogue is established, contact the Techline.
2.DEF
NOTESThis fault appears on any blank computer (new or
recently reprogrammed).
WARNING
A computer without the IMA option can be replaced by a computer with this option. The codes are not
saved during command SC003 Save computer data.
In this case, status ET104 Injector code use changes to YES or FAULTY, fault DF276 will be present, and
the engine will operate in defect mode.
– Program the injector codes using:
command SC002 Enter injector codes, (follow the procedure described in the Interpretation of commands
section).
– After the codes have been entered:
– switch off the ignition,
– wait until power latch closes down and then switch the ignition back on,
– establish dialogue and clear the fault memory,
– end of operation.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults.
Carry out a road test, then check with the diagnostic tool.
EDC16_V44_DF276/EDC16_V48_DF276/EDC16_V4C_DF276
Page 103 of 236
13B-103
DIESEL INJECTION
Fault finding - Interpretation of faults
13B
V10 MR-372-J84-13B150$376.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 48
DF530
PRESENT
OR
STOREDEGR ADAPTIVES
WARNING
This fault only appears in Vdiag 48.
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– a road test,
– an actuator command AC002 EGR solenoid valve.
Special notes:
The EGR and turbocharging functions are inhibited.
The level 1 warning light comes on.
Use bornier Ele. 1681 for all operations on the injection computer connectors.
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
Clear any stored faults.
Run command RZ002 EGR Adaptives to reinitialise the valve operating values.
Switch off the ignition and wait for the engine immobiliser warning light to start flashing.
Switch the ignition on again and check the system faults.
If the fault is still present, replace the exhaust gas recirculation valve.
AFTER REPAIRDeal with any faults.
Carry out a road test, then check with the diagnostic tool.
EDC16_V48_DF530
Page 104 of 236
13B-104
DIESEL INJECTION
Fault finding - Interpretation of faults
13B
V10 MR-372-J84-13B150$376.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 48 and 4C
DF619
PRESENT
OR
STOREDEGR VALVE JAMMED OPEN
WARNING
This fault only appears in Vdiag 48 and 4c.
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– a road test,
– an actuator command AC002 EGR solenoid valve.
Special notes:
The EGR and turbocharging functions are inhibited.
The level 1 warning light comes on.
Use bornier Ele. 1681 for all operations on the injection computer connectors.
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
Clear any stored faults.
Run command RZ002 EGR Adaptives to reinitialise the valve operating values.
Switch off the ignition and wait for the engine immobiliser warning light to start flashing.
Switch the ignition on again and check the system faults.
If the fault is still present:
– remove the EGR valve and reconnect it after removing it,
– check that the movement of the valve is not being blocked by a particle,
– check that the valve is not jammed or stuck in one position,
– run command AC002 EGR solenoid valve,
– check the movement of the solenoid valve,
– check that the solenoid valve is completely closed,
– if there is no movement, or if the valve is seized and cannot be repaired, replace the EGR solenoid valve.
AFTER REPAIRDeal with any faults.
Carry out a road test, then check with the diagnostic tool.
EDC16_V48_DF619/EDC16_V4C_DF619
Page 105 of 236
13B-105
DIESEL INJECTION
Fault finding - Interpretation of faults
13B
V10 MR-372-J84-13B150$376.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 48
DF620
PRESENT
OR
STOREDEGR VALVE FOULED
WARNING
This fault only appears in Vdiag 48.
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– a road test,
– an actuator command AC002 EGR solenoid valve.
Special notes:
The EGR and turbocharging functions are inhibited.
The level 1 warning light comes on.
Use bornier Ele. 1681 for all operations on the injection computer connectors.
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
Clear any stored faults.
Run command RZ002 EGR Adaptives to reinitialise the valve operating values.
Switch off the ignition and wait for the engine immobiliser warning light to start flashing.
Switch the ignition on again and check the system faults.
If the fault is still present:
– remove the EGR valve, and then reconnect it,
– check that the movement of the valve is not being blocked by a particle,
– check that the valve is not jammed or stuck in one position,
– run command AC002 EGR solenoid valve,
– check the movement of the solenoid valve,
– check that the solenoid valve is completely closed,
– if there is no movement, or if the valve is seized and cannot be repaired, replace the EGR solenoid valve.
AFTER REPAIRDeal with any faults.
Carry out a road test, then check with the diagnostic tool.
EDC16_V44_DF620/EDC16_V48_DF620/EDC16_V4C_DF620
Page 106 of 236
13B-106
DIESEL INJECTION
Fault finding - Interpretation of faults
13B
V10 MR-372-J84-13B150$376.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 48 and 4C
DF621
PRESENT
OR
STOREDEGR VALVE LOCKED OPEN (OBD fault)
WARNING
This fault only appears in Vdiag 48 and 4C.
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– a road test,
– an actuator command AC002 EGR solenoid valve.
Special notes:
The EGR and turbocharging functions are inhibited.
The level 1 warning light comes on.
The OBD warning light will come on after three consecutive driving cycles (starting +
5 seconds + switch off the ignition and wait 40 seconds).
Use bornier Ele. 1681 for all operations on the injection computer connectors.
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
Clear any stored faults.
Run command RZ002 EGR Adaptives to reinitialise the valve operating values.
Switch off the ignition and wait for the engine immobiliser warning light to start flashing.
Switch the ignition on again and check the system faults.
If the fault is still present:
– remove the EGR valve and reconnect it after removing it,
– check that the movement of the valve is not being blocked by a particle,
– check that the valve is not jammed or stuck in one position,
– run command AC002 EGR solenoid valve,
– check the movement of the solenoid valve,
– check that the solenoid valve is completely closed,
– if there is no movement, or if the valve is seized and cannot be repaired, replace the EGR solenoid valve.
AFTER REPAIRDeal with any faults.
Carry out a road test, then check with the diagnostic tool.
EDC16_V48_DF621/EDC16_V4C_DF621
Page 107 of 236
13B-107
DIESEL INJECTION
Fault finding - Interpretation of faults
13B
V10 MR-372-J84-13B150$376.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 4C
DF622
PRESENT
OR
STOREDEGR VALVE JAMMED OPEN
WARNING
This fault only appears in Vdiag 4C.
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– a road test,
– an actuator command AC002 EGR solenoid valve.
Special notes:
The EGR and turbocharging functions are inhibited.
The level 1 warning light comes on.
Use bornier Ele. 1681 for all operations on the injection computer connectors.
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
Clear any stored faults.
Run command RZ002 EGR Adaptives to reinitialise the valve operating values.
Switch off the ignition and wait for the engine immobiliser warning light to start flashing.
Switch the ignition on again and check the system faults.
If the fault is still present:
– remove the EGR valve and reconnect it after removing it,
– check that the movement of the valve is not being blocked by a particle,
– check that the valve is not jammed or stuck in one position,
– run command AC002 EGR solenoid valve,
– check the movement of the solenoid valve,
– check that the solenoid valve is completely closed,
– if there is no movement, or if the valve is seized and cannot be repaired, replace the EGR solenoid valve.
AFTER REPAIRDeal with any faults.
Carry out a road test, then check with the diagnostic tool.
EDC16_V4C_DF622
Page 108 of 236
13B-108
DIESEL INJECTION
Fault finding - Interpretation of faults
13B
V10 MR-372-J84-13B150$376.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 44, 48 and 4C
DF1070
PRESENT
OR
STOREDCOLD LOOP
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present with the engine running and a heating and air
conditioning request
Priorities when dealing with a number of faults:
Firstly, deal with the following faults:
– DF049 Refrigerant sensor circuit if it is present or stored.
When the fault is present or stored, the heating and air conditioning system is inhibited.
Check fuse F22 (10A) of the UPC and the condition of the air conditioning compressor connector.
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the air conditioning compressor wiring.
If the wiring is faulty and there is a repair procedure (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
Manually check if the compressor is jammed (turn the clutch plate manually to check that there is no point of
resistance). In the event of sticking, replace the air conditioning compressor (see MR 364 (Mégane II) or 370
(Scénic II), Mechanical, Heating and air conditioning system, 62A, Air conditioning, Compressor: Removal
- Refitting).
Top up with freon, check for any leaks and repair if necessary (see MR 364 (Mégane II) or 370 (Scénic II),
Mechanical, Heating and air conditioning system, 62A, Air conditioning, Refrigerant circuit: check,
Refrigerant circuit: Draining - Filling).
AFTER REPAIRDeal with any faults.
Carry out a road test, then check with the diagnostic tool.
EDC16_V44_DF1070/EDC16_V48_DF1070/EDC16_V4C_DF1070
Page 110 of 236
13B-110
DIESEL INJECTION
Fault finding - Conformity check13B
V10 MR-372-J84-13B150$423.mif
EDC16 INJECTION
Program No.: C1
Vdiag No: 44, 48 and 4C
MAIN COMPUTER STATUSES AND PARAMETERS (continued)
NOTESOnly carry out this conformity check after carrying out a complete check using the
diagnostic tool. The values shown in this conformity check are given as examples.
Test conditions: engine stopped, ignition on.
Order FunctionParameter or Status
Check or ActionDisplay and Notes Fault finding
5 PressurePR035:Atmospheric
pressureIndicates the
atmospheric pressure
in mbar.
The sensor is built into
the computer.
Default value:
750 mbarIn the event of a fault,
consult the interpretation
of fault DF003 Atmospheric
pressure sensor circuit.
PR038:Rail pressure0 <X <2barIn the event of a fault,
consult the interpretation
of fault DF007 Rail pressure
sensor circuit.
6 TemperaturePR059: Inlet air
temperatureIndicates the inlet air
temperature
Ignition on
PR061 = PR059
Default value: 20°C In the event of a fault, refer
to the interpretation
of parameter PR059.
PR064: Coolant
temperatureShows the engine
coolant temperature
in °C
Default value: 119°C.In the event of a fault,
refer to the interpretation
ofDF001 Coolant
temperature sensor
circuit.
7 Preheating ET007: Pre-postheating
controlINACTIVE
or
ACTIVEIn the event of a fault,
refer to the interpretation
of statusET007.
8 Torque PR015: Engine torqueX = 0 NmNone.
9Charging
circuit PR016:Alternator flow X = 0 mAIn the event of a fault,
check the charge circuit.
Page 112 of 236
13B-112
DIESEL INJECTION
Fault finding - Conformity check13B
V10 MR-372-J84-13B150$423.mif
EDC16 INJECTION
Program No.: C1
Vdiag No: 44, 48 and 4C
AIR CIRCULATION (TURBOCHARGING/INLET)
NOTESOnly carry out this conformity check after carrying out a complete check using the
diagnostic tool. The values shown in this conformity check are given as examples.
Test conditions: engine stopped, ignition on.
Order FunctionParameter or Status
Check or ActionDisplay and Notes Fault finding
1 Engine speed PR055:Engine speedIndicates the engine's
speed of rotation in
rpm. With the ignition
on PR55 = 0 rpm.In the event of a fault,
refer to the interpretation
of fault DF005 Engine
speed sensor circuit.
2 TemperaturePR061:Exterior air
temperatureGives the exterior air
temperature in °C. This
parameter is managed
by the UCH and
transmitted to the
injection on the
multiplex network.
Default value: 20°CIn the event of a fault,
(see 87B carry out fault
finding on the UCH).
PR059:Inlet air
temperatureIgnition on
Default value: 20°C
PR061 = PR059In the event of a fault,
refer to the interpretation
of fault DF039 Inlet air
temperature sensor
circuit.
3 TurbochargingPR041:Turbocharging
pressurePR041 = PR035 =
Atmospheric
pressureIn the event of a fault,
consult the interpretation
of fault DF004
Turbocharging pressure
sensor circuit.
PR009:Turbocharging
pressure
setpoint790 < X < 1010 mbarNone.
PR047:Turbocharging
pressure OCRX= 5%
The opening cyclic ratio
should be identical to the
correction of the solenoid
valve position. PR011:Turbocharging
solenoid valve
position sensorX= 5%