RENAULT TWINGO 2009 2.G Electrical Equipment - Electric Windows, Sunroof Workshop Manual

Page 1 of 54

Electrical equipment
"The repair procedures given by the manufacturer in this document are based on the
technical specifications current when it was prepared.
The procedures may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from
which his vehicles are constructed."
V1
All rights reserved by Renault s.a.s.
Edition Anglaise
Copying or translating, in part or in full, of this document or use of the service part
reference numbering system is forbidden without the prior written authority of
Renault s.a.s.
© Renault s.a.s.
V1 MR-413-X44-87D000$000_engTOC.mif
ELECTRIC WINDOWS - SUNROOF
Electric window: List and location of components 87D - 2
Electric windows: Role of components 87D - 3
Electric windows: Operating diagram 87D - 4
Electric windows: Function 87D - 5
Electric windows: Defect and safe modes 87D - 6
Electric windows: Initialisation 87D - 7
Electric window fault finding - Customer complaints 87D - 8
Electric windows - Fault finding chart 87D - 9
Electric windows: List and location of components 87D - 36
Electric sunroof: Component functions 87D - 37
Electric sunroof: Operating diagram 87D - 38
Electric sunroof: Function 87D - 39
Electric sunroof: Defect and safe modes 87D - 40
Electric sunroof: Initialisation 87D - 41
Electric sunroof fault finding - Customer complaints 87D - 42
Electric sunroof - Fault finding chart 87D - 43
87D
MR-413-X44-87D000$000_engTOC.mif

Page 2 of 54

87D-2
MR-413-X44-87D000$059_eng.mif
V1
87D
ELECTRIC WINDOWS - SUNROOF
Electric window: List and location of components
Electric window switch plate on driver's side:
1Driver's electric window switch
2Passenger electric window switch
Electric window switch plate on passenger's side:
3Passenger electric window switchUCH
1
2
3

New Twingo
MR-413-X44-87D000$059_eng.mif

Page 3 of 54

87D-3
MR-413-X44-87D000$118_eng.mif
V1
87D
ELECTRIC WINDOWS - SUNROOF
Electric windows: Role of components
●The control panel on the driver's side enables all of the windows to be opened or closed (on the driver's and
passenger's side).
●The passenger electric window switch only lowers or raises the window on the passenger side.
●The UCH controls the operation of the one-touch and anti-pinch control windows.
●The electric window winder motor enables the window to be opened or closed.

New Twingo
MR-413-X44-87D000$118_eng.mif

Page 4 of 54

87D-4
MR-413-X44-87D000$177_eng.mif
V1
87D
ELECTRIC WINDOWS - SUNROOF
Electric windows: Operating diagram
ONE-TOUCH ELECTRIC WINDOWS (with anti-pinch)
1Driver's electric window switch
2Passenger's electric window switch
3Electric window winder motor with electronic unit (computer) controlling one-touch and anti-pinch functions
4Simple electric window winder motor without a computer
5UCH (authorisation to operate with multifunction connection)
Note:
The one-touch electric window switch is different from the electric window switches.
1
1
2
3
5
4

New Twingo
MR-413-X44-87D000$177_eng.mif

Page 5 of 54

87D-5
MR-413-X44-87D000$236_eng.mif
V1
87D
ELECTRIC WINDOWS - SUNROOF
Electric windows: Function
Types
The vehicle can be fitted with two types of front window winders:
–Driver's and passengers' electric windows.
–Driver's anti-pinch and one-touch electric window / passenger's electric window.
Electric windows
The motor feed goes via the switch. The switch reverses the polarity to the motor terminals to lower or raise the
window.
One-touch electric window
The UCH controls this window, both its upward and downward movement, in manual or automatic mode (one-touch).
The UCH can only be controlled by unstable position switches (one up position, one down position). The electrical
signal received by the unit means that the input used is connected to earth.
The switch technology employed means that automatic mode cannot be activated directly (double contact
technology). That is why the electric window switches have two up positions (contacts) and two down positions
(contacts).
Electric mode is activated first (1
st contact) followed by one-touch mode (2nd contact). The direction of movement of
the window is determined by the first input (connection to earth).
First example
Switch pressed in the down direction:
1
st contact = down switch earthed
2nd contact = up switch earthed
The electronic unit activates lowering of the window in one-touch mode.
Second example
Switch pressed in the up direction:
1
st contact = up switch earthed
2nd contact = down switch earthed
The electronic unit activates raising of the window in one-touch mode.
ANTI-PINCH
The anti-pinch function is a statutory requirement, which is also managed by the electronic unit. This stops the
window rising in one-touch mode when it meets an obstacle (e.g. fingers, branches, etc.)
On detecting an abnormal force (more than 80N) in a 250 mm area (between the upper stop of the window and the
window), the system causes the window to lower approximately 50 mm.
WARNING
The anti-pinch function only works if the windows have been correctly initialised (see Initialisation).

New Twingo
MR-413-X44-87D000$236_eng.mif

Page 6 of 54

87D-6
MR-413-X44-87D000$295_eng.mif
V1
87D
ELECTRIC WINDOWS - SUNROOF
Electric windows: Defect and safe modes
INHIBITING THE ANTI-PINCH FUNCTION
The window or window mechanism may be subject to various mechanical problems (jammed by ice, snow or
mechanical distortion due to an accident), which can trigger the anti-pinch function. It is possible to inhibit this
function so that the window can be closed.
Procedure:
1) Closing the window in one-touch mode. The window arrives at the point of resistance, then drops back a few
centimetres.
2) Close the window in one-touch mode. The window arrives at the point of resistance again, then drops back a few
centimetres.
3) Close the window, the anti-pinch function is inhibited. The window closes in manual mode continuously without
the anti-pinch function.

New Twingo
MR-413-X44-87D000$295_eng.mif

Page 7 of 54

87D-7
MR-413-X44-87D000$354_eng.mif
V1
87D
ELECTRIC WINDOWS - SUNROOF
Electric windows: Initialisation
Procedure:
Raise the window to the upper limit and maintain the feed at the upper stop for at least 2 seconds.
Causes of loss of initialisation:
–The electronic unit feed is cut off while the electric window is operating or when the UCH is authorising the
operation.
–The theoretical maximum travel goes beyond the upper stop.
–If the correct position was not initialised (obstacle), operation of the window beyond that point will be in jerks
(50 mm stages). WARNING
To obtain one-touch mode and/or manual mode operation (opening and closing) and the anti-pinch function, the
electronic system built into the motor must be correctly initialised.
Note:
A non-initialised system will function while the control switch is pressed, but the window will only travel a
maximum of 50 mm. Every time the switch is pressed the window will travel a similar distance until it reaches the
top stop.

New Twingo
MR-413-X44-87D000$354_eng.mif

Page 8 of 54

87D-8
MR-413-X44-87D000$413_eng.mif
V1
87D
ELECTRIC WINDOWS - SUNROOF
Electric window fault finding - Customer complaints
NOTESOnly refer to these customer complaints after performing a complete check with the
diagnostic tool.
DRIVER AND PASSENGER ELECTRIC WINDOWS
NO ELECTRIC WINDOW OPERATION ALP 1
ONLY THE DRIVER'S WINDOW DOES NOT OPERATE AT ALL ALP 2
THE PASSENGER WINDOW DOES NOT OPERATE AT ALL WITH THE
PASSENGER SWITCH ONLYALP 3
THE PASSENGER WINDOW DOES NOT OPERATE AT ALL WITH ANY SWITCHALP 4
DRIVER'S ONE-TOUCH ELECTRIC WINDOWS
AND PASSENGER ELECTRIC WINDOW
ONLY THE DRIVER'S WINDOW DOES NOT OPERATE AT ALL ALP 5
THE PASSENGER WINDOW DOES NOT OPERATE AT ALL WITH THE
DRIVER'S SWITCH ONLYALP 6
THE PASSENGER WINDOW DOES NOT OPERATE AT ALL WITH ANY SWITCHALP 7
THE PASSENGER WINDOW DOES NOT OPERATE AT ALL WITH THE
PASSENGER SWITCH ONLYALP 8
DRIVER'S WINDOW RISES JERKILY IN 50 MM STAGES ALP 9

New Twingo
MR-413-X44-87D000$413_eng.mif

Page 9 of 54

87D-9
MR-413-X44-87D000$472_eng.mif
V1
87D
ELECTRIC WINDOWS - SUNROOF
Electric windows - Fault finding chart
ALP 1 No electric window operation
Applies to:Driver and passenger electric windows
Left-hand drive vehicle
NOTESUse Wiring Diagram Technical Note, New Twingo.
Carry out the various checks with the battery charged and + after ignition feed
switched on.
Check that the fuses are sound.
Use a 21 W test light.
Remove the driver's window switch (see MR 411
mechanical systems, 87D, Electric windows -
Sunroof, driver's door front electric window
switch: Removal - Refitting) and disconnect its
connector.
Connect a test light between connection SPB3
and the earth MAM of component 1512. Pay
close attention to the intermediate connector.
Does the test light illuminate?
YES
Shunt connection SPB3 with 21A and MAM with
21B to lower the window (to raise the window
SPB3 with 21B and 21A with MAM), on the
connector of component 1512.
Does the window move?
YES
Replace the driver's window winder switch (see
MR 411 mechanical, 87D, Electric windows -
Sunroof, Driver's door front window winder
switch: Removal - Refitting).
Connect the test light between
connection SPB3 and the chassis
earth.
Does the test light illuminate?
YES
Check that the earth MAM of
component 1512 is correctly mounted
on the chassis. If the earth is faulty,
clean and retighten it.
Otherwise the fault is caused by the
wiring; if there is a repair procedure
(see Technical Note 6015A,
Repairing electrical wiring, W iring:
Precautions for repair), repair the
wiring; if not, replace it.NO
NO
NO
AFTER REPAIRCheck that the electric windows are operating correctly; if not, run fault finding
(see Customer complaints).
AB

New Twingo
MR-413-X44-87D000$472_eng.mif

Page 10 of 54

87D-10
MR-413-X44-87D000$472_eng.mif
V1

New TwingoELECTRIC WINDOWS - SUNROOF
Electric windows - Fault finding chart87D
ALP 1
CONTINUED
Connect a test light between connections 21B
and 21A of component 203.
Reconnect the electric window switch and
operate it. Does the test light illuminate?
YES
Replace the driver's window winder motor
(see MR 412 bodywork, 51A, Side opening
element mechanisms, Front side door electric
window mechanism:
Removal - Refitting).
NOContinuity fault on connection SPB3 between
components 1512 and 1016.
Pay close attention to the intermediate
connector.
If there is a repair procedure (see Technical
Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the
wiring, otherwise replace it.
Continuity fault on connections 21A and/
or 21B between components 1512 and
203.
If there is a repair procedure (see Technical
Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the
wiring, otherwise replace it.
Run fault finding using ALP 4.
AFTER REPAIRCheck that the electric windows are operating correctly; if not, run fault finding
(see Customer complaints).